QI-Core Implementation Guide, published by HL7 International / Clinical Quality Information. This guide is not an authorized publication; it is the continuous build for version 7.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/fhir-qi-core/ and changes regularly. See the Directory of published versions

Resource Profile: QICore DeviceUseStatement

Official URL: http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-deviceusestatement Version: 7.0.0
Active as of 2018-08-22 Computable Name: QICoreDeviceUseStatement

Profile of DeviceUseStatement for decision support/quality metrics. Defines the core set of elements and extensions for quality rule and measure authors.

"Must Have", "QI Elements" and "primary code path" are defined in the QI-Core Must Support section.
QI Elements:
  • status: (QI) active | completed | entered-in-error +
  • subject: (QI) Patient using device
  • timing[x]: (QI) How often the device was used
  • recordedOn: (QI) When statement was recorded
  • device: (QI) Reference to device used
  • bodySite: (QI) Target body site
Primary code path: device.type
(PCPath) This element is the primary code path for this resource CQL Retrieve


NOTE TO BALLOT REVIEWERS:
  • US Core 7.0, and thus QI-Core 7.0, has a new approach to USCDI requirements.
    • As noted in the US Core 7.0 Must Support section, US Core 7.0 no longer highlights mandatory (cardinality 1..* or 1..1) and Must Support elements with a (USCDI) indicator as such items must be supported for interoperability.
    • Those USCDI elements that are not mandatory or Must Support now include an indicator (ADDITIONAL USCDI) in US Core. QI-Core 7.0 does not reference USCDI elements; rather, users should access US Core 7.0 to understand its implementation of USCDI version 4.
  • We invite comments about the approach and suggestions for other options that would also avoid unnecessary noise or reading load to the QI-Core profile representation.
  • Further, QI-Core 7.0 does not discuss USCDI+Quality because at the time of ballot preparation, no published version of USCDI+Quality is available. We seek reviewer advice regarding how QI-Core might address future USCDI+Quality.

Usage

See the patterns page for implementation and usage patterns.

Examples

The provision of a wheelchair to a patient example

Usage:

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

NameFlagsCard.TypeDescription & Constraintsdoco
.. DeviceUseStatement 0..* DeviceUseStatement Record of use of a device
dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label
dom-6: A resource should have narrative for robust management
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
ele-1: All FHIR elements must have a @value or children
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
... status ?!Σ 1..1 code (QI) active | completed | entered-in-error +
Binding: DeviceUseStatementStatus (required): A coded concept indicating the current status of the Device Usage.


ele-1: All FHIR elements must have a @value or children
... timing[x] Σ 0..1 (QI) How often the device was used
ele-1: All FHIR elements must have a @value or children
.... timingTiming Timing
.... timingPeriod Period
.... timingDateTime dateTime
... recordedOn Σ 0..1 dateTime (QI) When statement was recorded
ele-1: All FHIR elements must have a @value or children
... device Σ 1..1 Reference(QICore Device | US Core Implantable Device Profile) (QI) Reference to device used
ele-1: All FHIR elements must have a @value or children
... bodySite Σ 0..1 CodeableConcept (QI) Target body site
Binding: SNOMEDCTBodyStructures (preferred): Codes describing anatomical locations. May include laterality.


ele-1: All FHIR elements must have a @value or children

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
DeviceUseStatement.statusrequiredDeviceUseStatementStatus
http://hl7.org/fhir/ValueSet/device-statement-status|4.0.1
from the FHIR Standard
DeviceUseStatement.bodySitepreferredSNOMEDCTBodyStructures
http://hl7.org/fhir/ValueSet/body-site
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorDeviceUseStatementIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorDeviceUseStatementIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorDeviceUseStatementIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorDeviceUseStatementIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceDeviceUseStatementA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()

 

Other representations of profile: CSV, Excel, Schematron