Unable to compare with previous version: Unable to find version history at http://bloodpressure.oemig.de/fhir (Problem #1 with package-list.json at http://bloodpressure.oemig.de/fhir: bloodpressure.oemig.de)
IPA Comparison:
n/a
IPS Comparison:
n/a
Validation Flags:
On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings
This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/bp|4.0.1 (this may not be a problem, but you should check that it's not intended to match a slice)Show Reasoning
This element does not match any known slice Defined in the profile http://hl7.org/fhir/StructureDefinition/bp|4.0.1 (this may not be a problem, but you should check that it's not intended to match a slice)
Observation.category[0]: discriminator = true and ('vital-signs' in coding.code) and ('http://terminology.hl7.org/CodeSystem/observation-category' in coding.system)
Details_for__matching_against_Profile_
Observation.value.ofType(Quantity) (l19/c4)
error
This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/bp|4.0.1 and slicing is CLOSED: Observation.value.ofType(Quantity): Does not match slice 'valueQuantity' (discriminator: $this.empty())Validation_VAL_Profile_NotSlice
Observation (l1/c2)
error
Slice 'Observation.category:VSCat': a matching slice is required, but not found (from http://hl7.org/fhir/StructureDefinition/bp|4.0.1). Note that other slices are allowed in addition to this required sliceValidation_VAL_Profile_Minimum_SLICE
The definition for the element 'BloodPressure.systolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'BloodPressure.diastolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'BloodPressure.meanArterialPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'BloodPressure.pulsePressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'BloodPressure.systolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'BloodPressure.diastolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'BloodPressure.meanArterialPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'BloodPressure.pulsePressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'BloodPressureAverage.systolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'BloodPressureAverage.diastolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'BloodPressureAverage.systolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'BloodPressureAverage.diastolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The discriminator path 'system' does not appear to be valid for the element that is being sliced 'Observation.component'SD_PATH_NOT_VALID
StructureDefinition.snapshot (l1/c210947)
warning
The slice 'loinc' on path 'Observation.code.coding' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
StructureDefinition.snapshot (l1/c210947)
warning
The slice 'snomed' on path 'Observation.code.coding' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
StructureDefinition.snapshot (l1/c210947)
warning
The slice 'SystolicBP' on path 'Observation.component' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
StructureDefinition.snapshot (l1/c210947)
warning
The slice 'DiastolicBP' on path 'Observation.component' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
StructureDefinition.snapshot (l1/c210947)
warning
The slice 'meanBP' on path 'Observation.component' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
The definition for the element 'OBXsegment.observationCode' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'OBXsegment.observationCode' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
A definition for CodeSystem 'http://bloodpressure.oemig.de/fhir/CodeSystem/v2DataType' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4) UNKNOWN_CODESYSTEM
A definition for CodeSystem 'http://bloodpressure.oemig.de/fhir/CodeSystem/v2DataType' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4) UNKNOWN_CODESYSTEM
A definition for CodeSystem 'http://bloodpressure.oemig.de/fhir/CodeSystem/v2DataType' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4) UNKNOWN_CODESYSTEM
A definition for CodeSystem 'http://bloodpressure.oemig.de/fhir/CodeSystem/v2DataType' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4) UNKNOWN_CODESYSTEM
The definition for the element 'OBXsegment.observationCode' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'OBXsegment.observationCode' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier' to 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier' to 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
PIDsegment.patid (l1/c13307)
information
The extension http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.2.0 is deprecatedMSG_DEPENDS_ON_DEPRECATED
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier' to 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier' to 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition' to 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition' to 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition|5.2.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-body-position.json - the canonical URL (http://bloodpressure.oemig.de/fhir/ValueSet/body-position) does not match the URL (http://bloodpressure.oemig.de/fhir/ValueSet/body_position)RESOURCE_CANONICAL_MISMATCH
The system 'http://bloodpressure.oemig.de/fhir/ValueSet/body_position_core' is actually a value set, which itself refers to the system 'http://snomed.sct' so that may be what is intended hereVALUESET_INCLUDE_WRONG_VS_HINT
ValueSet.compose.include[1] (l1/c1147)
error
The system 'http://bloodpressure.oemig.de/fhir/ValueSet/body_position_extended' is actually a value set, which itself refers to the system 'http://snomed.sct' so that may be what is intended hereVALUESET_INCLUDE_WRONG_VS_HINT
ValueSet.where(id = 'body-position')
error
Error from https://tx.fhir.org/r4: Attempt to reference http://bloodpressure.oemig.de/fhir/ValueSet/body_position_core as a CodeSystem when it's a ValueSet (from server, see log)
fsh-generated/resources/ValueSet-body-position
error
URL Mismatch http://bloodpressure.oemig.de/fhir/ValueSet/body-position vs http://bloodpressure.oemig.de/fhir/ValueSet/body_position
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-body-position-core.json - the canonical URL (http://bloodpressure.oemig.de/fhir/ValueSet/body-position-core) does not match the URL (http://bloodpressure.oemig.de/fhir/ValueSet/body_position_core)RESOURCE_CANONICAL_MISMATCH
A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validatedA definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated
The code '40199007' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)VALUESET_INCLUDE_INVALID_CONCEPT_CODE
ValueSet.where(id = 'body-position-core')
warning
Error from https://tx.fhir.org/r4: Unable to provide support for code system http://snomed.sct (from server, see log)
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-body-position-xtended.json - the canonical URL (http://bloodpressure.oemig.de/fhir/ValueSet/body-position-xtended) does not match the URL (http://bloodpressure.oemig.de/fhir/ValueSet/body_position_extended)RESOURCE_CANONICAL_MISMATCH
A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validatedA definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated
The code '26527006' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code '102536004' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code '414585002' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code '10904000' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code '1240000' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code '102538003' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code '423413008' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code '102535000' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code '415346000' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code '34106002' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)VALUESET_INCLUDE_INVALID_CONCEPT_CODE
ValueSet.where(id = 'body-position-xtended')
warning
Error from https://tx.fhir.org/r4: Unable to provide support for code system http://snomed.sct (from server, see log)
The code 'moreDiastolicCodesToAdd' is not valid in the system http://loinc.org (Unknown code 'moreDiastolicCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.81')VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code 'moreMeanArterialCodesToAdd' is not valid in the system http://loinc.org (Unknown code 'moreMeanArterialCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.81')VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code 'moreCodesToAdd' is not valid in the system http://loinc.org (Unknown code 'moreCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.81')VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code 'morePulseCodesToAdd' is not valid in the system http://loinc.org (Unknown code 'morePulseCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.81')VALUESET_INCLUDE_INVALID_CONCEPT_CODE
Unknown code 'morePulseCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.81'Unknown code 'morePulseCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.81'
The code 'moreSystolicCodesToAdd' is not valid in the system http://loinc.org (Unknown code 'moreSystolicCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.81')VALUESET_INCLUDE_INVALID_CONCEPT_CODE
This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/bp|4.0.1 (this may not be a problem, but you should check that it's not intended to match a slice)
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-body-position.json - the canonical URL (http://bloodpressure.oemig.de/fhir/ValueSet/body-position) does not match the URL (http://bloodpressure.oemig.de/fhir/ValueSet/body_position)
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-body-position-core.json - the canonical URL (http://bloodpressure.oemig.de/fhir/ValueSet/body-position-core) does not match the URL (http://bloodpressure.oemig.de/fhir/ValueSet/body_position_core)
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-body-position-xtended.json - the canonical URL (http://bloodpressure.oemig.de/fhir/ValueSet/body-position-xtended) does not match the URL (http://bloodpressure.oemig.de/fhir/ValueSet/body_position_extended)
The definition for the element 'BloodPressure.systolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressure.diastolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressure.meanArterialPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressure.pulsePressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressure.systolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressure.diastolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressure.meanArterialPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressure.pulsePressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressureAverage.systolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressureAverage.diastolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressureAverage.systolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressureAverage.diastolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'OBXsegment.observationCode' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'OBXsegment.observationCode' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'OBXsegment.observationCode' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'OBXsegment.observationCode' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier' to 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier' to 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier' to 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier' to 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition' to 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition|5.2.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition' to 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition|5.2.0'
The code '40199007' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)
The code '26527006' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)
The code '102536004' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)
The code '414585002' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)
The code '10904000' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)
The code '1240000' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)
The code '102538003' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)
The code '423413008' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)
The code '102535000' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)
The code '415346000' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)
The code '34106002' is not valid in the system http://snomed.sct (A definition for CodeSystem 'http://snomed.sct' could not be found, so the code cannot be validated)
The code 'moreDiastolicCodesToAdd' is not valid in the system http://loinc.org (Unknown code 'moreDiastolicCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.81')
The code 'moreMeanArterialCodesToAdd' is not valid in the system http://loinc.org (Unknown code 'moreMeanArterialCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.81')
The code 'moreCodesToAdd' is not valid in the system http://loinc.org (Unknown code 'moreCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.81')
The code 'morePulseCodesToAdd' is not valid in the system http://loinc.org (Unknown code 'morePulseCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.81')
The code 'moreSystolicCodesToAdd' is not valid in the system http://loinc.org (Unknown code 'moreSystolicCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.81')
The system 'http://bloodpressure.oemig.de/fhir/ValueSet/body_position_core' is actually a value set, which itself refers to the system 'http://snomed.sct' so that may be what is intended here
The system 'http://bloodpressure.oemig.de/fhir/ValueSet/body_position_extended' is actually a value set, which itself refers to the system 'http://snomed.sct' so that may be what is intended here
Slice 'Observation.category:VSCat': a matching slice is required, but not found (from http://hl7.org/fhir/StructureDefinition/bp|4.0.1). Note that other slices are allowed in addition to this required slice
This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/bp|4.0.1 and slicing is CLOSED: Observation.value.ofType(Quantity): Does not match slice 'valueQuantity' (discriminator: $this.empty())