This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times). See the Directory of published versions
Search parameters for the Resource ImagingSelection - Search Parameters resource. Also check the Extensions registry for search parameters
on extensions related to this resource.
http://hl7.org/fhir/SearchParameter/ImagingSelection-based-on
10.6.14 based-on Parameter based-on
:reference
The request associated with an imaging selection
Resource ImagingSelection
Expression
ImagingSelection.basedOn
Processing Mode
Normal
Target Resources
Appointment , ServiceRequest , CarePlan , Task , AppointmentResponse
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/ImagingSelection-body-site
10.6.15 body-site Parameter body-site
:token
The body site code associated with the imaging selection
Resource ImagingSelection
Expression
ImagingSelection.bodySite.concept
Processing Mode
Normal
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/ImagingSelection-body-structure
10.6.16 body-structure Parameter body-structure
:reference
The body structure associated with the imaging selection
Resource ImagingSelection
Expression
ImagingSelection.bodySite.reference
Processing Mode
Normal
Target Resources
BodyStructure
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/ImagingSelection-category
10.6.17 category Parameter category
:token
The imaging selection category
Resource ImagingSelection
Expression
ImagingSelection.category
Processing Mode
Normal
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/clinical-code
This search parameter is part of the common search parameter clinical-code
10.6.18 code Parameter code
:token
Resource ImagingSelection
Expression
ImagingSelection.code
Processing Mode
Normal
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/ImagingSelection-derived-from
10.6.19 derived-from Parameter derived-from
:reference
The imaging study from which the imaging selection was derived
Resource ImagingSelection
Expression
ImagingSelection.derivedFrom
Processing Mode
Normal
Target Resources
ImagingStudy , DocumentReference
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/clinical-identifier
This search parameter is part of the common search parameter clinical-identifier
10.6.20 identifier Parameter identifier
:token
Resource ImagingSelection
Expression
ImagingSelection.identifier
Processing Mode
Normal
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/ImagingSelection-issued
10.6.21 issued Parameter issued
:date
The date / time the imaging selection was created
Resource ImagingSelection
Expression
ImagingSelection.issued
Processing Mode
Normal
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
Comparators
Allowed: eq, ne, gt, ge, lt, le, sa, eb, ap
http://hl7.org/fhir/SearchParameter/clinical-patient
This search parameter is part of the common search parameter clinical-patient
10.6.22 patient Parameter patient
:reference
Resource ImagingSelection
Expression
ImagingSelection.subject.where(resolve() is Patient)
Processing Mode
Normal
Target Resources
Patient
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/ImagingSelection-status
10.6.23 status Parameter status
:token
The status of the imaging selection
Resource ImagingSelection
Expression
ImagingSelection.status
Processing Mode
Normal
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/ImagingSelection-study-uid
10.6.24 study-uid Parameter study-uid
:token
The DICOM Study Instance UID from which the images were selected
Resource ImagingSelection
Expression
ImagingSelection.studyUid
Processing Mode
Normal
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/ImagingSelection-subject
10.6.25 subject Parameter subject
:reference
The subject of the Imaging Selection, such as the associated Patient
Resource ImagingSelection
Expression
ImagingSelection.subject
Processing Mode
Normal
Target Resources
Device , Procedure , Group , Practitioner , Specimen , Substance , Patient , Medication
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true