 0 Table of Contents |
  1 Home |
  2 Overview |
  3 Abbreviations and Definitions |
  4 Technical Implementation Guidance |
   4.1 HL7 V2 Mapping |
   4.2 Mapping from IEEE 11073-10201 DIM to FHIR |
   4.3 Mapping from IEEE 11073-10207 SDC to FHIR |
   4.4 RESTful Transfer |
   4.5 FHIR Messaging |
  5 Profiles |
  6 Terminology |
  7 Artifact List |
   7.1 Server CapabilityStatement |
   7.2 Patient profile |
   7.3 Practitioner profile |
   7.4 Observation profile |
   7.5 MDS Device profile |
   7.6 VMD Device profile |
   7.7 Channel Device profile |
   7.8 Numeric DeviceMetric profile |
   7.9 Enumeration DeviceMetric profile |
   7.10 Sample Array DeviceMetric profile |
   7.11 Numeric Observation profile |
   7.12 Compound Numeric Observation profile |
   7.13 Enumeration Observation profile |
   7.14 Sample Array Observation profile |
   7.15 Device Instance extension |
   7.16 Approved Jurisdictions extension |
   7.17 Operator extension |
   7.18 Operating hours extension |
   7.19 Operating cycles extension |
   7.20 Operating mode extension |
   7.21 Relation extension |
   7.22 Metric availability extension |
   7.23 Technical range extension |
   7.24 Resolution extension |
   7.25 Sweep Speed extension |
   7.26 Visual Grid extension |
   7.27 Reference range extension |
   7.28 Reference range type value set |
   7.29 MDC Object infrastructure and Device nomenclature |
   7.30 MDC Metric nomenclature |
   7.31 MDC Unit of Measurement |
   7.32 Operating mode value set |
   7.33 Safety classification value set |
   7.34 Kind of relation value set |
   7.35 Metric availability value set |
   7.36 Observation interpretation codes |
   7.37 Safety |
   7.38 Operating mode code system |
   7.39 Safety classification code system |
   7.40 Kind of relation code system |
   7.41 Metric availability code system |
   7.42 Measurement status codes |
   7.43 Reference range type code system |
   7.44 Patient Monitor MDS example |
   7.45 ECG VMD example |
   7.46 ECG Channel example |
   7.47 ECG Sample Array metric example |
   7.48 ECG Sample Array observation example |
   7.49 Rhythm Status Enumeration metric example |
   7.50 Rhythm Status Enumeration observation example |
   7.51 Heart Rate Channel example |
   7.52 Heart Rate Numeric metric example |
   7.53 Heart Rate Numeric observation example |
   7.54 Blood Pressure VMD example |
   7.55 Blood Pressure Channel example |
   7.56 CVP Sample Array metric example |
   7.57 CVP Sample Array observation example |
   7.58 NBP VMD example |
   7.59 NBP Channel example |
   7.60 NBP Numeric metric example |
   7.61 NBP Numeric observation example |
   7.62 Some Patient example |
   7.63 Some Practitioner example |
   7.64 Some Location example |
  8 Downloads |
  9 Appendix |
  10 Change Log |