Clinical Document Architecture
2.0.0-sd - release

Clinical Document Architecture, published by Health Level 7. This guide is not an authorized publication; it is the continuous build for version 2.0.0-sd built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/CDA-core-sd/ and changes regularly. See the Directory of published versions

Logical Model: Device (CDA Class)

Official URL: http://hl7.org/cda/stds/core/StructureDefinition/Device Version: 2.0.0-sd
Active as of 2024-10-25 Computable Name: Device

A ManufacturedMaterial used in an activity without being substantially changed through that activity.

This includes durable (reusable) medical equipment as well as disposable equipment. The kind of device is identified by the code attribute inherited from Entity.

Usage:

Formal Views of Template Content

Description of Template, Differentials, Snapshots and how the different presentations work.

This structure is derived from InfrastructureRoot

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 1..1 InfrastructureRoot XML Namespace: urn:hl7-org:v3
Elements defined in Ancestors:@nullFlavor, realmCode, typeId, templateId
Base for all types and resources
Instance of this type are validated by templateId
Logical Container: ClinicalDocument (CDA Class)
... @classCode 0..1 cs Binding: EntityClassDevice (required)
... @determinerCode 0..1 cs Binding: EntityDeterminer (required)
Fixed Value: INSTANCE
... code 0..1 CE Binding: CDAEntityCode (example)
... softwareName 0..1 SC Binding: Software Name Example (example)

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSet / CodeURI
Device.classCoderequiredEntityClassDevice
http://terminology.hl7.org/ValueSet/v3-EntityClassDevice
Device.determinerCoderequiredFixed Value: INSTANCE
http://terminology.hl7.org/ValueSet/v3-EntityDeterminer
Device.codeexampleCDAEntityCode
http://hl7.org/cda/stds/core/ValueSet/CDAEntityCode
from this IG
Device.manufacturerModelNameexampleManufacturerModelNameExample
http://terminology.hl7.org/ValueSet/v3-ManufacturerModelNameExample
Device.softwareNameexampleSoftwareNameExample
http://terminology.hl7.org/ValueSet/v3-SoftwareNameExample
NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 1..1 InfrastructureRoot XML Namespace: urn:hl7-org:v3
Elements defined in Ancestors:@nullFlavor, realmCode, typeId, templateId
Base for all types and resources
Instance of this type are validated by templateId
Logical Container: ClinicalDocument (CDA Class)
... @classCode 0..1 cs Binding: EntityClassDevice (required)
... @determinerCode 0..1 cs Binding: EntityDeterminer (required)
Fixed Value: INSTANCE
... code 0..1 CE Binding: CDAEntityCode (example)
... softwareName 0..1 SC Binding: Software Name Example (example)

doco Documentation for this format

Terminology Bindings

PathConformanceValueSet / CodeURI
Device.classCoderequiredEntityClassDevice
http://terminology.hl7.org/ValueSet/v3-EntityClassDevice
Device.determinerCoderequiredFixed Value: INSTANCE
http://terminology.hl7.org/ValueSet/v3-EntityDeterminer
Device.codeexampleCDAEntityCode
http://hl7.org/cda/stds/core/ValueSet/CDAEntityCode
from this IG
Device.manufacturerModelNameexampleManufacturerModelNameExample
http://terminology.hl7.org/ValueSet/v3-ManufacturerModelNameExample
Device.softwareNameexampleSoftwareNameExample
http://terminology.hl7.org/ValueSet/v3-SoftwareNameExample
NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 1..1 InfrastructureRoot XML Namespace: urn:hl7-org:v3
Elements defined in Ancestors:@nullFlavor, realmCode, typeId, templateId
Base for all types and resources
Instance of this type are validated by templateId
Logical Container: ClinicalDocument (CDA Class)
... @nullFlavor 0..1 cs Binding: CDANullFlavor (required)
... realmCode 0..* CS
... typeId 0..1 II
.... @nullFlavor 0..1 cs Binding: CDANullFlavor (required)
.... @assigningAuthorityName 0..1 st
.... @displayable 0..1 bl
.... @root 1..1 oid, uuid, ruid Fixed Value: 2.16.840.1.113883.1.3
.... @extension 1..1 st
... @classCode 0..1 cs Binding: EntityClassDevice (required)
... @determinerCode 0..1 cs Binding: EntityDeterminer (required)
Fixed Value: INSTANCE
... code 0..1 CE Binding: CDAEntityCode (example)
... manufacturerModelName 0..1 SC Binding: Manufacturer Model Name Example (example)
... softwareName 0..1 SC Binding: Software Name Example (example)

doco Documentation for this format

Terminology Bindings

PathConformanceValueSet / CodeURI
Device.nullFlavorrequiredCDANullFlavor
http://hl7.org/cda/stds/core/ValueSet/CDANullFlavor
from this IG
Device.typeId.nullFlavorrequiredCDANullFlavor
http://hl7.org/cda/stds/core/ValueSet/CDANullFlavor
from this IG
Device.classCoderequiredEntityClassDevice
http://terminology.hl7.org/ValueSet/v3-EntityClassDevice
Device.determinerCoderequiredFixed Value: INSTANCE
http://terminology.hl7.org/ValueSet/v3-EntityDeterminer
Device.codeexampleCDAEntityCode
http://hl7.org/cda/stds/core/ValueSet/CDAEntityCode
from this IG
Device.manufacturerModelNameexampleManufacturerModelNameExample
http://terminology.hl7.org/ValueSet/v3-ManufacturerModelNameExample
Device.softwareNameexampleSoftwareNameExample
http://terminology.hl7.org/ValueSet/v3-SoftwareNameExample

This structure is derived from InfrastructureRoot

Summary

Fixed: 1 element

Structures

This structure refers to these other structures:

Differential View

This structure is derived from InfrastructureRoot

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 1..1 InfrastructureRoot XML Namespace: urn:hl7-org:v3
Elements defined in Ancestors:@nullFlavor, realmCode, typeId, templateId
Base for all types and resources
Instance of this type are validated by templateId
Logical Container: ClinicalDocument (CDA Class)
... @classCode 0..1 cs Binding: EntityClassDevice (required)
... @determinerCode 0..1 cs Binding: EntityDeterminer (required)
Fixed Value: INSTANCE
... code 0..1 CE Binding: CDAEntityCode (example)
... softwareName 0..1 SC Binding: Software Name Example (example)

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSet / CodeURI
Device.classCoderequiredEntityClassDevice
http://terminology.hl7.org/ValueSet/v3-EntityClassDevice
Device.determinerCoderequiredFixed Value: INSTANCE
http://terminology.hl7.org/ValueSet/v3-EntityDeterminer
Device.codeexampleCDAEntityCode
http://hl7.org/cda/stds/core/ValueSet/CDAEntityCode
from this IG
Device.manufacturerModelNameexampleManufacturerModelNameExample
http://terminology.hl7.org/ValueSet/v3-ManufacturerModelNameExample
Device.softwareNameexampleSoftwareNameExample
http://terminology.hl7.org/ValueSet/v3-SoftwareNameExample

Key Elements View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 1..1 InfrastructureRoot XML Namespace: urn:hl7-org:v3
Elements defined in Ancestors:@nullFlavor, realmCode, typeId, templateId
Base for all types and resources
Instance of this type are validated by templateId
Logical Container: ClinicalDocument (CDA Class)
... @classCode 0..1 cs Binding: EntityClassDevice (required)
... @determinerCode 0..1 cs Binding: EntityDeterminer (required)
Fixed Value: INSTANCE
... code 0..1 CE Binding: CDAEntityCode (example)
... softwareName 0..1 SC Binding: Software Name Example (example)

doco Documentation for this format

Terminology Bindings

PathConformanceValueSet / CodeURI
Device.classCoderequiredEntityClassDevice
http://terminology.hl7.org/ValueSet/v3-EntityClassDevice
Device.determinerCoderequiredFixed Value: INSTANCE
http://terminology.hl7.org/ValueSet/v3-EntityDeterminer
Device.codeexampleCDAEntityCode
http://hl7.org/cda/stds/core/ValueSet/CDAEntityCode
from this IG
Device.manufacturerModelNameexampleManufacturerModelNameExample
http://terminology.hl7.org/ValueSet/v3-ManufacturerModelNameExample
Device.softwareNameexampleSoftwareNameExample
http://terminology.hl7.org/ValueSet/v3-SoftwareNameExample

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 1..1 InfrastructureRoot XML Namespace: urn:hl7-org:v3
Elements defined in Ancestors:@nullFlavor, realmCode, typeId, templateId
Base for all types and resources
Instance of this type are validated by templateId
Logical Container: ClinicalDocument (CDA Class)
... @nullFlavor 0..1 cs Binding: CDANullFlavor (required)
... realmCode 0..* CS
... typeId 0..1 II
.... @nullFlavor 0..1 cs Binding: CDANullFlavor (required)
.... @assigningAuthorityName 0..1 st
.... @displayable 0..1 bl
.... @root 1..1 oid, uuid, ruid Fixed Value: 2.16.840.1.113883.1.3
.... @extension 1..1 st
... @classCode 0..1 cs Binding: EntityClassDevice (required)
... @determinerCode 0..1 cs Binding: EntityDeterminer (required)
Fixed Value: INSTANCE
... code 0..1 CE Binding: CDAEntityCode (example)
... manufacturerModelName 0..1 SC Binding: Manufacturer Model Name Example (example)
... softwareName 0..1 SC Binding: Software Name Example (example)

doco Documentation for this format

Terminology Bindings

PathConformanceValueSet / CodeURI
Device.nullFlavorrequiredCDANullFlavor
http://hl7.org/cda/stds/core/ValueSet/CDANullFlavor
from this IG
Device.typeId.nullFlavorrequiredCDANullFlavor
http://hl7.org/cda/stds/core/ValueSet/CDANullFlavor
from this IG
Device.classCoderequiredEntityClassDevice
http://terminology.hl7.org/ValueSet/v3-EntityClassDevice
Device.determinerCoderequiredFixed Value: INSTANCE
http://terminology.hl7.org/ValueSet/v3-EntityDeterminer
Device.codeexampleCDAEntityCode
http://hl7.org/cda/stds/core/ValueSet/CDAEntityCode
from this IG
Device.manufacturerModelNameexampleManufacturerModelNameExample
http://terminology.hl7.org/ValueSet/v3-ManufacturerModelNameExample
Device.softwareNameexampleSoftwareNameExample
http://terminology.hl7.org/ValueSet/v3-SoftwareNameExample

This structure is derived from InfrastructureRoot

Summary

Fixed: 1 element

Structures

This structure refers to these other structures:

 

Other representations of profile: CSV, Excel