FHIR CI-Build

This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions icon

Orders and Observations icon Work GroupMaturity Level: N/A  DraftSecurity Category: Business Compartments: Device, Patient, Practitioner

Search parameters for the Resource DeviceAssociation - Search Parameters resource. Also check the Extensions registry for search parameters on extensions related to this resource.

The common parameters also apply. See Searching for more information about searching in REST, messaging, and services.


http://hl7.org/fhir/SearchParameter/DeviceAssociation-device

Parameter device:reference

Search for products that match this code

ResourceDeviceAssociation
ExpressionDeviceAssociation.device
Processing ModeNormal
Target ResourcesDevice
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceAssociation-identifier

Parameter identifier:token

The identifier of the device association

ResourceDeviceAssociation
ExpressionDeviceAssociation.identifier
Processing ModeNormal
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceAssociation-operator

Parameter operator:reference

The identity of a operator for whom to list associations

ResourceDeviceAssociation
ExpressionDeviceAssociation.operation.operator
Processing ModeNormal
Target ResourcesRelatedPerson, Practitioner, Patient
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceAssociation-patient

Parameter patient:reference

The identity of a patient for whom to list associations

ResourceDeviceAssociation
ExpressionDeviceAssociation.subject.where(resolve() is Patient)
Processing ModeNormal
Target ResourcesPatient
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceAssociation-status

Parameter status:token

The status of the device associations

ResourceDeviceAssociation
ExpressionDeviceAssociation.status
Processing ModeNormal
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceAssociation-subject

Parameter subject:reference

The identity of a patient for whom to list associations

ResourceDeviceAssociation
ExpressionDeviceAssociation.subject.where(resolve() is Patient)
Processing ModeNormal
Target ResourcesPatient
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true