openEHR to FHIR Data Type Mapping
0.1.0 - ci-build International flag

openEHR to FHIR Data Type Mapping, published by HL7 International / FHIR Infrastructure. This guide is not an authorized publication; it is the continuous build for version 0.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/openehr-fhir/data-type-mapping-ig/ and changes regularly. See the Directory of published versions

Reference Implementation

Page standards status: Informative

Reference implementation

Every fidelity claim in this guide is backed by runnable code. The separate reference implementation repository holds a TypeScript mapping ledger and a set of reference converters, together with the tests that substantiate what the mapping tables assert. Their source is maintained independently of this guide's committed publication inputs.

Why it exists

A mapping table that says lossless is an assertion. A mapping table generated from a ledger whose lossless rows must round-trip a paired instance unchanged — and whose lossy rows must drop exactly what they claim to drop, no more and no less — is a checked statement.

That is the whole point of the reference implementation. It is not a product.

Try it in your browser

The same converters and the same ledger this page describes also run as a hosted single page:

Four things are worth knowing before you paste anything into it:

  • It runs the RI's converters and ledger, not a separate re-implementation. Its build may use a different RI revision from the one behind a particular guide snapshot; agreement is not automatic across revisions.
  • Everything you paste stays in your browser. There is no backend, no telemetry, and no network call after the page loads.
  • Its displayed provenance names the guide version and the independent RI source commit. See the browser-converter documentation for the separate compatible-guide revision, which is not displayed in that provenance. A matching guide version alone does not establish revision parity with a guide snapshot.
  • The RI build's worked examples load into it as starting points, so you can edit a real instance rather than inventing one. They correspond to the examples published from that RI revision, not necessarily every guide version.

When a conversion leaves something behind, each dropped field links back to the mapping row that declares the loss.

What it is not

  • Not a published package. It is not on npm. Its source revision is independent of the guide's version and revision.
  • Not a CLI, and not a service. The hosted converter above is neither: it is a static page that runs in your own browser, with nothing behind it — read this bullet and Try it in your browser together.
  • Not a FHIR or openEHR type library. It models only the fields the mappings actually touch.
  • Not part of the IG build. Neither SUSHI nor the IG Publisher reads it.

How the guide relates to it

The mapping tables on the category pages are generated from the external RI's ledger and committed in sentinel-delimited managed regions in the guide's markdown source. The worked examples are the test fixtures the converters are exercised against at the corresponding RI revision. These committed tables and examples are not automatically synchronized with the RI's current source or the hosted converter.

The tables on Gaps and Open Items are not generated: they are maintained by hand in this guide, and the RI neither renders nor checks their content. Page-wide presentation and link checks still apply. Conventions says how editors keep them in step.

Generated regions remain owned by the RI's ledger and renderer, not by hand edits in this repository. The RI's documented authoring and compatibility process includes rendering and drift checking; an updated guide is reviewed separately. Every guide region has an external renderer definition, and every renderer output has a guide home. Publishing the committed guide needs no RI checkout and runs none of those implementation checks.

The converter contract

Every converter returns a result carrying three things: the value it produced, the fidelity it actually achieved, and one issue per piece of information it could not carry across, each naming the path it came from. A converter does not throw for a mapping-level problem — an unmappable field is data, not an exception.

The issue paths are the join between the code and the ledger. A converter that drops a field the ledger does not list, or fails to drop one it does, fails the test suite.

A converter never invents a value for an attribute the target standard declares mandatory. Where the source has nothing to fill one — a FHIR Quantity carrying only a comparator, a Coding with no code, an Attachment with no contentType — the converter returns unmapped, produces no value at all, and names the absent source path. Substituting a zero, an empty string, or a default code and reporting lossless would publish an instance that claims to be a valid DV_QUANTITY, CODE_PHRASE, or DV_MULTIMEDIA while carrying a value nobody sent. The rule and its two recorded exceptions are stated in full under the mandatory-attribute rule, and the external RI's reference/test/contract.test.ts holds every converter to it.

A converter that composes another carries the inner result's issues forward, so a declared drop cannot vanish behind a composition boundary. The same test file pins that in both directions.

Wire format

The openEHR side uses the canonical openEHR JSON form, with the _type discriminator naming the Reference Model class. The FHIR side uses ordinary FHIR JSON — including the places where that is not the obvious JavaScript value: integer64 is serialised as a JSON String, because FHIR R5 says so "due to issues with precision in floating point libraries", and this implementation publishes the format R5 has rather than the one that would be convenient.

One limitation of this code, which is not a mapping fact. The openEHR side of a numeric primitive is a JSON number, and a JavaScript number represents integers exactly only up to ±(253 − 1). A FHIR integer64 beyond that range is read as the nearest representable value. Nothing in either standard makes that a loss — Integer64 and integer64 have the same range — so it is stated here rather than published as a ledger row.

A caveat on citations

Citations to the FHIR extension pack cannot be verified against a local mirror of the R5 specification, because that mirror contains no extension definitions. Those citations are taken on the working group's authority, and are marked as such. Citations to openEHR RM pages and to FHIR R5 core pages are held to two separate rules. A citation sitting on a real endpoint SHALL name an anchor rather than a bare page, with one written-down exception where the specification offers no anchor at all. For the generated mapping tables that rule is part of the external RI ledger's structural validation; the hand-maintained tables on Gaps — where that one exception is stated — and Open Items are held to it by review. Resolving those anchors against local copies of both specifications is a second, mirror-dependent check in the RI's release gate, and it skips when the mirrors are not configured. The RI's documentation owns execution of both checks; neither runs automatically when the guide is published.

The commands

Implementation commands run in the separate RI checkout, not in this guide repository. Its maintained documentation supplies setup, invocation, and release requirements:

Citation resolution needs local mirrors of both specifications: every spec-local citation is resolved to a real anchor on a real page, not merely to a file. The separate vocabulary check needs the openEHR mirror alone. It resolves the openEHR vocabulary literals the converters write and the fixtures carry — code-set identifiers, DV_TEXT.formatting values, and the ISO 8601 lexical forms the guide flags as openEHR-accepted — against the published openEHR specification. Missing mirrors cause those tests to skip rather than prove their claims; the external RI documentation defines the configured, zero-skipped release gate. Guide publication consumes committed inputs and does not execute these suites or require their mirrors.

What the tests actually prove

  • A lossless row round-trips: the value at that row's path survives conversion out and back unchanged, and the converter reports no issue at that path.
  • A lossy row neither over-claims nor under-claims: every issue the converter reports is one the ledger declared for that direction, and the union of reported issues across all of a mapping's fixtures equals the declared set exactly.
  • An unmapped row reports its source path and produces no value at its target.
  • A converter never invents a mandatory attribute it has no source for, and a composing converter carries its inner converter's issues forward.
  • A mapping that claims something can be carried has a converter and a fixture; a mapping that claims nothing can be has neither.

Two scoping rules are deliberate, and both are narrower than they were. Rows at archetype scope are outside the matrix, because their FHIR home is a resource element and a data-type converter never sees a resource — and a row that claims that exemption while targeting an ordinary data-type element is now rejected, so the exempt set cannot grow by inattention. And a row whose source side has no counterpart in the direction under test is skipped, because there is nothing to convert from; its target side is not skipped, and a conversion that produces nothing at all has to name a path the ledger declares unmapped.