Vital Signs Cross-Country Cross-Language Cross-Paradigm (Demo) IG, published by FO. This guide is not an authorized publication; it is the continuous build for version 0.6.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/frankoemig/vital-signs-demo/ and changes regularly. See the Directory of published versions

Use of LOINC

This obstacle discusses the use of LOINC codes:

It appears that the LOINC codes are somehow incomplete in their definition. Let's take arterial systolic BP as an example:

LOINC Long Common Name Component Property Timing System Scale Method Class Example UCUM Units Order/Observation
86908-1 Systolic blood pressure goal Intravascular systolic goal Pres Pt Arterial system Qn   CLIN mm[Hg] Both
8450-9 Systolic blood pressure–expiration Intravascular systolic^expiration Pres Pt Arterial system Qn   BP.MOLEC mm[Hg]  
89280-2 Systolic blood pressure–during anesthesia Intravascular systolic^during anesthesia Pres Pt Arterial system Qn   BP.MOLEC mm[Hg] Both
8451-7 Systolic blood pressure–inspiration Intravascular systolic^inspiration Pres Pt Arterial system Qn   BP.MOLEC mm[Hg]  
89268-7 Systolic blood pressure–lying in L-lateral position Intravascular systolic^lying in L-lateral position Pres Pt Arterial system Qn   BP.MOLEC mm[Hg] Both
87741-5 Systolic blood pressure–post exercise Intravascular systolic^post exercise Pres Pt Arterial system Qn   BP.MOLEC mm[Hg] Both
8459-0 Systolic blood pressure–sitting Intravascular systolic^sitting Pres Pt Arterial system Qn   BP.PSTN.MOLEC mm[Hg]  
8460-8 Systolic blood pressure–standing Intravascular systolic^standing Pres Pt Arterial system Qn   BP.PSTN.MOLEC mm[Hg]  
8461-6 Systolic blood pressure–supine Intravascular systolic^supine Pres Pt Arterial system Qn   BP.PSTN.MOLEC mm[Hg]  
87739-9 Systolic blood pressure–W exercise Intravascular systolic^W exercise Pres Pt Arterial system Qn   BP.MOLEC mm[Hg] Both
8452-5 Systolic blood pressure.inspiration - expiration Intravascular systolic.inspiration - expiration Pres Pt Arterial system Qn   BP.MOLEC mm[Hg]  

8480-8 cannot act as a parent code for all type of systolic measurements within the above group because the others are not real specialisations. Doing some exercising normally leads to an increase of the measured value. The reference range is also increased influencing the interpretation. So, without knowing the context a correct interpretation is not possible.