This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times). 
See the Directory of published versions 
http://hl7.org/fhir/SearchParameter/Specimen-bodysite | 
  10.8.15 bodysite Parameter bodysite:reference 
Reference to a resource (by instance) 
 
| Resource | Specimen |  
| Expression | 
Specimen.collection.bodySite.reference |  
| Processing Mode | 
Normal |  
| Target Resources | 
BodyStructure |  
| Multiples | 
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
 - multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
  |  
   | 
|   | 
http://hl7.org/fhir/SearchParameter/Specimen-collected | 
  10.8.16 collected Parameter collected:date 
The date the specimen was collected 
 
| Resource | Specimen |  
| Expression | 
Specimen.collection.collected.ofType(dateTime) | Specimen.collection.collected.ofType(Period) |  
| Processing Mode | 
Normal |  
| Multiples | 
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
 - multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
  |  
| Comparators | 
Allowed: eq, ne, gt, ge, lt, le, sa, eb, ap |  
   | 
|   | 
http://hl7.org/fhir/SearchParameter/Specimen-collection-device-code | 
  10.8.17 collection-device-code Parameter collection-device-code:token 
The code associated with the collection device 
 
| Resource | Specimen |  
| Expression | 
Specimen.collection.device.ofType(CodeableConcept) |  
| Processing Mode | 
Normal |  
| Multiples | 
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
 - multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
  |  
   | 
|   | 
http://hl7.org/fhir/SearchParameter/Specimen-collector | 
  10.8.18 collector Parameter collector:reference 
Who collected the specimen 
 
| Resource | Specimen |  
| Expression | 
Specimen.collection.collector |  
| Processing Mode | 
Normal |  
| Target Resources | 
Organization, RelatedPerson, PractitionerRole, Practitioner, Patient |  
| Multiples | 
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
 - multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
  |  
   | 
|   | 
http://hl7.org/fhir/SearchParameter/Specimen-container-device-code | 
  10.8.19 container-device-code Parameter container-device-code:token 
The code associated with the specimen container 
 
| Resource | Specimen |  
| Expression | 
Specimen.container.device.ofType(CodeableConcept) |  
| Processing Mode | 
Normal |  
| Multiples | 
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
 - multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
  |  
   | 
|   | 
http://hl7.org/fhir/SearchParameter/clinical-identifier | 
| This search parameter is part of the common search parameter clinical-identifier | 
  10.8.20 identifier Parameter identifier:token 
Specimen: The unique identifier associated with the specimen 
 
| Resource | Specimen |  
| Expression | 
Specimen.identifier |  
| Processing Mode | 
Normal |  
| Multiples | 
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
 - multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
  |  
   | 
|   | 
http://hl7.org/fhir/SearchParameter/Specimen-parent | 
  10.8.21 parent Parameter parent:reference 
The parent of the specimen 
 
| Resource | Specimen |  
| Expression | 
Specimen.parent |  
| Processing Mode | 
Normal |  
| Target Resources | 
Specimen |  
| Multiples | 
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
 - multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
  |  
   | 
|   | 
http://hl7.org/fhir/SearchParameter/clinical-patient | 
| This search parameter is part of the common search parameter clinical-patient | 
  10.8.22 patient Parameter patient:reference 
Specimen: The patient the specimen comes from 
 
| Resource | Specimen |  
| Expression | 
Specimen.subject.where(resolve() is Patient) |  
| Processing Mode | 
Normal |  
| Target Resources | 
Patient |  
| Multiples | 
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
 - multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
  |  
   | 
|   | 
http://hl7.org/fhir/SearchParameter/Specimen-procedure | 
  10.8.23 procedure Parameter procedure:reference 
The procedure that collected the specimen 
 
| Resource | Specimen |  
| Expression | 
Specimen.collection.procedure |  
| Processing Mode | 
Normal |  
| Target Resources | 
Procedure |  
| Multiples | 
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
 - multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
  |  
   | 
|   | 
http://hl7.org/fhir/SearchParameter/Specimen-processing-device-code | 
  10.8.24 processing-device-code Parameter processing-device-code:token 
The code associated with the processing device 
 
| Resource | Specimen |  
| Expression | 
Specimen.processing.device.ofType(CodeableConcept) |  
| Processing Mode | 
Normal |  
| Multiples | 
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
 - multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
  |  
   | 
|   | 
http://hl7.org/fhir/SearchParameter/Specimen-request | 
  10.8.25 request Parameter request:reference 
The request/order associated with the specimen 
 
| Resource | Specimen |  
| Expression | 
Specimen.request |  
| Processing Mode | 
Normal |  
| Target Resources | 
ServiceRequest |  
| Multiples | 
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
 - multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
  |  
   | 
|   | 
http://hl7.org/fhir/SearchParameter/Specimen-status | 
  10.8.26 status Parameter status:token 
available | unavailable | unsatisfactory | entered-in-error 
 
| Resource | Specimen |  
| Expression | 
Specimen.status |  
| Processing Mode | 
Normal |  
| Multiples | 
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
 - multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
  |  
   | 
|   | 
http://hl7.org/fhir/SearchParameter/Specimen-subject | 
  10.8.27 subject Parameter subject:reference 
The subject of the specimen 
 
| Resource | Specimen |  
| Expression | 
Specimen.subject |  
| Processing Mode | 
Normal |  
| Target Resources | 
Device, NutritionProduct, Group, BiologicallyDerivedProduct, Substance, Location, Patient |  
| Multiples | 
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
 - multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
  |  
   | 
|   | 
http://hl7.org/fhir/SearchParameter/clinical-type | 
| This search parameter is part of the common search parameter clinical-type | 
  10.8.28 type Parameter type:token 
| Resource | Specimen |  
| Expression | 
Specimen.type |  
| Processing Mode | 
Normal |  
| Multiples | 
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
 - multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
  |  
   | 
|   |