This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions 
http://hl7.org/fhir/SearchParameter/ImagingStudy-based-on |
10.5.14 based-on Parameter based-on:reference
The order for the image such as Accession Number
| Resource | ImagingStudy |
| Expression |
ImagingStudy.basedOn |
| Processing Mode |
Normal |
| Target Resources |
Appointment, ServiceRequest, CarePlan, Task |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/ImagingStudy-body-site |
10.5.15 body-site Parameter body-site:token
The body site code studied
| Resource | ImagingStudy |
| Expression |
ImagingStudy.series.bodySite.concept |
| Processing Mode |
Normal |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/ImagingStudy-body-structure |
10.5.16 body-structure Parameter body-structure:reference
The body structure resource associated with the ImagingStudy
| Resource | ImagingStudy |
| Expression |
ImagingStudy.series.bodySite.reference |
| Processing Mode |
Normal |
| Target Resources |
BodyStructure |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/ImagingStudy-dicom-class |
10.5.17 dicom-class Parameter dicom-class:uri
| Resource | ImagingStudy |
| Expression |
ImagingStudy.series.instance.sopClass |
| Processing Mode |
Normal |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/clinical-encounter |
| This search parameter is part of the common search parameter clinical-encounter |
10.5.18 encounter TU Parameter encounter:reference
| Resource | ImagingStudy |
| Expression |
ImagingStudy.encounter |
| Processing Mode |
Normal |
| Target Resources |
Encounter |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/ImagingStudy-endpoint |
10.5.19 endpoint Parameter endpoint:reference
The endpoint for the study or series
| Resource | ImagingStudy |
| Expression |
ImagingStudy.endpoint | ImagingStudy.series.endpoint |
| Processing Mode |
Normal |
| Target Resources |
Endpoint |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/clinical-identifier |
| This search parameter is part of the common search parameter clinical-identifier |
10.5.20 identifier TU Parameter identifier:token
ImagingStudy: Identifiers for the Study, such as DICOM Study Instance UID
| Resource | ImagingStudy |
| Expression |
ImagingStudy.identifier |
| Processing Mode |
Normal |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/ImagingStudy-instance |
10.5.21 instance Parameter instance:token
SOP Instance UID for an instance
| Resource | ImagingStudy |
| Expression |
ImagingStudy.series.instance.uid |
| Processing Mode |
Normal |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/ImagingStudy-modality |
10.5.22 modality Parameter modality:token
The modality of the series
| Resource | ImagingStudy |
| Expression |
ImagingStudy.series.modality |
| Processing Mode |
Normal |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/clinical-patient |
| This search parameter is part of the common search parameter clinical-patient |
10.5.23 patient TU Parameter patient:reference
| Resource | ImagingStudy |
| Expression |
ImagingStudy.subject.where(resolve() is Patient) |
| Processing Mode |
Normal |
| Target Resources |
Patient |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/ImagingStudy-performer |
10.5.24 performer Parameter performer:reference
The person who performed the study
|
| |
http://hl7.org/fhir/SearchParameter/ImagingStudy-procedure |
10.5.25 procedure Parameter procedure:reference
The performed procedure for the study
| Resource | ImagingStudy |
| Expression |
ImagingStudy.procedure |
| Processing Mode |
Normal |
| Target Resources |
Procedure |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/ImagingStudy-reason-concept |
10.5.26 reason-concept D Parameter reason-concept:token
The reason code for the study
| Resource | ImagingStudy |
| Expression |
ImagingStudy.reason.concept |
| Processing Mode |
Normal |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/ImagingStudy-reason-reference |
10.5.27 reason-reference D Parameter reason-reference:reference
The resource reference describing the reason for the study
| Resource | ImagingStudy |
| Expression |
ImagingStudy.reason.reference |
| Processing Mode |
Normal |
| Target Resources |
DocumentReference, Observation, DiagnosticReport, Condition |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/ImagingStudy-referrer |
10.5.28 referrer Parameter referrer:reference
| Resource | ImagingStudy |
| Expression |
ImagingStudy.referrer |
| Processing Mode |
Normal |
| Target Resources |
PractitionerRole, Practitioner |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/ImagingStudy-series |
10.5.29 series Parameter series:token
DICOM Series Instance UID for a series
| Resource | ImagingStudy |
| Expression |
ImagingStudy.series.uid |
| Processing Mode |
Normal |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/ImagingStudy-started |
10.5.30 started Parameter started:date
When the study was started
| Resource | ImagingStudy |
| Expression |
ImagingStudy.started |
| Processing Mode |
Normal |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
| Comparators |
Allowed: eq, ne, gt, ge, lt, le, sa, eb, ap |
|
| |
http://hl7.org/fhir/SearchParameter/ImagingStudy-status |
10.5.31 status Parameter status:token
| Resource | ImagingStudy |
| Expression |
ImagingStudy.status |
| Processing Mode |
Normal |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/ImagingStudy-subject |
10.5.32 subject Parameter subject:reference
| Resource | ImagingStudy |
| Expression |
ImagingStudy.subject |
| Processing Mode |
Normal |
| Target Resources |
Device, Group, Patient |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |