Vital Signs Cross-Country Cross-Language Cross-Paradigm (Demo) IG
0.5.4 - ci-build

Vital Signs Cross-Country Cross-Language Cross-Paradigm (Demo) IG, published by FO. This guide is not an authorized publication; it is the continuous build for version 0.5.4 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/frankoemig/vital-signs-demo/ and changes regularly. See the Directory of published versions

Logical Model: Blood Pressure Systolic (Profile) in v2

Official URL: http://vitals.oemig.de/fhir/StructureDefinition/OBXsystolicBP Version: 0.5.4
Active as of 2024-04-16 Computable Name: OBXsystolicBP

Copyright/Legal: FO

v2 Profile: Systolic Blood Pressure

Usage:

  • This Logical Model is not used by any profiles in this Implementation Guide

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

This structure is derived from OBXsegment

NameFlagsCard.TypeDescription & Constraintsdoco
.. OBXsegment 0..* OBXsegment
Elements defined in Ancestors:seqNo, valueDataType, observationCode, observationGroup, value, unit, referenceRange, interpretation, observationDateTime, responsibleObserver, observationSite, observationAbsentReason
OBX Segment LM
Instances of this logical model are not marked to be the target of a Reference
... seqNo 0..1 integer Sequence Number (OBX-1)
Required Pattern: 2
... valueDataType S 0..1 CodeableConcept Data Type (OBX-2)
Required Pattern: At least the following
.... coding 1..* Coding Code defined by a terminology system
Fixed Value: (complex)
..... system 1..1 uri Identity of the terminology system
Fixed Value: http://vitals.oemig.de/fhir/CodeSystem/v2code
..... code 1..1 code Symbol in syntax defined by the system
Fixed Value: NM
... observationCode S 0..* CodeableConcept code for observed value (OBX-3)
Binding: Vital Signs Systolic Blood Pressure Codes (required)

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSetURI
OBXsegment.observationCoderequiredUSCoreSystolicBloodPressureCodes
http://vitals.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code
from this IG
NameFlagsCard.TypeDescription & Constraintsdoco
.. OBXsegment 0..* OBXsegment
Elements defined in Ancestors:seqNo, valueDataType, observationCode, observationGroup, value, unit, referenceRange, interpretation, observationDateTime, responsibleObserver, observationSite, observationAbsentReason
OBX Segment LM
Instances of this logical model are not marked to be the target of a Reference
... seqNo 0..1 integer Sequence Number (OBX-1)
Required Pattern: 2
... valueDataType S 0..1 CodeableConcept Data Type (OBX-2)
Required Pattern: At least the following
.... coding 1..* Coding Code defined by a terminology system
Fixed Value: (complex)
..... system 1..1 uri Identity of the terminology system
Fixed Value: http://vitals.oemig.de/fhir/CodeSystem/v2code
..... code 1..1 code Symbol in syntax defined by the system
Fixed Value: NM
... observationCode S 0..* CodeableConcept code for observed value (OBX-3)
Binding: Vital Signs Systolic Blood Pressure Codes (required)
... unit 1..1 CodeableConcept units (OBX-6)

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
OBXsegment.observationCoderequiredUSCoreSystolicBloodPressureCodes
http://vitals.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code
from this IG
NameFlagsCard.TypeDescription & Constraintsdoco
.. OBXsegment 0..* OBXsegment
Elements defined in Ancestors:seqNo, valueDataType, observationCode, observationGroup, value, unit, referenceRange, interpretation, observationDateTime, responsibleObserver, observationSite, observationAbsentReason
OBX Segment LM
Instances of this logical model are not marked to be the target of a Reference
... seqNo 0..1 integer Sequence Number (OBX-1)
Required Pattern: 2
... valueDataType S 0..1 CodeableConcept Data Type (OBX-2)
Required Pattern: At least the following
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... coding 1..* Coding Code defined by a terminology system
Fixed Value: (complex)
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... system 1..1 uri Identity of the terminology system
Fixed Value: http://vitals.oemig.de/fhir/CodeSystem/v2code
..... version 0..1 string Version of the system - if relevant
..... code 1..1 code Symbol in syntax defined by the system
Fixed Value: NM
..... display 0..1 string Representation defined by the system
..... userSelected 0..1 boolean If this coding was chosen directly by the user
.... text 0..1 string Plain text representation of the concept
... observationCode S 0..* CodeableConcept code for observed value (OBX-3)
Binding: Vital Signs Systolic Blood Pressure Codes (required)
... value S 0..* integer observed/measured value (OBX-5)
... unit 1..1 CodeableConcept units (OBX-6)
... referenceRange 0..1 CodeableConcept reference range for values (OBX-7)
... interpretation 0..1 CodeableConcept interpretation code (OBX-8)
... observationDateTime 0..1 instant Diagnosis Date/Time (OBX-14)
... responsibleObserver 0..1 Reference(Practitioner) responsible observer (OBX-16)
... observationSite 0..1 CodeableConcept body structure (OBX-20)
... observationAbsentReason 0..1 CodeableConcept data absent reason (OBX-32)

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
OBXsegment.observationCoderequiredUSCoreSystolicBloodPressureCodes
http://vitals.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code
from this IG

This structure is derived from OBXsegment

Summary

Must-Support: 3 elements

Differential View

This structure is derived from OBXsegment

NameFlagsCard.TypeDescription & Constraintsdoco
.. OBXsegment 0..* OBXsegment
Elements defined in Ancestors:seqNo, valueDataType, observationCode, observationGroup, value, unit, referenceRange, interpretation, observationDateTime, responsibleObserver, observationSite, observationAbsentReason
OBX Segment LM
Instances of this logical model are not marked to be the target of a Reference
... seqNo 0..1 integer Sequence Number (OBX-1)
Required Pattern: 2
... valueDataType S 0..1 CodeableConcept Data Type (OBX-2)
Required Pattern: At least the following
.... coding 1..* Coding Code defined by a terminology system
Fixed Value: (complex)
..... system 1..1 uri Identity of the terminology system
Fixed Value: http://vitals.oemig.de/fhir/CodeSystem/v2code
..... code 1..1 code Symbol in syntax defined by the system
Fixed Value: NM
... observationCode S 0..* CodeableConcept code for observed value (OBX-3)
Binding: Vital Signs Systolic Blood Pressure Codes (required)

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSetURI
OBXsegment.observationCoderequiredUSCoreSystolicBloodPressureCodes
http://vitals.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code
from this IG

Key Elements View

NameFlagsCard.TypeDescription & Constraintsdoco
.. OBXsegment 0..* OBXsegment
Elements defined in Ancestors:seqNo, valueDataType, observationCode, observationGroup, value, unit, referenceRange, interpretation, observationDateTime, responsibleObserver, observationSite, observationAbsentReason
OBX Segment LM
Instances of this logical model are not marked to be the target of a Reference
... seqNo 0..1 integer Sequence Number (OBX-1)
Required Pattern: 2
... valueDataType S 0..1 CodeableConcept Data Type (OBX-2)
Required Pattern: At least the following
.... coding 1..* Coding Code defined by a terminology system
Fixed Value: (complex)
..... system 1..1 uri Identity of the terminology system
Fixed Value: http://vitals.oemig.de/fhir/CodeSystem/v2code
..... code 1..1 code Symbol in syntax defined by the system
Fixed Value: NM
... observationCode S 0..* CodeableConcept code for observed value (OBX-3)
Binding: Vital Signs Systolic Blood Pressure Codes (required)
... unit 1..1 CodeableConcept units (OBX-6)

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
OBXsegment.observationCoderequiredUSCoreSystolicBloodPressureCodes
http://vitals.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code
from this IG

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. OBXsegment 0..* OBXsegment
Elements defined in Ancestors:seqNo, valueDataType, observationCode, observationGroup, value, unit, referenceRange, interpretation, observationDateTime, responsibleObserver, observationSite, observationAbsentReason
OBX Segment LM
Instances of this logical model are not marked to be the target of a Reference
... seqNo 0..1 integer Sequence Number (OBX-1)
Required Pattern: 2
... valueDataType S 0..1 CodeableConcept Data Type (OBX-2)
Required Pattern: At least the following
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... coding 1..* Coding Code defined by a terminology system
Fixed Value: (complex)
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... system 1..1 uri Identity of the terminology system
Fixed Value: http://vitals.oemig.de/fhir/CodeSystem/v2code
..... version 0..1 string Version of the system - if relevant
..... code 1..1 code Symbol in syntax defined by the system
Fixed Value: NM
..... display 0..1 string Representation defined by the system
..... userSelected 0..1 boolean If this coding was chosen directly by the user
.... text 0..1 string Plain text representation of the concept
... observationCode S 0..* CodeableConcept code for observed value (OBX-3)
Binding: Vital Signs Systolic Blood Pressure Codes (required)
... value S 0..* integer observed/measured value (OBX-5)
... unit 1..1 CodeableConcept units (OBX-6)
... referenceRange 0..1 CodeableConcept reference range for values (OBX-7)
... interpretation 0..1 CodeableConcept interpretation code (OBX-8)
... observationDateTime 0..1 instant Diagnosis Date/Time (OBX-14)
... responsibleObserver 0..1 Reference(Practitioner) responsible observer (OBX-16)
... observationSite 0..1 CodeableConcept body structure (OBX-20)
... observationAbsentReason 0..1 CodeableConcept data absent reason (OBX-32)

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
OBXsegment.observationCoderequiredUSCoreSystolicBloodPressureCodes
http://vitals.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code
from this IG

This structure is derived from OBXsegment

Summary

Must-Support: 3 elements

 

Other representations of profile: CSV, Excel