Consolidated CDA (C-CDA)
4.0.0-ballot - STU4 United States of America flag

Consolidated CDA (C-CDA), published by Health Level Seven. This guide is not an authorized publication; it is the continuous build for version 4.0.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/CDA-ccda/ and changes regularly. See the Directory of published versions

Example Binary: Result Observation Example

This content is an example of the Result Observation Logical Model and is not a FHIR Resource

    
<observation classCode="OBS" moodCode="EVN" xmlns="urn:hl7-org:v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
  <templateId root="2.16.840.1.113883.10.20.22.4.2" extension="2023-05-01" />
  <id root="7c0704bb-9c40-41b5-9c7d-26b2d59e234f" />
  <code code="20570-8" displayName="Hematocrit [Volume Fraction] of Blood" codeSystem="2.16.840.1.113883.6.1"
codeSystemName="LOINC" />
  <statusCode code="completed" />
  <effectiveTime value="200803190830-0800" />
  <value xsi:type="PQ" value="35.3" unit="%" />
  <interpretationCode code="L" codeSystem="2.16.840.1.113883.5.83" />
  <author>
    <templateId root="2.16.840.1.113883.10.20.22.4.119" />
    <time value="200803190830-0800" />
    <assignedAuthor>
      <id extension="333444444" root="1.1.1.1.1.1.1.4" />
      <addr use="HP">
        <streetAddressLine>1017 Health Drive</streetAddressLine>
        <city>Portland</city>
        <state>OR</state>
        <postalCode>99123</postalCode>
        <country>US</country>
      </addr>
      <telecom use="WP" value="tel:+1(555)555-1017" />
      <assignedPerson>
        <name>
          <given>William</given>
          <given qualifier="CL">Bill</given>
          <family>Beaker</family>
        </name>
      </assignedPerson>
      <representedOrganization>
        <name>Good Health Laboratory</name>
      </representedOrganization>
    </assignedAuthor>
  </author>
  <referenceRange>
    <observationRange>
      <text>Low</text>
      <value xsi:type="IVL_PQ">
        <low value="34.9" unit="%" />
        <high value="44.5" unit="%" />
      </value>
      <interpretationCode code="L" codeSystem="2.16.840.1.113883.5.83"/>
    </observationRange>
  </referenceRange>
</observation>