ValueSet Example using code filter (intensional) (id = "example-intensional")
<?xml version="1.0" encoding="UTF-8"?>
<ValueSet xmlns="http://hl7.org/fhir">
<id value="example-intensional"/>
<meta>
<profile value="http://hl7.org/fhir/StructureDefinition/shareablevalueset"/>
</meta>
<text>
<status value="additional"/>
<div xmlns="http://www.w3.org/1999/xhtml">
<p> Value set "LOINC Codes for Cholesterol": This is an example value set
that includes
all the codes for serum cholesterol from LOINC v2.36.</p>
<p> Developed by: FHIR project team (example)</p>
<p> Published for testing on 13-June 2012</p>
<p> This value set includes all the LOINC codes in LOINC Part Concept Cholesterol |
Bld-Ser-Plas (LP382412-7), except for 5932-9 Cholesterol [Presence] in Blood by
Test strip</p>
<p> This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the
LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use</p>
</div>
</text>
<extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
<valueCode value="vocab"/>
</extension>
<url value="http://hl7.org/fhir/ValueSet/example-intensional"/>
<identifier>
<system value="urn:ietf:rfc:3986"/>
<value value="urn:oid:2.16.840.1.113883.4.642.3.3145"/>
</identifier>
<identifier>
<system value="http://acme.com/identifiers/valuesets"/>
<value value="loinc-cholesterol-ext"/>
</identifier>
<version value="6.0.0-ballot2"/>
<name value="LOINCCodesForCholesterolInSerumPlasma"/>
<title value="LOINC Codes for Cholesterol in Serum/Plasma"/>
<status value="draft"/>
<experimental value="true"/>
<date value="2015-06-22"/>
<publisher value="HL7 International / Terminology Infrastructure"/>
<contact>
<telecom>
<system value="url"/>
<value value="http://www.hl7.org/Special/committees/Vocab"/>
</telecom>
</contact>
<description value="This is an example value set that includes all the LOINC codes for serum/plasma
cholesterol from v2.36."/>
<copyright value="This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and
the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-
use"/>
<compose>
<include>
<system value="http://loinc.org"/>
<filter>
<property value="parent"/>
<op value="="/>
<value value="LP382412-7"/>
</filter>
</include>
<exclude>
<system value="http://loinc.org"/>
<concept>
<code value="5932-9"/>
<display value="Cholesterol [Presence] in Blood by Test strip"/>
</concept>
</exclude>
</compose>
</ValueSet>