STU 1. This version has been balloted and is being published for use in testing and implementation. It is not yet ready for production use.
changes
input/pagecontent/changes.xml
RelatedIgs
(None Found)
The file package-list.json should not exist in the root folder
Proposed path for this publication should usually be the canonical with the version or sequence appended and then some kind of label (typically '-snapshot')
This release is not labelled as a milestone or technical correction, so should have a patch version (1.0.0)
The jira specification file appears to be out of date with the versions, artifacts and pages currently defined in the IG. A proposed revised file to be reviewed and, if appropriate, submitted as a pull request against the XML folder in https://github.com/HL7/JIRA-Spec-Artifacts. To see the differences, perform a file compare on 'template/jira-current.xml' (a normalized view of what is in Github) and 'template/jira-new.xml' (reflects current IG content)
Wrong Display Name 'United States of America (the)' for urn:iso:std:iso:3166#US. Valid display is 'United States of America' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4) Display_Name_for__should_be_one_of__instead_of
Error from https://tx.fhir.org/r4: Error: A definition for CodeSystem 'http://hl7.org/fhir/uv/pocd/CodeSystem/safety' could not be found, so the value set cannot be expanded (from server, see log)
Example observation in this IG are supposed to be device generated with often an unknown performer. There will be text in the IG to explain this.
Best Practice Recommendation: In general, all observations should have a performer (5 uses)
Moving code systems and URLs to THO will be discussed in the near future. For now, these warnings can be ignored safely.
Most code systems defined in HL7 IGs will need to move to THO later during the process. Consider giving this code system a THO URL now (See https://confluence.hl7.org/display/TSMG/Terminology+Play+Book, and/or talk to TSMG) (3 uses)
Publisher process choice - can safely be ignored
The value set expansion is too large, and only a subset has been displayed (3 uses)
Reference to external draft code system that is not really draft. This message can be ignored safely.
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 (0 uses)
The following profiles are only used to define mappings
WARNING: StructureDefinition.where(url = 'http://hl7.org/fhir/uv/pocd/StructureDefinition/Observation'): The Implementation Guide contains no examples for this profile (0 uses)
These profiles are only used to define mappings and are not intended to be used for validation. These warnings can be ignored safely.
Observation is labeled as an abstract type, but no concrete descendants were found (check definitions - this is usually an error unless concrete definitions are in some other package) (1 uses)
Patient is labeled as an abstract type, but no concrete descendants were found (check definitions - this is usually an error unless concrete definitions are in some other package) (1 uses)
Practitioner is labeled as an abstract type, but no concrete descendants were found (check definitions - this is usually an error unless concrete definitions are in some other package) (1 uses)
These warnings are caused by checking a slice with an MDC code against a the BP profile in FHIR core. These messages are expected and can be ignored safely.
This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/bp|4.0.1 (this may not be a problem, but you should check that it's not intended to match a slice) (3 uses)
This code system is referenced by a FHIR core value set and is really not a draft. This warning can safely be ignored. And instead of defining a local extension in the IG the FHIR jurisdiction extension could be used as well in
Reference to draft CodeSystem urn:iso:std:iso:3166|20210120 (0 uses)
code system is part of the IG which has draft status. This warning can be ignored safely.
Reference to draft CodeSystem http://hl7.org/fhir/uv/pocd/CodeSystem/reference-range-type|0.4.0 (0 uses)
extension used in FHIR core R4 that is now deprecated - this warning can be ignored safely
The extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.2.0 is deprecated (1 uses)
Wrong Display Name 'United States of America (the)' for urn:iso:std:iso:3166#US. Valid display is 'United States of America' (en) (for the language(s) 'en-US')