IDEA4RC FHIR Implementation Guide, published by IDEA4RC Project. This guide is not an authorized publication; it is the continuous build for version 0.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7-eu/idea4rc/ and changes regularly. See the Directory of published versions
Official URL: http://hl7.eu/fhir/ig/idea4rc/StructureDefinition/radiotherapy-energy-or-isotope | Version: 0.1.0 | |||
Draft as of 2024-11-12 | Computable Name: RadiotherapyEnergyOrIsotope |
The radiation energy used for radiotherapy. The energy spectrum is characterized by the maximum energy, the maximum accelaration voltage, or the used isotope. This extension is based on the CodeX™ Radiation Therapy RadiotherapyEnergyOrIsotope extension
Context of Use
This extension may be used on the following element(s):
Usage info
Usage:
Description of Profiles, Differentials, Snapshots, and how the XML and JSON presentations work.
This structure is derived from Extension
Summary
Simple Extension of type CodeableConcept, Quantity: The radiation energy used for radiotherapy. The energy spectrum is characterized by the maximum energy, the maximum accelaration voltage, or the used isotope. This extension is based on the CodeX™ Radiation Therapy RadiotherapyEnergyOrIsotope extension
This structure is derived from Extension
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Extension | 0..* | Extension | Radiotherapy Energy or Isotope | |
extension | 0..0 | |||
url | 1..1 | uri | "http://hl7.eu/fhir/ig/idea4rc/StructureDefinition/radiotherapy-energy-or-isotope" | |
Slices for value[x] | 1..1 | Value of extension Slice: Unordered, Open by type:$this | ||
valueCodeableConcept | CodeableConcept | |||
valueQuantity | Quantity(SimpleQuantity) | |||
value[x]:valueQuantity | 0..1 | SimpleQuantity | The spectrum of radiation energy characterized by a maximum value. For electrons, the maximum energy is given in MeV. For photons, the maximum acceleration voltage is given in MV or kV, although those are not units of energy. | |
value[x]:valueCodeableConcept | 0..1 | CodeableConcept | The isotope used for radiotherapy. | |
Documentation for this format |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Extension | 0..* | Extension | Radiotherapy Energy or Isotope | |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..0 | |||
url | 1..1 | uri | "http://hl7.eu/fhir/ig/idea4rc/StructureDefinition/radiotherapy-energy-or-isotope" | |
Slices for value[x] | 1..1 | Value of extension Slice: Unordered, Closed by type:$this | ||
valueCodeableConcept | CodeableConcept | |||
valueQuantity | Quantity(SimpleQuantity) | |||
value[x]:valueQuantity | C | 0..1 | SimpleQuantity | The spectrum of radiation energy characterized by a maximum value.
For electrons, the maximum energy is given in MeV. For photons, the maximum acceleration voltage is given in MV or kV, although those are not units of energy. qty-3: If a code for the unit is present, the system SHALL also be present |
value[x]:valueCodeableConcept | 0..1 | CodeableConcept | The isotope used for radiotherapy. | |
Documentation for this format |
This structure is derived from Extension
Summary
Simple Extension of type CodeableConcept, Quantity: The radiation energy used for radiotherapy. The energy spectrum is characterized by the maximum energy, the maximum accelaration voltage, or the used isotope. This extension is based on the CodeX™ Radiation Therapy RadiotherapyEnergyOrIsotope extension
Differential View
This structure is derived from Extension
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Extension | 0..* | Extension | Radiotherapy Energy or Isotope | |
extension | 0..0 | |||
url | 1..1 | uri | "http://hl7.eu/fhir/ig/idea4rc/StructureDefinition/radiotherapy-energy-or-isotope" | |
Slices for value[x] | 1..1 | Value of extension Slice: Unordered, Open by type:$this | ||
valueCodeableConcept | CodeableConcept | |||
valueQuantity | Quantity(SimpleQuantity) | |||
value[x]:valueQuantity | 0..1 | SimpleQuantity | The spectrum of radiation energy characterized by a maximum value. For electrons, the maximum energy is given in MeV. For photons, the maximum acceleration voltage is given in MV or kV, although those are not units of energy. | |
value[x]:valueCodeableConcept | 0..1 | CodeableConcept | The isotope used for radiotherapy. | |
Documentation for this format |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Extension | 0..* | Extension | Radiotherapy Energy or Isotope | |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..0 | |||
url | 1..1 | uri | "http://hl7.eu/fhir/ig/idea4rc/StructureDefinition/radiotherapy-energy-or-isotope" | |
Slices for value[x] | 1..1 | Value of extension Slice: Unordered, Closed by type:$this | ||
valueCodeableConcept | CodeableConcept | |||
valueQuantity | Quantity(SimpleQuantity) | |||
value[x]:valueQuantity | C | 0..1 | SimpleQuantity | The spectrum of radiation energy characterized by a maximum value.
For electrons, the maximum energy is given in MeV. For photons, the maximum acceleration voltage is given in MV or kV, although those are not units of energy. qty-3: If a code for the unit is present, the system SHALL also be present |
value[x]:valueCodeableConcept | 0..1 | CodeableConcept | The isotope used for radiotherapy. | |
Documentation for this format |
Other representations of profile: CSV, Excel, Schematron