Resumen Clínico del Paciente de Chile, published by HL7 Chile. This guide is not an authorized publication; it is the continuous build for version 0.5.0-ci-build built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7Chile/IPS-CL/ and changes regularly. See the Directory of published versions

Resource Profile: Dispositivo

Official URL: https://hl7chile.cl/fhir/ig/clips/StructureDefinition/Dispositivo-cl-ips Version: 0.5.0-ci-build
Standards status: Draft Maturity Level: 1 Computable Name: DispositivoClIps

Este perfil representa las restricciones aplicadas al recurso Device por la Guía de implementación de FHIR del Resumen Internacional del Paciente Adaptación de Chile . Un dispositivo utilizado por el paciente o implantado en él se describe como una instancia del recurso Device restringido por este perfil.

Este perfil restringe la representación de un dispositivo médico utilizado o implantado en el paciente, en el contexto del resumen internacional del paciente según lo especificado por el proyecto IPS de HL7 Chile.

Usages:

You can also check for usages in the FHIR IG Statistics

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Device 0..* Device Item used in healthcare
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... status ?!Σ 0..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.
... patient S 1..1 Reference(Paciente) Paciente al que está adherido el dispositivo
.... reference SΣC 1..1 string Referencia literal, interna o url absoluta

doco Documentation for this format

Terminology Bindings

Path Status Usage ValueSet Version Source
Device.status Base required FHIRDeviceStatus 📍4.0.1 FHIR Std.
Device.type Base preferred Medical Devices - IPS 📍2.0.0 International Patient Summary Implementation Guide v2.0

Constraints

Id Grade Path(s) Description Expression
dom-2 error Device If the resource is contained in another resource, it SHALL NOT contain nested Resources contained.contained.empty()
dom-3 error Device If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4 error Device If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5 error Device If a resource is contained in another resource, it SHALL NOT have a security label contained.meta.security.empty()
dom-6 best practice Device A resource should have narrative for robust management text.`div`.exists()
ele-1 error **ALL** elements All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error **ALL** extensions Must have either extensions or value[x], not both extension.exists() != value.exists()

This structure is derived from Device

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Device Device
... type S 0..1 CodeableConceptIPS(2.0.0) Tipo de dispositivo.
Binding: MedicalDevicesUvIps (2.0.0) (preferred): Tipo de dispositivo o un código en caso de dispositivo ausente/desconocido.
... patient S 1..1 Reference(Paciente) Paciente al que está adherido el dispositivo
.... reference S 1..1 string Referencia literal, interna o url absoluta

doco Documentation for this format

Terminology Bindings (Differential)

Path Status Usage ValueSet Version Source
Device.type Base preferred Medical Devices - IPS 📍2.0.0 International Patient Summary Implementation Guide v2.0
NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Device 0..* Device Item used in healthcare
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... language 0..1 code Language of the resource content
Binding: CommonLanguages (preferred): A human language.
Additional BindingsPurpose
AllLanguages Max Binding
... text 0..1 Narrative Text summary of the resource, for human interpretation
This profile does not constrain the narrative in regard to content, language, or traceability to data elements
... contained 0..* Resource Contained, inline Resources
... extension 0..* Extension Additional content defined by implementations
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier 0..* Identifier Instance identifier
... definition 0..1 Reference(DeviceDefinition) The reference to the definition for the device
... udiCarrier Σ 0..* BackboneElement Unique Device Identifier (UDI) Barcode string
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... deviceIdentifier Σ 0..1 string Mandatory fixed portion of UDI
.... issuer 0..1 uri UDI Issuing Organization
.... jurisdiction 0..1 uri Regional UDI authority
.... carrierAIDC Σ 0..1 base64Binary UDI Machine Readable Barcode String
.... carrierHRF Σ 0..1 string UDI Human Readable Barcode String
.... entryType 0..1 code barcode | rfid | manual +
Binding: UDIEntryType (required): Codes to identify how UDI data was entered.
... status ?!Σ 0..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.
... statusReason 0..* CodeableConcept online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device.
... distinctIdentifier 0..1 string The distinct identification string
... manufacturer 0..1 string Name of device manufacturer
... manufactureDate 0..1 dateTime Date when the device was made
... expirationDate 0..1 dateTime Date and time of expiry of this device (if applicable)
... lotNumber 0..1 string Lot number of manufacture
... serialNumber 0..1 string Serial number assigned by the manufacturer
... deviceName 0..* BackboneElement The name of the device as given by the manufacturer
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... name 1..1 string The name of the device
.... type 1..1 code udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.
... modelNumber 0..1 string The model number for the device
... partNumber 0..1 string The part number of the device
... type S 0..1 CodeableConceptIPS(2.0.0) Tipo de dispositivo.
Binding: MedicalDevicesUvIps (2.0.0) (preferred): Tipo de dispositivo o un código en caso de dispositivo ausente/desconocido.
... specialization 0..* BackboneElement The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... systemType 1..1 CodeableConcept The standard that is used to operate and communicate
.... version 0..1 string The version of the standard that is used to operate and communicate
... version 0..* BackboneElement The actual design of the device or software version running on the device
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... type 0..1 CodeableConcept The type of the device version
.... component 0..1 Identifier A single component of the device version
.... value 1..1 string The version text
... property 0..* BackboneElement The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... type 1..1 CodeableConcept Code that specifies the property DeviceDefinitionPropetyCode (Extensible)
.... valueQuantity 0..* Quantity Property value as a quantity
.... valueCode 0..* CodeableConcept Property value as a code, e.g., NTP4 (synced to NTP)
... patient S 1..1 Reference(Paciente) Paciente al que está adherido el dispositivo
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... reference SΣC 1..1 string Referencia literal, interna o url absoluta
.... type Σ 0..1 uri Type the reference refers to (e.g. "Patient")
Binding: ResourceType (extensible): Aa resource (or, for logical models, the URI of the logical model).
.... identifier Σ 0..1 Identifier Logical reference, when literal reference is not known
.... display Σ 0..1 string Text alternative for the resource
... owner 0..1 Reference(Organization) Organization responsible for device
... contact 0..* ContactPoint Details for human/organization for support
... location 0..1 Reference(Location) Where the device is found
... url 0..1 uri Network address to contact device
... note 0..* Annotation Device notes and comments
... safety Σ 0..* CodeableConcept Safety Characteristics of Device
... parent 0..1 Reference(Device) The parent device

doco Documentation for this format

Terminology Bindings

Path Status Usage ValueSet Version Source
Device.language Base preferred Common Languages 📍4.0.1 FHIR Std.
Device.udiCarrier.entryType Base required UDIEntryType 📍4.0.1 FHIR Std.
Device.status Base required FHIRDeviceStatus 📍4.0.1 FHIR Std.
Device.statusReason Base extensible FHIRDeviceStatusReason 📍4.0.1 FHIR Std.
Device.deviceName.type Base required DeviceNameType 📍4.0.1 FHIR Std.
Device.type Base preferred Medical Devices - IPS 📍2.0.0 International Patient Summary Implementation Guide v2.0
Device.patient.type Base extensible ResourceType 📍4.0.1 FHIR Std.

Constraints

Id Grade Path(s) Description Expression
dom-2 error Device If the resource is contained in another resource, it SHALL NOT contain nested Resources contained.contained.empty()
dom-3 error Device If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4 error Device If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5 error Device If a resource is contained in another resource, it SHALL NOT have a security label contained.meta.security.empty()
dom-6 best practice Device A resource should have narrative for robust management text.`div`.exists()
ele-1 error **ALL** elements All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error **ALL** extensions Must have either extensions or value[x], not both extension.exists() != value.exists()

This structure is derived from Device

Key Elements View

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Device 0..* Device Item used in healthcare
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... status ?!Σ 0..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.
... patient S 1..1 Reference(Paciente) Paciente al que está adherido el dispositivo
.... reference SΣC 1..1 string Referencia literal, interna o url absoluta

doco Documentation for this format

Terminology Bindings

Path Status Usage ValueSet Version Source
Device.status Base required FHIRDeviceStatus 📍4.0.1 FHIR Std.
Device.type Base preferred Medical Devices - IPS 📍2.0.0 International Patient Summary Implementation Guide v2.0

Constraints

Id Grade Path(s) Description Expression
dom-2 error Device If the resource is contained in another resource, it SHALL NOT contain nested Resources contained.contained.empty()
dom-3 error Device If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4 error Device If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5 error Device If a resource is contained in another resource, it SHALL NOT have a security label contained.meta.security.empty()
dom-6 best practice Device A resource should have narrative for robust management text.`div`.exists()
ele-1 error **ALL** elements All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error **ALL** extensions Must have either extensions or value[x], not both extension.exists() != value.exists()

Differential View

This structure is derived from Device

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Device Device
... type S 0..1 CodeableConceptIPS(2.0.0) Tipo de dispositivo.
Binding: MedicalDevicesUvIps (2.0.0) (preferred): Tipo de dispositivo o un código en caso de dispositivo ausente/desconocido.
... patient S 1..1 Reference(Paciente) Paciente al que está adherido el dispositivo
.... reference S 1..1 string Referencia literal, interna o url absoluta

doco Documentation for this format

Terminology Bindings (Differential)

Path Status Usage ValueSet Version Source
Device.type Base preferred Medical Devices - IPS 📍2.0.0 International Patient Summary Implementation Guide v2.0

Snapshot View

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Device 0..* Device Item used in healthcare
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... language 0..1 code Language of the resource content
Binding: CommonLanguages (preferred): A human language.
Additional BindingsPurpose
AllLanguages Max Binding
... text 0..1 Narrative Text summary of the resource, for human interpretation
This profile does not constrain the narrative in regard to content, language, or traceability to data elements
... contained 0..* Resource Contained, inline Resources
... extension 0..* Extension Additional content defined by implementations
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier 0..* Identifier Instance identifier
... definition 0..1 Reference(DeviceDefinition) The reference to the definition for the device
... udiCarrier Σ 0..* BackboneElement Unique Device Identifier (UDI) Barcode string
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... deviceIdentifier Σ 0..1 string Mandatory fixed portion of UDI
.... issuer 0..1 uri UDI Issuing Organization
.... jurisdiction 0..1 uri Regional UDI authority
.... carrierAIDC Σ 0..1 base64Binary UDI Machine Readable Barcode String
.... carrierHRF Σ 0..1 string UDI Human Readable Barcode String
.... entryType 0..1 code barcode | rfid | manual +
Binding: UDIEntryType (required): Codes to identify how UDI data was entered.
... status ?!Σ 0..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.
... statusReason 0..* CodeableConcept online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device.
... distinctIdentifier 0..1 string The distinct identification string
... manufacturer 0..1 string Name of device manufacturer
... manufactureDate 0..1 dateTime Date when the device was made
... expirationDate 0..1 dateTime Date and time of expiry of this device (if applicable)
... lotNumber 0..1 string Lot number of manufacture
... serialNumber 0..1 string Serial number assigned by the manufacturer
... deviceName 0..* BackboneElement The name of the device as given by the manufacturer
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... name 1..1 string The name of the device
.... type 1..1 code udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.
... modelNumber 0..1 string The model number for the device
... partNumber 0..1 string The part number of the device
... type S 0..1 CodeableConceptIPS(2.0.0) Tipo de dispositivo.
Binding: MedicalDevicesUvIps (2.0.0) (preferred): Tipo de dispositivo o un código en caso de dispositivo ausente/desconocido.
... specialization 0..* BackboneElement The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... systemType 1..1 CodeableConcept The standard that is used to operate and communicate
.... version 0..1 string The version of the standard that is used to operate and communicate
... version 0..* BackboneElement The actual design of the device or software version running on the device
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... type 0..1 CodeableConcept The type of the device version
.... component 0..1 Identifier A single component of the device version
.... value 1..1 string The version text
... property 0..* BackboneElement The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... type 1..1 CodeableConcept Code that specifies the property DeviceDefinitionPropetyCode (Extensible)
.... valueQuantity 0..* Quantity Property value as a quantity
.... valueCode 0..* CodeableConcept Property value as a code, e.g., NTP4 (synced to NTP)
... patient S 1..1 Reference(Paciente) Paciente al que está adherido el dispositivo
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... reference SΣC 1..1 string Referencia literal, interna o url absoluta
.... type Σ 0..1 uri Type the reference refers to (e.g. "Patient")
Binding: ResourceType (extensible): Aa resource (or, for logical models, the URI of the logical model).
.... identifier Σ 0..1 Identifier Logical reference, when literal reference is not known
.... display Σ 0..1 string Text alternative for the resource
... owner 0..1 Reference(Organization) Organization responsible for device
... contact 0..* ContactPoint Details for human/organization for support
... location 0..1 Reference(Location) Where the device is found
... url 0..1 uri Network address to contact device
... note 0..* Annotation Device notes and comments
... safety Σ 0..* CodeableConcept Safety Characteristics of Device
... parent 0..1 Reference(Device) The parent device

doco Documentation for this format

Terminology Bindings

Path Status Usage ValueSet Version Source
Device.language Base preferred Common Languages 📍4.0.1 FHIR Std.
Device.udiCarrier.entryType Base required UDIEntryType 📍4.0.1 FHIR Std.
Device.status Base required FHIRDeviceStatus 📍4.0.1 FHIR Std.
Device.statusReason Base extensible FHIRDeviceStatusReason 📍4.0.1 FHIR Std.
Device.deviceName.type Base required DeviceNameType 📍4.0.1 FHIR Std.
Device.type Base preferred Medical Devices - IPS 📍2.0.0 International Patient Summary Implementation Guide v2.0
Device.patient.type Base extensible ResourceType 📍4.0.1 FHIR Std.

Constraints

Id Grade Path(s) Description Expression
dom-2 error Device If the resource is contained in another resource, it SHALL NOT contain nested Resources contained.contained.empty()
dom-3 error Device If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4 error Device If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5 error Device If a resource is contained in another resource, it SHALL NOT have a security label contained.meta.security.empty()
dom-6 best practice Device A resource should have narrative for robust management text.`div`.exists()
ele-1 error **ALL** elements All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error **ALL** extensions Must have either extensions or value[x], not both extension.exists() != value.exists()

This structure is derived from Device

 

Other representations of profile: CSV, Excel, Schematron