| error | There is no jira specification file defined with the expected name of FHIR-openehr-data-type-mapping in the xml folder of the https://github.com/HL7/Jira-Spec-Artifacts project. This must exist before ballot or publication. |
| en/conventions.html | information | The html source contains the word 'SHALL' but it is not in a text phrase marked as a conformance clause: 'A mapping marked lossless SHALL round-trip: converting openEHR to FHIR and back SHALL yield an equivalent instance. A mapping marked lossy SHALL document exactly which information is dropped.' CONFORMANCE_STATEMENT_WORD |
| en/cross-cutting.html | information | The html source contains the word 'SHALL' but it is not in a text phrase marked as a conformance clause: 'The rule is therefore one-directional and settled: the sender converts. Non-UTF-8 content SHALL be converted to UTF-8 before mapping, and the original encoding is not preserved on the FHIR side. DV_TEXT.encoding is unmapped for this reason, and the row says so. Where a charset applies to attached binary content rather than to text — DV_MULTIMEDIA.charset — it is carried as the MIME type's charset parameter, which R5's contentType includes — see Other Data.' CONFORMANCE_STATEMENT_WORD |
| output/en/cross-cutting.html (l279/c2) | error | The page skips a heading level: <h4> 'Cross-cutting concerns' (id=cross-cutting-concerns) follows <h2> 'Cross-Cutting Concerns', so it should be <h3>. Heading levels must not skip a level going down (WCAG compliance test) HTML_HEADING_LEVEL_SKIPPED |
| en/downloads.html#/html/body/div/div/div/div/div/ul/li/a at Line 287, column 8 | error | The link 'package.tgz' for "package.tgz" cannot be resolved HTML_LINK_CHECK_FAILED |
| en/downloads.html#/html/body/div/div/div/div/div/ul/li/a at Line 296, column 8 | error | The link 'definitions.xml.zip' for "XML" cannot be resolved HTML_LINK_CHECK_FAILED |
| en/downloads.html#/html/body/div/div/div/div/div/ul/li/a at Line 297, column 8 | error | The link 'definitions.json.zip' for "JSON" cannot be resolved HTML_LINK_CHECK_FAILED |
| en/downloads.html#/html/body/div/div/div/div/div/ul/li/a at Line 298, column 8 | error | The link 'definitions.ttl.zip' for "TTL" cannot be resolved HTML_LINK_CHECK_FAILED |
| en/downloads.html#/html/body/div/div/div/div/div/ul/li/a at Line 307, column 8 | error | The link 'examples.xml.zip' for "XML" cannot be resolved HTML_LINK_CHECK_FAILED |
| en/downloads.html#/html/body/div/div/div/div/div/ul/li/a at Line 308, column 8 | error | The link 'examples.json.zip' for "JSON" cannot be resolved HTML_LINK_CHECK_FAILED |
| en/downloads.html#/html/body/div/div/div/div/div/ul/li/a at Line 309, column 8 | error | The link 'examples.ttl.zip' for "TTL" cannot be resolved HTML_LINK_CHECK_FAILED |
| en/gaps.html | information | The html source contains the word 'SHOULD' but it is not in a text phrase marked as a conformance clause: 'An approximate magnitude cannot be carried in an R5 Quantity. FHIR-56000 adds ~ in the published R6 drafts, which recommend reading it as within 10% of the stated value while allowing other values, and say systems SHOULD state more with the quantity-confidenceInterval extension; it is not applied in R5.' CONFORMANCE_STATEMENT_WORD |
| en/ig_changelog.html | information | The html source contains the word 'SHALL' but it is not in a text phrase marked as a conformance clause: 'mapping.html became the index to the category pages. Its conventions section moved to conventions.html, and the two normative SHALL sentences moved verbatim — "A mapping marked lossless SHALL round-trip: converting openEHR to FHIR and back SHALL yield an equivalent instance. A mapping marked lossy SHALL document exactly which information is dropped." That is a relocation, not a rewording; no conformance language changed.' CONFORMANCE_STATEMENT_WORD |
| en/ig_changelog.html | information | No conformance term found in the text: 6.2.8 lists
DV_QUANTITY's declared attributes as magnitude, precision, units,
units_system and units_display_name, and magnitude_status is declared on
CONFORMANCE_STATEMENT_NOCONFWORD |
| en/ig_changelog.html | information | The html source contains the word 'SHALL' but it is not in a text phrase marked as a conformance clause: 'Temporal data — DV_DATE, DV_TIME, DV_DATE_TIME, and DV_DURATION, with the ISO 8601 subset differences stated as mapping rules: compact openEHR forms SHALL be expanded, partial precision SHALL be truncated rather than padded, fractional seconds truncate from nine digits to three, and a time carries its offset in the timezone extension because FHIR time cannot.' CONFORMANCE_STATEMENT_WORD |
| en/ig_changelog.html | information | The html source contains the word 'SHALL' but it is not in a text phrase marked as a conformance clause: 'openEHR's compact time is published as openEHR writes it, and the hour-only forms are published at all. The ISO 8601 subset table carried T143000, T1430 and T143000+0100 as forms openEHR accepts, under a SHALL. valid_iso8601_time puts no T designator on a standalone time — T separates the date from the time in valid_iso8601_date_time and nowhere else — so the three forms openEHR does publish, 143000, 1430 and 143000+0100, had no row, no rule and no test, and a conformant 143000 was read as the year-and-month 1430-00 and published as a FHIR time at lossless. The three rows are retitled to the forms openEHR publishes, the compact ±hh offset gains a row of its own, and the expansion helper now takes the temporal kind explicitly rather than guessing from digit count — 143000 and 202603 are the same six digits, and no lexical rule can tell them apart. The hour-only partial forms hh, YYYY-MM-DDThh and YYYYMMDDThh, which valid_iso8601_time and valid_iso8601_date_time both publish, are new rows with new drops: DV_TIME.value[hour-precision] and DV_DATE_TIME.value[hour-precision], each naming the two levels of precision the FHIR value claims that the source did not state.' CONFORMANCE_STATEMENT_WORD |
| en/ig_changelog.html | information | The html source contains the word 'SHOULD' but it is not in a text phrase marked as a conformance clause: 'formatting: html is not a Reference Model value, so the guide stops publishing one. The type model declared html among "the formatting values the Reference Model defines", the converter wrote it at lossless, and the guide published a SHOULD recommending a rendering-xhtml target — in the same note that admitted XHTML support was pending a Reference Model change request. RM § 5.1.7 enumerates DV_TEXT.formatting exhaustively — Void, "markdown", "plain", "plain_no_newlines", and a legacy deprecated CSS string — and rejects HTML as a formatting approach explicitly. html is removed from the enumeration, nothing emits rendering-xhtml, and the recommendation is withdrawn rather than softened. What remains is stated as what it is: a FHIR feature openEHR has no counterpart for, published as its own row with both citations and a fidelity verdict in each direction, and in the FHIR-features gap inventory, pending the change request. A received string carrying the extension still converts — the text is carried and the rendering instruction is a named drop — so nothing that maps faithfully is refused.' CONFORMANCE_STATEMENT_WORD |
| en/ig_changelog.html | information | The html source contains the word 'SHALL NOT' but it is not in a text phrase marked as a conformance clause: 'TERM_MAPPING.match is the Reference Model's "unknown", and it is reported. TERM_MAPPING ↔ Coding minted match: '=' — "(supposedly) equivalent", the strongest assertion the attribute can carry — from a Coding that states no degree of equivalence at all, and reported lossless. The same module declares, forty lines away and in the opposite direction, that Coding has no element expressing equivalence. RM § 5.2.2 enumerates the match results and ships a designated value for exactly this case: ?, "the kind of mapping is unknown". That value is now written and reported, so the conversion is lossy and asserts nothing about the two terms; the second site that built a TERM_MAPPING inline is gone, replaced by a call to the one converter, so the two cannot diverge. The published closed list of permitted substitutions grows from two to three, deliberately, and the SHALL NOT above it is unchanged — the behaviour was made to obey the verb rather than the verb softened. The list and the substituting sites in code are now asserted to be the same set, so neither can grow without the other.' CONFORMANCE_STATEMENT_WORD |
| en/ig_changelog.html | information | The html source contains the word 'SHALL NOT' but it is not in a text phrase marked as a conformance clause: 'Which coding is a DV_CODED_TEXT's defining code is now declared as carried only by order. R5 says the "ordering of codings is undefined and SHALL NOT be used to infer meaning". mapping-coded.html: a new DV_CODED_TEXT.defining_code[with-mappings] sub-case, open, is lossy both ways. Outbound, once mappings add codings, the defining code is marked only by coming first, because userSelected would claim that a user chose it. Inbound, where not exactly one coding is marked userSelected, the first coding is taken and the choice is reported. The "Choosing the defining code" prose says the same. mapping-other.html: DV_STATE.value now declares the drops it inherits from DV_CODED_TEXT ↔ CodeableConcept in both directions, including the mapping drops it had left undeclared outbound, so it is lossy outbound rather than lossless. gaps.html lists the new lossy rows in its generated summaries. open-items.html: HTA-170 is recorded as mis-filed, because coding-purpose is FHIR-I's code system in the Extensions Registry, and this guide now recommends keeping it rather than withdrawing it. ' CONFORMANCE_STATEMENT_WORD |
| en/ig_changelog.html | information | The html source contains the word 'SHOULD' but it is not in a text phrase marked as a conformance clause: ' FHIR-56000 is recorded as applied in R6. open-items.html: ~ Approximately is in the published R6 drafts 6.0.0-ballot5 and 6.0.0-snapshot1, so the item is no longer "not applied". mapping-quantity.html and mapping-temporal.html, and their rows on gaps.html: the magnitude_status[~] rows now quote R6's own guidance — a recommended, not default, 10% approximation, and a SHOULD to use the quantity-confidenceInterval extension — and say why that extension, though published for R5, is not used to carry ~: it needs a confidence level and interval bounds that ~ does not state. No verdict changed; both rows stay unmapped in R5. ' CONFORMANCE_STATEMENT_WORD |
| en/mapping-coded.html | information | The html source contains the word 'MAY' but it is not in a text phrase marked as a conformance clause: 'MAY add a system when the scope of the issuer is understood and the system is unique in that context — for example http://example.org/facility/1111-1111-111-11/local-procedure-codes;' CONFORMANCE_STATEMENT_WORD |
| en/mapping-other.html | information | The html source contains the word 'SHALL NOT' but it is not in a text phrase marked as a conformance clause: '→ FHIR: drops DV_CODED_TEXT.mappings.match — the degree of equivalence has no element on Coding — this conversion delegates to DV_CODED_TEXT ↔ CodeableConcept and carries its drops forward; DV_CODED_TEXT.mappings.purpose — no representation has been chosen for TERM_MAPPING.purpose, so the delegated conversion emits nothing for it; DV_CODED_TEXT.defining_code[with-mappings] — once a mapping adds a second coding, only the order of the codings marks the state’s defining code, and R5 says that order SHALL NOT be used to infer meaning → openEHR: drops Coding.version — openEHR has no separate version field and no format for combining system and version into terminology_id has been chosen, so the version is not carried — this conversion delegates to DV_CODED_TEXT ↔ CodeableConcept, and through it to CODE_PHRASE ↔ Coding, and carries both mappings’ drops forward; CodeableConcept.coding.userSelected — openEHR has no field marking which coding a user chose; the flag is consumed to select the inner defining_code and is not carried any further; CodeableConcept.coding[unmarked] — several codings arrive and not exactly one is marked userSelected, so the state’s defining code is chosen by position, which R5 says SHALL NOT be done; TERM_MAPPING.match — each further coding becomes a TERM_MAPPING whose mandatory match a Coding cannot source, so the Reference Model’s ? is written and reported The state name maps as an ordinary DV_CODED_TEXT; see Coded Data. What does not map is the state machine it belongs to. A code from openEHR’s own terminology currently reaches Coding.system as the bare openehr, which R5 does not accept as a system; the published openEHR FHIR CodeSystems are recorded on Open Items as the answer. The openEHR attribute is mandatory and the FHIR element is optional, so an incoming instance that omits it cannot be converted: the reference implementation produces nothing rather than inventing a value. See the mandatory-attribute rule.' CONFORMANCE_STATEMENT_WORD |
| en/mapping-quantity.html | information | The html source contains the word 'SHOULD' but it is not in a text phrase marked as a conformance clause: 'Precision is carried differently on each side. openEHR uses precision together with the lexical form of magnitude; FHIR uses the lexical form of decimal together with the quantity-precision extension. A mapping SHOULD take the most granular precision available across both fields. openEHR precision = -1 (unlimited) corresponds to the absence of the extension.' CONFORMANCE_STATEMENT_WORD |
| en/mapping-reference.html | information | The html source contains the word 'SHOULD NOT' but it is not in a text phrase marked as a conformance clause: '→ openEHR: No LINK is produced at all, so nothing lands in target. LINK.type is mandatory and a plain Reference has no field that can source it — see the LINK.type row — so the reference travels only as part of a LINK that cannot be built. (owner: openehr-modelling) R5 defines Reference.reference as "a location at which the other resource is found", and an ehr: URI names an item in an openEHR EHR rather than a FHIR resource, and does not resolve. Reference.identifier is the element R5 provides for a target that "is not available through a FHIR server", and a URI that is itself the identifier takes the system urn:ietf:rfc:3986. Resolving the target to a FHIR resource takes knowledge of how the record was converted, which a data type does not have. Where the target is a sub-element, two standard extensions cover the granularity: targetElement, carrying a target Element.id, and targetPath, carrying a restricted FHIRPath expression. Prefer targetElement where you control the target instance and can guarantee an Element.id; use targetPath where you cannot. A mapping into FHIR SHOULD NOT produce either unless the source data genuinely needs sub-element granularity, because most consumers do not interpret them.' CONFORMANCE_STATEMENT_WORD |
| en/mapping-temporal.html | information | The html source contains the word 'SHALL' but it is not in a text phrase marked as a conformance clause: 'The two ISO 8601 subsets are not the same subset. openEHR permits compact forms — 20250301, T143000 — while FHIR requires the extended form — 2025-03-01, 14:30:00. Compact values SHALL be expanded before mapping to FHIR. The precise comparison is published as a machine-generated table on Cross-Cutting Concerns, rendered directly from the code that implements the conversion, so the guide and the reference implementation cannot disagree about it.' CONFORMANCE_STATEMENT_WORD |
| en/mapping-textual.html | information | The html source contains the word 'SHOULD' but it is not in a text phrase marked as a conformance clause: '→ FHIR: drops DV_TEXT.formatting — markdown is carried, by the rendering-markdown extension or by choosing a markdown target. What is dropped is the distinction between plain and plain_no_newlines — FHIR has no element recording it — and the legacy deprecated CSS string, which has no FHIR representation either Where formatting is markdown, the FHIR target SHOULD be a markdown element, or a string carrying the rendering-markdown extension, and a FHIR string carrying that extension on the way back sets formatting to markdown. There is no html formatting value. RM § 5.1.7 enumerates formatting exhaustively — Void, "markdown", "plain", "plain_no_newlines", and a legacy deprecated CSS string — and rejects HTML as a formatting approach explicitly, so this guide recommends no XHTML target and emits none. XHTML support on the openEHR side is pending a Reference Model change request; until it lands the guide publishes it as a gap, on the row below and in the FHIR features with no openEHR counterpart inventory.' CONFORMANCE_STATEMENT_WORD |
| en/open-items.html | information | The html source contains the word 'SHALL' but it is not in a text phrase marked as a conformance clause: 'FHIR: Checked against R5 Attachment (hash is SHA-1; contentType "includes mime type parameters such as charset"; url "SHALL resolve to actual data"; att-1), the published alternate-hash extension and its integrity-check-algorithms code system, which holds exactly openEHR’s seven algorithms. The reference converter had written a SHA-256 hash into hash, dropped charset rather than folding it, and passed a plain-text URI through; a non-SHA-1 hash now travels in alternate-hash, charset in the MIME parameter, and the URI is percent-encoded.' CONFORMANCE_STATEMENT_WORD |
| en/reference-implementation.html | information | The html source contains the word 'SHALL' but it is not in a text phrase marked as a conformance clause: 'Citations to the FHIR extension pack cannot be verified against a local mirror of the R5 specification, because that mirror contains no extension definitions. Those citations are taken on the working group's authority, and are marked as such. Citations to openEHR RM pages and to FHIR R5 core pages are held to two separate rules. A citation sitting on a real endpoint SHALL name an anchor rather than a bare page, with one written-down exception where the specification offers no anchor at all. For the generated mapping tables that rule is part of the external RI ledger's structural validation; the hand-maintained tables on Gaps — where that one exception is stated — and Open Items are held to it by review. Resolving those anchors against local copies of both specifications is a second, mirror-dependent check in the RI's release gate, and it skips when the mirrors are not configured. The RI's documentation owns execution of both checks; neither runs automatically when the guide is published.' CONFORMANCE_STATEMENT_WORD |
| 1 | warning | The HTML fragment 'ip-statements.xhtml' is not included anywhere in the produced implementation guide |
| 3 | warning | An HTML fragment from the set [dependency-table.xhtml, dependency-table-short.xhtml, dependency-table-nontech.xhtml] is not included anywhere in the produced implementation guide |
| Path | Severity | Message | Validating |
| ImplementationGuide.jurisdiction[0] (l1/c2337) | information | Reference to deprecated ValueSet http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0 (from https://tx.fhir.org/r5, see log, or see the servers logic) MSG_DEPRECATED0ms tx-op
0ms http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0: Analysing http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0 for validation purposes
0ms http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0: Parameters: disp-lang=en, generate-narrative, default-to-latest
0ms http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0: Prepare include[0]: "(urn:iso:std:iso:3166)"
1ms http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0: CodeSystem found: "urn:iso:std:iso:3166|2018"
1ms http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0: Prepare include[1]: "(urn:iso:std:iso:3166:-2)"
1ms http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0: CodeSystem found: "urn:iso:std:iso:3166:-2|2021"
1ms http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0: Prepare include[2]: "(http://unstats.un.org/unsd/methods/m49/m49.htm)(class=region)"
1ms http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0: CodeSystem found: "http://unstats.un.org/unsd/methods/m49/m49.htm|null"
1ms http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0: Validate "[http://unstats.un.org/unsd/methods/m49/m49.htm#001 ("World")]"
1ms http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0: Check "http://unstats.un.org/unsd/methods/m49/m49.htm#001"
1ms http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0: Include for urn:iso:std:iso:3166 not considered for "http://unstats.un.org/unsd/methods/m49/m49.htm"
1ms http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0: Include for urn:iso:std:iso:3166:-2 not considered for "http://unstats.un.org/unsd/methods/m49/m49.htm"
1ms http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0: CodeSystem found: http://unstats.un.org/unsd/methods/m49/m49.htm|null for http://unstats.un.org/unsd/methods/m49/m49.htm
1ms http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0: check code in (http://unstats.un.org/unsd/methods/m49/m49.htm)(class=region) at CodeableConcept.coding[0]
1ms http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0: Filter class = region: Code "001" found in http://unstats.un.org/unsd/methods/m49/m49.htm|null | ImplementationGuide |
| ImplementationGuide.definition.parameter[9].code (l1/c8955) | information | Reference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTAL | ImplementationGuide |
| ImplementationGuide.definition.parameter[10].code (l1/c9070) | information | Reference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTAL | ImplementationGuide |
| ImplementationGuide.definition.parameter[11].code (l1/c9181) | information | Reference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTAL | ImplementationGuide |
| ImplementationGuide.definition.parameter[12].code (l1/c9294) | information | Reference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTAL | ImplementationGuide |
| ImplementationGuide.definition.parameter[13].code (l1/c9403) | information | Reference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTAL | ImplementationGuide |
| ImplementationGuide.definition.parameter[14].code (l1/c9516) | information | Reference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTAL | ImplementationGuide |
| ImplementationGuide.definition.parameter[15].code (l1/c9627) | information | Reference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTAL | ImplementationGuide |
| ImplementationGuide.definition.parameter[16].code (l1/c9739) | information | Reference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTAL | ImplementationGuide |
| ImplementationGuide.definition.parameter[17].code (l1/c9852) | information | Reference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTAL | ImplementationGuide |
| ImplementationGuide.definition.parameter[18].code (l1/c9959) | information | Reference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTAL | ImplementationGuide |
| ImplementationGuide.definition.parameter[19].code (l1/c10069) | information | Reference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTAL | ImplementationGuide |
| ImplementationGuide.definition.parameter[20].code (l1/c10179) | information | Reference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTAL | ImplementationGuide |
| ImplementationGuide.definition.parameter[21].code (l1/c10296) | information | Reference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTAL | ImplementationGuide |
| ImplementationGuide.definition.parameter[22].code (l1/c10405) | information | Reference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTAL | ImplementationGuide |
| ImplementationGuide.definition.parameter[23].code (l1/c10511) | information | Reference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTAL | ImplementationGuide |
| ImplementationGuide.definition.parameter[29].code (l1/c11207) | information | Reference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 MSG_EXPERIMENTAL | ImplementationGuide |
| ImplementationGuide (l1/c13142) | warning | HL7 Implementation Guides should state their maturity explicitly using the extension http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm IG_HL7_FMM_SHOULD | -- |
| Resource | information | The resource ImplementationGuide/hl7.fhir.uv.openehr-data-type-mapping could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/ig-guidance/oids.html) | -- |