This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions
ValueSet Example using code filter (intensional)
{
"resourceType" : "ValueSet",
"id" : "example-intensional",
"meta" : {
"profile" : ["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]
},
"text" : {
"status" : "additional",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n \n <p>Value set "LOINC Codes for Cholesterol": This is an example value set that includes \n all the codes for serum cholesterol from LOINC v2.36.</p>\n \n <p>Developed by: FHIR project team (example)</p>\n \n <p>Published for testing on 13-June 2012</p>\n \n <p>This value set includes all the LOINC codes in LOINC Part Concept Cholesterol | Bld-Ser-Plas (LP382412-7), except for 5932-9 Cholesterol [Presence] in Blood by Test strip</p>\n \n <p>This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use</p>\n \n </div>"
},
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode" : "vocab"
}],
"url" : "http://hl7.org/fhir/ValueSet/example-intensional",
"identifier" : [{
"system" : "urn:ietf:rfc:3986",
"value" : "urn:oid:2.16.840.1.113883.4.642.3.3145"
},
{
"system" : "http://acme.com/identifiers/valuesets",
"value" : "loinc-cholesterol-ext"
}],
"version" : "6.0.0-ballot2",
"name" : "LOINCCodesForCholesterolInSerumPlasma",
"title" : "LOINC Codes for Cholesterol in Serum/Plasma",
"status" : "draft",
"experimental" : true,
"date" : "2015-06-22",
"publisher" : "HL7 International / Terminology Infrastructure",
"contact" : [{
"telecom" : [{
"system" : "url",
"value" : "http://www.hl7.org/Special/committees/Vocab"
}]
}],
"description" : "This is an example value set that includes all the LOINC codes for serum/plasma cholesterol from v2.36.",
"copyright" : "This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use",
"compose" : {
"include" : [{
"system" : "http://loinc.org",
"filter" : [{
"property" : "parent",
"op" : "=",
"value" : "LP382412-7"
}]
}],
"exclude" : [{
"system" : "http://loinc.org",
"concept" : [{
"code" : "5932-9",
"display" : "Cholesterol [Presence] in Blood by Test strip"
}]
}]
}
}
Usage note: every effort has been made to ensure that the
examples are correct and useful, but they are not a normative part
of the specification.