Blood Pressure Cross-Country Cross-Language Cross-Paradigm (Demo) IG
0.2.1 - ci-build
Blood Pressure Cross-Country Cross-Language Cross-Paradigm (Demo) IG, published by FO. This guide is not an authorized publication; it is the continuous build for version 0.2.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/frankoemig/bloodpressure/ and changes regularly. See the Directory of published versions
Official URL: http://bloodpressure.oemig.de/fhir/StructureDefinition/BloodPressure | Version: 0.2.1 | |||
Active as of 2024-04-16 | Computable Name: BloodPressure | |||
Copyright/Legal: FO |
This is the Logical Model for Blood Pressure
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
BloodPressure | 0..* | Base | Blood Pressure LM Instances of this logical model are not marked to be the target of a Reference | |
systolicPressure | Σ | 0..1 | BackboneElement | systolic blood pressure ele-1: All FHIR elements must have a @value or children |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Systolic Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range ele-1: All FHIR elements must have a @value or children | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
diastolicPressure | Σ | 0..1 | BackboneElement | diastolic blood pressure ele-1: All FHIR elements must have a @value or children |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Diastolic Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range ele-1: All FHIR elements must have a @value or children | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
meanArterialPressure | 0..1 | BackboneElement | mean arterial blood pressure ele-1: All FHIR elements must have a @value or children | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Mean Arterial Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range ele-1: All FHIR elements must have a @value or children | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
pulsePressure | 0..1 | BackboneElement | pulse blood pressure ele-1: All FHIR elements must have a @value or children | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Pulse Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range ele-1: All FHIR elements must have a @value or children | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
interpretation | Σ | 0..1 | CodeableConcept | overall clinical meaning of the BP measurement Binding: Interpretation (required) |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
range | 0..* | BackboneElement | reference range | |
effective[x] | Σ | 0..1 | date of observation | |
effectiveDate | date | |||
effectiveInstant | instant | |||
effectivePeriod | Period | |||
cuffType | 0..1 | CodeableConcept | type of cuff used (eg. rusable, disposable) Binding: Cuff Type (required) | |
cuffSize | 0..1 | CodeableConcept | size of cuff (eg. adult, child) Binding: Cuff Size (required) | |
position | 0..1 | CodeableConcept | position for measurement Binding: Position (required) | |
location | 0..1 | CodeableConcept | body location of measurement Binding: Location (required) | |
consciousness | 0..1 | CodeableConcept | Consciousness of the patient Binding: Consciousness (required) | |
exertion[x] | 0..1 | physical activity (measured in Watts or as coded information) | ||
exertionInteger | integer | |||
exertionCodeableConcept | CodeableConcept | |||
anaesthesia | 0..1 | CodeableConcept | Anaesthesia of patient during measurement Binding: Anaesthesia (required) | |
measurementSetting | 0..1 | CodeableConcept | The setting in which the measurement was performed; i.e. at home, at clinic, at emergency room, etc. Binding: Measurement Setting value set (extensible) | |
medication[x] | 0..1 | medication to be considered, minimum is the indication that there is some kind of medication | ||
medicationBoolean | boolean | |||
medicationReference | Reference(MedicationStatement) | |||
method | 0..1 | CodeableConcept | measurement method | |
tilt | 0..1 | integer | tilt (in degrees) | |
comment | 0..1 | string | any comment | |
subject | 0..1 | Reference(Patient) | reference to the subject of the measurement | |
author | 0..1 | Reference(Practitioner) | reference to the author of the measurement | |
performer | 0..1 | Reference(Practitioner) | reference to the performer of the measurement | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
BloodPressure.systolicPressure.code | extensible | USCoreSystolicBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code from this IG | |
BloodPressure.systolicPressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.systolicPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.systolicPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.diastolicPressure.code | extensible | USCoreDiastolicBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code from this IG | |
BloodPressure.diastolicPressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.diastolicPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.diastolicPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.meanArterialPressure.code | extensible | USCoreMeanArterialBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code from this IG | |
BloodPressure.meanArterialPressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.meanArterialPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.meanArterialPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.pulsePressure.code | extensible | USCorePulseBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code from this IG | |
BloodPressure.pulsePressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.pulsePressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.pulsePressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.cuffType | required | CuffType (a valid code from Cuff Type)http://bloodpressure.oemig.de/fhir/ValueSet/CuffType from this IG | |
BloodPressure.cuffSize | required | CuffSize (a valid code from Cuff Size)http://bloodpressure.oemig.de/fhir/ValueSet/CuffSize from this IG | |
BloodPressure.position | required | Positionhttp://bloodpressure.oemig.de/fhir/ValueSet/Position from this IG | |
BloodPressure.location | required | Locationhttp://bloodpressure.oemig.de/fhir/ValueSet/Location from this IG | |
BloodPressure.consciousness | required | Consciousnesshttp://bloodpressure.oemig.de/fhir/ValueSet/Consciousness from this IG | |
BloodPressure.anaesthesia | required | Anaesthesiahttp://bloodpressure.oemig.de/fhir/ValueSet/Anaesthesia from this IG | |
BloodPressure.measurementSetting | extensible | MeasurementSettingVShttp://bloodpressure.oemig.de/fhir/ValueSet/MeasurementSetting from this IG |
Id | Grade | Path(s) | Details | Requirements |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
shall-be-under-1000-mmHg | error | BloodPressure.systolicPressure.value, BloodPressure.diastolicPressure.value, BloodPressure.meanArterialPressure.value, BloodPressure.pulsePressure.value | Value SHALL be <1000 mmHg for valid data. : $this < 1000 |
This structure is derived from Base
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
BloodPressure | 0..* | Base | Blood Pressure LM Instances of this logical model are not marked to be the target of a Reference | |
systolicPressure | Σ | 0..1 | BackboneElement | systolic blood pressure |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Systolic Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range | |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
diastolicPressure | Σ | 0..1 | BackboneElement | diastolic blood pressure |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Diastolic Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range | |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
meanArterialPressure | 0..1 | BackboneElement | mean arterial blood pressure | |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Mean Arterial Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range | |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
pulsePressure | 0..1 | BackboneElement | pulse blood pressure | |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Pulse Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range | |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
interpretation | Σ | 0..1 | CodeableConcept | overall clinical meaning of the BP measurement Binding: Interpretation (required) |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
range | 0..* | BackboneElement | reference range | |
effective[x] | Σ | 0..1 | date of observation | |
effectiveDate | date | |||
effectiveInstant | instant | |||
effectivePeriod | Period | |||
cuffType | 0..1 | CodeableConcept | type of cuff used (eg. rusable, disposable) Binding: Cuff Type (required) | |
cuffSize | 0..1 | CodeableConcept | size of cuff (eg. adult, child) Binding: Cuff Size (required) | |
position | 0..1 | CodeableConcept | position for measurement Binding: Position (required) | |
location | 0..1 | CodeableConcept | body location of measurement Binding: Location (required) | |
consciousness | 0..1 | CodeableConcept | Consciousness of the patient Binding: Consciousness (required) | |
exertion[x] | 0..1 | physical activity (measured in Watts or as coded information) | ||
exertionInteger | integer | |||
exertionCodeableConcept | CodeableConcept | |||
anaesthesia | 0..1 | CodeableConcept | Anaesthesia of patient during measurement Binding: Anaesthesia (required) | |
measurementSetting | 0..1 | CodeableConcept | The setting in which the measurement was performed; i.e. at home, at clinic, at emergency room, etc. Binding: Measurement Setting value set (extensible) | |
medication[x] | 0..1 | medication to be considered, minimum is the indication that there is some kind of medication | ||
medicationBoolean | boolean | |||
medicationReference | Reference(MedicationStatement) | |||
method | 0..1 | CodeableConcept | measurement method | |
tilt | 0..1 | integer | tilt (in degrees) | |
comment | 0..1 | string | any comment | |
subject | 0..1 | Reference(Patient) | reference to the subject of the measurement | |
author | 0..1 | Reference(Practitioner) | reference to the author of the measurement | |
performer | 0..1 | Reference(Practitioner) | reference to the performer of the measurement | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
BloodPressure.systolicPressure.code | extensible | USCoreSystolicBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code from this IG | |
BloodPressure.systolicPressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.systolicPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.systolicPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.diastolicPressure.code | extensible | USCoreDiastolicBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code from this IG | |
BloodPressure.diastolicPressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.diastolicPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.diastolicPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.meanArterialPressure.code | extensible | USCoreMeanArterialBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code from this IG | |
BloodPressure.meanArterialPressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.meanArterialPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.meanArterialPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.pulsePressure.code | extensible | USCorePulseBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code from this IG | |
BloodPressure.pulsePressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.pulsePressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.pulsePressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.cuffType | required | CuffType (a valid code from Cuff Type)http://bloodpressure.oemig.de/fhir/ValueSet/CuffType from this IG | |
BloodPressure.cuffSize | required | CuffSize (a valid code from Cuff Size)http://bloodpressure.oemig.de/fhir/ValueSet/CuffSize from this IG | |
BloodPressure.position | required | Positionhttp://bloodpressure.oemig.de/fhir/ValueSet/Position from this IG | |
BloodPressure.location | required | Locationhttp://bloodpressure.oemig.de/fhir/ValueSet/Location from this IG | |
BloodPressure.consciousness | required | Consciousnesshttp://bloodpressure.oemig.de/fhir/ValueSet/Consciousness from this IG | |
BloodPressure.anaesthesia | required | Anaesthesiahttp://bloodpressure.oemig.de/fhir/ValueSet/Anaesthesia from this IG | |
BloodPressure.measurementSetting | extensible | MeasurementSettingVShttp://bloodpressure.oemig.de/fhir/ValueSet/MeasurementSetting from this IG |
Id | Grade | Path(s) | Details | Requirements |
shall-be-under-1000-mmHg | error | BloodPressure.systolicPressure.value, BloodPressure.diastolicPressure.value, BloodPressure.meanArterialPressure.value, BloodPressure.pulsePressure.value | Value SHALL be <1000 mmHg for valid data. : $this < 1000 |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
BloodPressure | 0..* | Base | Blood Pressure LM Instances of this logical model are not marked to be the target of a Reference | |
systolicPressure | Σ | 0..1 | BackboneElement | systolic blood pressure |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Systolic Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
diastolicPressure | Σ | 0..1 | BackboneElement | diastolic blood pressure |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Diastolic Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
meanArterialPressure | 0..1 | BackboneElement | mean arterial blood pressure | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Mean Arterial Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
pulsePressure | 0..1 | BackboneElement | pulse blood pressure | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Pulse Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
interpretation | Σ | 0..1 | CodeableConcept | overall clinical meaning of the BP measurement Binding: Interpretation (required) |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
range | 0..* | BackboneElement | reference range | |
effective[x] | Σ | 0..1 | date of observation | |
effectiveDate | date | |||
effectiveInstant | instant | |||
effectivePeriod | Period | |||
cuffType | 0..1 | CodeableConcept | type of cuff used (eg. rusable, disposable) Binding: Cuff Type (required) | |
cuffSize | 0..1 | CodeableConcept | size of cuff (eg. adult, child) Binding: Cuff Size (required) | |
position | 0..1 | CodeableConcept | position for measurement Binding: Position (required) | |
location | 0..1 | CodeableConcept | body location of measurement Binding: Location (required) | |
consciousness | 0..1 | CodeableConcept | Consciousness of the patient Binding: Consciousness (required) | |
exertion[x] | 0..1 | physical activity (measured in Watts or as coded information) | ||
exertionInteger | integer | |||
exertionCodeableConcept | CodeableConcept | |||
anaesthesia | 0..1 | CodeableConcept | Anaesthesia of patient during measurement Binding: Anaesthesia (required) | |
measurementSetting | 0..1 | CodeableConcept | The setting in which the measurement was performed; i.e. at home, at clinic, at emergency room, etc. Binding: Measurement Setting value set (extensible) | |
medication[x] | 0..1 | medication to be considered, minimum is the indication that there is some kind of medication | ||
medicationBoolean | boolean | |||
medicationReference | Reference(MedicationStatement) | |||
method | 0..1 | CodeableConcept | measurement method | |
tilt | 0..1 | integer | tilt (in degrees) | |
comment | 0..1 | string | any comment | |
subject | 0..1 | Reference(Patient) | reference to the subject of the measurement | |
author | 0..1 | Reference(Practitioner) | reference to the author of the measurement | |
performer | 0..1 | Reference(Practitioner) | reference to the performer of the measurement | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
BloodPressure.systolicPressure.code | extensible | USCoreSystolicBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code from this IG | |
BloodPressure.systolicPressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.systolicPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.systolicPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.diastolicPressure.code | extensible | USCoreDiastolicBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code from this IG | |
BloodPressure.diastolicPressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.diastolicPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.diastolicPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.meanArterialPressure.code | extensible | USCoreMeanArterialBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code from this IG | |
BloodPressure.meanArterialPressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.meanArterialPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.meanArterialPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.pulsePressure.code | extensible | USCorePulseBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code from this IG | |
BloodPressure.pulsePressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.pulsePressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.pulsePressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.cuffType | required | CuffType (a valid code from Cuff Type)http://bloodpressure.oemig.de/fhir/ValueSet/CuffType from this IG | |
BloodPressure.cuffSize | required | CuffSize (a valid code from Cuff Size)http://bloodpressure.oemig.de/fhir/ValueSet/CuffSize from this IG | |
BloodPressure.position | required | Positionhttp://bloodpressure.oemig.de/fhir/ValueSet/Position from this IG | |
BloodPressure.location | required | Locationhttp://bloodpressure.oemig.de/fhir/ValueSet/Location from this IG | |
BloodPressure.consciousness | required | Consciousnesshttp://bloodpressure.oemig.de/fhir/ValueSet/Consciousness from this IG | |
BloodPressure.anaesthesia | required | Anaesthesiahttp://bloodpressure.oemig.de/fhir/ValueSet/Anaesthesia from this IG | |
BloodPressure.measurementSetting | extensible | MeasurementSettingVShttp://bloodpressure.oemig.de/fhir/ValueSet/MeasurementSetting from this IG |
Id | Grade | Path(s) | Details | Requirements |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
shall-be-under-1000-mmHg | error | BloodPressure.systolicPressure.value, BloodPressure.diastolicPressure.value, BloodPressure.meanArterialPressure.value, BloodPressure.pulsePressure.value | Value SHALL be <1000 mmHg for valid data. : $this < 1000 |
This structure is derived from Base
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
BloodPressure | 0..* | Base | Blood Pressure LM Instances of this logical model are not marked to be the target of a Reference | |
systolicPressure | Σ | 0..1 | BackboneElement | systolic blood pressure ele-1: All FHIR elements must have a @value or children |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Systolic Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range ele-1: All FHIR elements must have a @value or children | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
diastolicPressure | Σ | 0..1 | BackboneElement | diastolic blood pressure ele-1: All FHIR elements must have a @value or children |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Diastolic Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range ele-1: All FHIR elements must have a @value or children | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
meanArterialPressure | 0..1 | BackboneElement | mean arterial blood pressure ele-1: All FHIR elements must have a @value or children | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Mean Arterial Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range ele-1: All FHIR elements must have a @value or children | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
pulsePressure | 0..1 | BackboneElement | pulse blood pressure ele-1: All FHIR elements must have a @value or children | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Pulse Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range ele-1: All FHIR elements must have a @value or children | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
interpretation | Σ | 0..1 | CodeableConcept | overall clinical meaning of the BP measurement Binding: Interpretation (required) |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
range | 0..* | BackboneElement | reference range | |
effective[x] | Σ | 0..1 | date of observation | |
effectiveDate | date | |||
effectiveInstant | instant | |||
effectivePeriod | Period | |||
cuffType | 0..1 | CodeableConcept | type of cuff used (eg. rusable, disposable) Binding: Cuff Type (required) | |
cuffSize | 0..1 | CodeableConcept | size of cuff (eg. adult, child) Binding: Cuff Size (required) | |
position | 0..1 | CodeableConcept | position for measurement Binding: Position (required) | |
location | 0..1 | CodeableConcept | body location of measurement Binding: Location (required) | |
consciousness | 0..1 | CodeableConcept | Consciousness of the patient Binding: Consciousness (required) | |
exertion[x] | 0..1 | physical activity (measured in Watts or as coded information) | ||
exertionInteger | integer | |||
exertionCodeableConcept | CodeableConcept | |||
anaesthesia | 0..1 | CodeableConcept | Anaesthesia of patient during measurement Binding: Anaesthesia (required) | |
measurementSetting | 0..1 | CodeableConcept | The setting in which the measurement was performed; i.e. at home, at clinic, at emergency room, etc. Binding: Measurement Setting value set (extensible) | |
medication[x] | 0..1 | medication to be considered, minimum is the indication that there is some kind of medication | ||
medicationBoolean | boolean | |||
medicationReference | Reference(MedicationStatement) | |||
method | 0..1 | CodeableConcept | measurement method | |
tilt | 0..1 | integer | tilt (in degrees) | |
comment | 0..1 | string | any comment | |
subject | 0..1 | Reference(Patient) | reference to the subject of the measurement | |
author | 0..1 | Reference(Practitioner) | reference to the author of the measurement | |
performer | 0..1 | Reference(Practitioner) | reference to the performer of the measurement | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
BloodPressure.systolicPressure.code | extensible | USCoreSystolicBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code from this IG | |
BloodPressure.systolicPressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.systolicPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.systolicPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.diastolicPressure.code | extensible | USCoreDiastolicBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code from this IG | |
BloodPressure.diastolicPressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.diastolicPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.diastolicPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.meanArterialPressure.code | extensible | USCoreMeanArterialBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code from this IG | |
BloodPressure.meanArterialPressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.meanArterialPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.meanArterialPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.pulsePressure.code | extensible | USCorePulseBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code from this IG | |
BloodPressure.pulsePressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.pulsePressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.pulsePressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.cuffType | required | CuffType (a valid code from Cuff Type)http://bloodpressure.oemig.de/fhir/ValueSet/CuffType from this IG | |
BloodPressure.cuffSize | required | CuffSize (a valid code from Cuff Size)http://bloodpressure.oemig.de/fhir/ValueSet/CuffSize from this IG | |
BloodPressure.position | required | Positionhttp://bloodpressure.oemig.de/fhir/ValueSet/Position from this IG | |
BloodPressure.location | required | Locationhttp://bloodpressure.oemig.de/fhir/ValueSet/Location from this IG | |
BloodPressure.consciousness | required | Consciousnesshttp://bloodpressure.oemig.de/fhir/ValueSet/Consciousness from this IG | |
BloodPressure.anaesthesia | required | Anaesthesiahttp://bloodpressure.oemig.de/fhir/ValueSet/Anaesthesia from this IG | |
BloodPressure.measurementSetting | extensible | MeasurementSettingVShttp://bloodpressure.oemig.de/fhir/ValueSet/MeasurementSetting from this IG |
Id | Grade | Path(s) | Details | Requirements |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
shall-be-under-1000-mmHg | error | BloodPressure.systolicPressure.value, BloodPressure.diastolicPressure.value, BloodPressure.meanArterialPressure.value, BloodPressure.pulsePressure.value | Value SHALL be <1000 mmHg for valid data. : $this < 1000 |
Differential View
This structure is derived from Base
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
BloodPressure | 0..* | Base | Blood Pressure LM Instances of this logical model are not marked to be the target of a Reference | |
systolicPressure | Σ | 0..1 | BackboneElement | systolic blood pressure |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Systolic Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range | |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
diastolicPressure | Σ | 0..1 | BackboneElement | diastolic blood pressure |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Diastolic Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range | |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
meanArterialPressure | 0..1 | BackboneElement | mean arterial blood pressure | |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Mean Arterial Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range | |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
pulsePressure | 0..1 | BackboneElement | pulse blood pressure | |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Pulse Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range | |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
interpretation | Σ | 0..1 | CodeableConcept | overall clinical meaning of the BP measurement Binding: Interpretation (required) |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
range | 0..* | BackboneElement | reference range | |
effective[x] | Σ | 0..1 | date of observation | |
effectiveDate | date | |||
effectiveInstant | instant | |||
effectivePeriod | Period | |||
cuffType | 0..1 | CodeableConcept | type of cuff used (eg. rusable, disposable) Binding: Cuff Type (required) | |
cuffSize | 0..1 | CodeableConcept | size of cuff (eg. adult, child) Binding: Cuff Size (required) | |
position | 0..1 | CodeableConcept | position for measurement Binding: Position (required) | |
location | 0..1 | CodeableConcept | body location of measurement Binding: Location (required) | |
consciousness | 0..1 | CodeableConcept | Consciousness of the patient Binding: Consciousness (required) | |
exertion[x] | 0..1 | physical activity (measured in Watts or as coded information) | ||
exertionInteger | integer | |||
exertionCodeableConcept | CodeableConcept | |||
anaesthesia | 0..1 | CodeableConcept | Anaesthesia of patient during measurement Binding: Anaesthesia (required) | |
measurementSetting | 0..1 | CodeableConcept | The setting in which the measurement was performed; i.e. at home, at clinic, at emergency room, etc. Binding: Measurement Setting value set (extensible) | |
medication[x] | 0..1 | medication to be considered, minimum is the indication that there is some kind of medication | ||
medicationBoolean | boolean | |||
medicationReference | Reference(MedicationStatement) | |||
method | 0..1 | CodeableConcept | measurement method | |
tilt | 0..1 | integer | tilt (in degrees) | |
comment | 0..1 | string | any comment | |
subject | 0..1 | Reference(Patient) | reference to the subject of the measurement | |
author | 0..1 | Reference(Practitioner) | reference to the author of the measurement | |
performer | 0..1 | Reference(Practitioner) | reference to the performer of the measurement | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
BloodPressure.systolicPressure.code | extensible | USCoreSystolicBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code from this IG | |
BloodPressure.systolicPressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.systolicPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.systolicPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.diastolicPressure.code | extensible | USCoreDiastolicBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code from this IG | |
BloodPressure.diastolicPressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.diastolicPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.diastolicPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.meanArterialPressure.code | extensible | USCoreMeanArterialBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code from this IG | |
BloodPressure.meanArterialPressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.meanArterialPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.meanArterialPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.pulsePressure.code | extensible | USCorePulseBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code from this IG | |
BloodPressure.pulsePressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.pulsePressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.pulsePressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.cuffType | required | CuffType (a valid code from Cuff Type)http://bloodpressure.oemig.de/fhir/ValueSet/CuffType from this IG | |
BloodPressure.cuffSize | required | CuffSize (a valid code from Cuff Size)http://bloodpressure.oemig.de/fhir/ValueSet/CuffSize from this IG | |
BloodPressure.position | required | Positionhttp://bloodpressure.oemig.de/fhir/ValueSet/Position from this IG | |
BloodPressure.location | required | Locationhttp://bloodpressure.oemig.de/fhir/ValueSet/Location from this IG | |
BloodPressure.consciousness | required | Consciousnesshttp://bloodpressure.oemig.de/fhir/ValueSet/Consciousness from this IG | |
BloodPressure.anaesthesia | required | Anaesthesiahttp://bloodpressure.oemig.de/fhir/ValueSet/Anaesthesia from this IG | |
BloodPressure.measurementSetting | extensible | MeasurementSettingVShttp://bloodpressure.oemig.de/fhir/ValueSet/MeasurementSetting from this IG |
Id | Grade | Path(s) | Details | Requirements |
shall-be-under-1000-mmHg | error | BloodPressure.systolicPressure.value, BloodPressure.diastolicPressure.value, BloodPressure.meanArterialPressure.value, BloodPressure.pulsePressure.value | Value SHALL be <1000 mmHg for valid data. : $this < 1000 |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
BloodPressure | 0..* | Base | Blood Pressure LM Instances of this logical model are not marked to be the target of a Reference | |
systolicPressure | Σ | 0..1 | BackboneElement | systolic blood pressure |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Systolic Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
diastolicPressure | Σ | 0..1 | BackboneElement | diastolic blood pressure |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Diastolic Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
meanArterialPressure | 0..1 | BackboneElement | mean arterial blood pressure | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Mean Arterial Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
pulsePressure | 0..1 | BackboneElement | pulse blood pressure | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | 0..1 | CodeableConcept | code, in case of a precoordinated concept Binding: Vital Signs Pulse Blood Pressure Codes (extensible) | |
value | C | 1..1 | positiveInt | value shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. |
unit | 1..1 | CodeableConcept | units Binding: Blood Pressure Units (required) | |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
interpretation | 0..1 | CodeableConcept | interpretation Binding: Interpretation (required) | |
range | 0..* | BackboneElement | reference range | |
@id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
low | 0..1 | integer | Low Range, if relevant | |
high | 0..1 | integer | High Range, if relevant | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
interpretation | Σ | 0..1 | CodeableConcept | overall clinical meaning of the BP measurement Binding: Interpretation (required) |
dataAbsentReason | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (required) | |
range | 0..* | BackboneElement | reference range | |
effective[x] | Σ | 0..1 | date of observation | |
effectiveDate | date | |||
effectiveInstant | instant | |||
effectivePeriod | Period | |||
cuffType | 0..1 | CodeableConcept | type of cuff used (eg. rusable, disposable) Binding: Cuff Type (required) | |
cuffSize | 0..1 | CodeableConcept | size of cuff (eg. adult, child) Binding: Cuff Size (required) | |
position | 0..1 | CodeableConcept | position for measurement Binding: Position (required) | |
location | 0..1 | CodeableConcept | body location of measurement Binding: Location (required) | |
consciousness | 0..1 | CodeableConcept | Consciousness of the patient Binding: Consciousness (required) | |
exertion[x] | 0..1 | physical activity (measured in Watts or as coded information) | ||
exertionInteger | integer | |||
exertionCodeableConcept | CodeableConcept | |||
anaesthesia | 0..1 | CodeableConcept | Anaesthesia of patient during measurement Binding: Anaesthesia (required) | |
measurementSetting | 0..1 | CodeableConcept | The setting in which the measurement was performed; i.e. at home, at clinic, at emergency room, etc. Binding: Measurement Setting value set (extensible) | |
medication[x] | 0..1 | medication to be considered, minimum is the indication that there is some kind of medication | ||
medicationBoolean | boolean | |||
medicationReference | Reference(MedicationStatement) | |||
method | 0..1 | CodeableConcept | measurement method | |
tilt | 0..1 | integer | tilt (in degrees) | |
comment | 0..1 | string | any comment | |
subject | 0..1 | Reference(Patient) | reference to the subject of the measurement | |
author | 0..1 | Reference(Practitioner) | reference to the author of the measurement | |
performer | 0..1 | Reference(Practitioner) | reference to the performer of the measurement | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
BloodPressure.systolicPressure.code | extensible | USCoreSystolicBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code from this IG | |
BloodPressure.systolicPressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.systolicPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.systolicPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.diastolicPressure.code | extensible | USCoreDiastolicBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code from this IG | |
BloodPressure.diastolicPressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.diastolicPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.diastolicPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.meanArterialPressure.code | extensible | USCoreMeanArterialBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code from this IG | |
BloodPressure.meanArterialPressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.meanArterialPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.meanArterialPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.pulsePressure.code | extensible | USCorePulseBloodPressureCodeshttp://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code from this IG | |
BloodPressure.pulsePressure.unit | required | BPunitshttp://bloodpressure.oemig.de/fhir/ValueSet/BPunits from this IG | |
BloodPressure.pulsePressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.pulsePressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.interpretation | required | Interpretationhttp://bloodpressure.oemig.de/fhir/ValueSet/Interpretation from this IG | |
BloodPressure.dataAbsentReason | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
BloodPressure.cuffType | required | CuffType (a valid code from Cuff Type)http://bloodpressure.oemig.de/fhir/ValueSet/CuffType from this IG | |
BloodPressure.cuffSize | required | CuffSize (a valid code from Cuff Size)http://bloodpressure.oemig.de/fhir/ValueSet/CuffSize from this IG | |
BloodPressure.position | required | Positionhttp://bloodpressure.oemig.de/fhir/ValueSet/Position from this IG | |
BloodPressure.location | required | Locationhttp://bloodpressure.oemig.de/fhir/ValueSet/Location from this IG | |
BloodPressure.consciousness | required | Consciousnesshttp://bloodpressure.oemig.de/fhir/ValueSet/Consciousness from this IG | |
BloodPressure.anaesthesia | required | Anaesthesiahttp://bloodpressure.oemig.de/fhir/ValueSet/Anaesthesia from this IG | |
BloodPressure.measurementSetting | extensible | MeasurementSettingVShttp://bloodpressure.oemig.de/fhir/ValueSet/MeasurementSetting from this IG |
Id | Grade | Path(s) | Details | Requirements |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
shall-be-under-1000-mmHg | error | BloodPressure.systolicPressure.value, BloodPressure.diastolicPressure.value, BloodPressure.meanArterialPressure.value, BloodPressure.pulsePressure.value | Value SHALL be <1000 mmHg for valid data. : $this < 1000 |
This structure is derived from Base