International Patient Summary Implementation Guide, published by HL7 International / Patient Care. This guide is not an authorized publication; it is the continuous build for version 2.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/fhir-ips/ and changes regularly. See the Directory of published versions
Official URL: http://hl7.org/fhir/uv/ips/StructureDefinition/Quantity-uv-ips | Version: 2.0.0 | |||
Standards status: Trial-use | Maturity Level: 2 | Computable Name: QuantityIPS |
Data type Quantity constrained to use UCUM as the code system for units
This profile of the Quantity data type imposes the usage of the UCUM as the code system for units
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Quantity | C | 0..* | Quantity | A measured amount using UCUM qty-3: If a code for the unit is present, the system SHALL also be present |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
system | SΣC | 1..1 | uri | UCUM system for units Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | Coded form of the unit |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Quantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
qty-3 | error | Quantity | If a code for the unit is present, the system SHALL also be present : code.empty() or system.exists() |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Quantity | C | 0..* | Quantity | A measured amount using UCUM qty-3: If a code for the unit is present, the system SHALL also be present |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
value | Σ | 0..1 | decimal | Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
unit | Σ | 0..1 | string | Unit representation |
system | SΣC | 1..1 | uri | UCUM system for units Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | Coded form of the unit |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Quantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
qty-3 | error | Quantity | If a code for the unit is present, the system SHALL also be present : code.empty() or system.exists() |
Differential View
This structure is derived from Quantity
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Quantity | C | 0..* | Quantity | A measured amount using UCUM qty-3: If a code for the unit is present, the system SHALL also be present |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
system | SΣC | 1..1 | uri | UCUM system for units Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | Coded form of the unit |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Quantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
qty-3 | error | Quantity | If a code for the unit is present, the system SHALL also be present : code.empty() or system.exists() |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Quantity | C | 0..* | Quantity | A measured amount using UCUM qty-3: If a code for the unit is present, the system SHALL also be present |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
value | Σ | 0..1 | decimal | Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
unit | Σ | 0..1 | string | Unit representation |
system | SΣC | 1..1 | uri | UCUM system for units Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | Coded form of the unit |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Quantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
qty-3 | error | Quantity | If a code for the unit is present, the system SHALL also be present : code.empty() or system.exists() |
Other representations of profile: CSV, Excel, Schematron