FHIR CI-Build

This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions icon

Orders and Observations icon Work GroupMaturity Level: N/A  Trial UseSecurity Category: Patient Compartments: Device, Encounter, Patient, Practitioner

Search parameters for the Resource DeviceRequest - Search Parameters resource. Also check the Extensions registry for search parameters on extensions related to this resource.

The common parameters also apply. See Searching for more information about searching in REST, messaging, and services.


http://hl7.org/fhir/SearchParameter/DeviceRequest-authored-on

Parameter authored-on:date

When the request transitioned to being actionable

ResourceDeviceRequest
ExpressionDeviceRequest.authoredOn
Processing ModeNormal
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
ComparatorsAllowed: eq, ne, gt, ge, lt, le, sa, eb, ap
 
http://hl7.org/fhir/SearchParameter/DeviceRequest-based-on

Parameter based-on:reference

Plan/proposal/order fulfilled by this request

ResourceDeviceRequest
ExpressionDeviceRequest.basedOn
Processing ModeNormal
Target ResourcesAccount, ActivityDefinition, ActorDefinition, AdministrableProductDefinition, AdverseEvent, AllergyIntolerance, Appointment, AppointmentResponse, ArtifactAssessment, AuditEvent, Basic, Binary, BiologicallyDerivedProduct, BiologicallyDerivedProductDispense, BodyStructure, Bundle, CapabilityStatement, CarePlan, CareTeam, ChargeItem, ChargeItemDefinition, Citation, Claim, ClaimResponse, ClinicalImpression, ClinicalUseDefinition, CodeSystem, Communication, CommunicationRequest, CompartmentDefinition, Composition, ConceptMap, Condition, ConditionDefinition, Consent, Contract, Coverage, CoverageEligibilityRequest, CoverageEligibilityResponse, DetectedIssue, Device, DeviceAssociation, DeviceDefinition, DeviceDispense, DeviceMetric, DeviceRequest, DeviceUsage, DiagnosticReport, DocumentReference, Encounter, EncounterHistory, Endpoint, EnrollmentRequest, EnrollmentResponse, EpisodeOfCare, EventDefinition, Evidence, EvidenceReport, EvidenceVariable, ExampleScenario, ExplanationOfBenefit, FamilyMemberHistory, Flag, FormularyItem, GenomicStudy, Goal, GraphDefinition, Group, GuidanceResponse, HealthcareService, ImagingSelection, ImagingStudy, Immunization, ImmunizationEvaluation, ImmunizationRecommendation, ImplementationGuide, Ingredient, InsurancePlan, InventoryItem, InventoryReport, Invoice, Library, Linkage, List, Location, ManufacturedItemDefinition, Measure, MeasureReport, Medication, MedicationAdministration, MedicationDispense, MedicationKnowledge, MedicationRequest, MedicationStatement, MedicinalProductDefinition, MessageDefinition, MessageHeader, MolecularSequence, NamingSystem, NutritionIntake, NutritionOrder, NutritionProduct, Observation, ObservationDefinition, OperationDefinition, OperationOutcome, Organization, OrganizationAffiliation, PackagedProductDefinition, Parameters, Patient, PaymentNotice, PaymentReconciliation, Permission, Person, PlanDefinition, Practitioner, PractitionerRole, Procedure, Provenance, Questionnaire, QuestionnaireResponse, RegulatedAuthorization, RelatedPerson, RequestOrchestration, Requirements, ResearchStudy, ResearchSubject, RiskAssessment, Schedule, SearchParameter, ServiceRequest, Slot, Specimen, SpecimenDefinition, StructureDefinition, StructureMap, Subscription, SubscriptionStatus, SubscriptionTopic, Substance, SubstanceDefinition, SubstanceNucleicAcid, SubstancePolymer, SubstanceProtein, SubstanceReferenceInformation, SubstanceSourceMaterial, SupplyDelivery, SupplyRequest, Task, TerminologyCapabilities, TestPlan, TestReport, TestScript, Transport, ValueSet, VerificationResult, VisionPrescription
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/clinical-code
This search parameter is part of the common search parameter clinical-code

Parameter code:token

DeviceRequest: Code for what is being requested/ordered

ResourceDeviceRequest
ExpressionDeviceRequest.code.concept
Processing ModeNormal
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceRequest-device

Parameter device:reference

Reference to resource that is being requested/ordered

ResourceDeviceRequest
ExpressionDeviceRequest.code.reference
Processing ModeNormal
Target ResourcesDevice, DeviceDefinition
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/clinical-encounter
This search parameter is part of the common search parameter clinical-encounter

Parameter encounter:reference

DeviceRequest: Encounter during which request was created

ResourceDeviceRequest
ExpressionDeviceRequest.encounter
Processing ModeNormal
Target ResourcesEncounter
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceRequest-event-date

Parameter event-date:date

When service should occur

ResourceDeviceRequest
Expression(DeviceRequest.occurrence.ofType(dateTime)) | (DeviceRequest.occurrence.ofType(Period))
Processing ModeNormal
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
ComparatorsAllowed: eq, ne, gt, ge, lt, le, sa, eb, ap
 
http://hl7.org/fhir/SearchParameter/DeviceRequest-group-identifier

Parameter group-identifier:token

Composite request this is part of

ResourceDeviceRequest
ExpressionDeviceRequest.groupIdentifier
Processing ModeNormal
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/clinical-identifier
This search parameter is part of the common search parameter clinical-identifier

Parameter identifier:token

DeviceRequest: Business identifier for request/order

ResourceDeviceRequest
ExpressionDeviceRequest.identifier
Processing ModeNormal
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceRequest-instantiates-canonical

Parameter instantiates-canonical:reference

Instantiates FHIR protocol or definition

ResourceDeviceRequest
ExpressionDeviceRequest.instantiatesCanonical
Processing ModeNormal
Target ResourcesActivityDefinition, PlanDefinition
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceRequest-instantiates-uri

Parameter instantiates-uri:uri

Instantiates external protocol or definition

ResourceDeviceRequest
ExpressionDeviceRequest.instantiatesUri
Processing ModeNormal
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceRequest-insurance

Parameter insurance:reference

Associated insurance coverage

ResourceDeviceRequest
ExpressionDeviceRequest.insurance
Processing ModeNormal
Target ResourcesClaimResponse, Coverage
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceRequest-intent

Parameter intent:token

proposal | plan | original-order |reflex-order

ResourceDeviceRequest
ExpressionDeviceRequest.intent
Processing ModeNormal
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/clinical-patient
This search parameter is part of the common search parameter clinical-patient

Parameter patient:reference

DeviceRequest: Individual the service is ordered for

ResourceDeviceRequest
ExpressionDeviceRequest.subject.where(resolve() is Patient)
Processing ModeNormal
Target ResourcesPatient
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceRequest-performer

Parameter performer:reference

Desired performer for service

ResourceDeviceRequest
ExpressionDeviceRequest.performer.reference
Processing ModeNormal
Target ResourcesHealthcareService, Organization, CareTeam, Device, RelatedPerson, PractitionerRole, Practitioner, Patient
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceRequest-performer-code

Parameter performer-code:token

Desired performer for service

ResourceDeviceRequest
ExpressionDeviceRequest.performer.concept
Processing ModeNormal
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceRequest-prior-request

Parameter prior-request:reference

Request takes the place of referenced completed or terminated requests

ResourceDeviceRequest
ExpressionDeviceRequest.replaces
Processing ModeNormal
Target ResourcesDeviceRequest
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceRequest-requester

Parameter requester:reference

Who/what is requesting service

ResourceDeviceRequest
ExpressionDeviceRequest.requester
Processing ModeNormal
Target ResourcesDevice, Organization, PractitionerRole, Practitioner
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceRequest-status

Parameter status:token

entered-in-error | draft | active |suspended | completed

ResourceDeviceRequest
ExpressionDeviceRequest.status
Processing ModeNormal
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceRequest-subject

Parameter subject:reference

Individual the service is ordered for

ResourceDeviceRequest
ExpressionDeviceRequest.subject
Processing ModeNormal
Target ResourcesDevice, Group, Location, Patient
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true