CH EMS (R4)
2.1.0-ci-build - ci-build
CH EMS (R4), published by IVR Interverband für Rettungswesen. This guide is not an authorized publication; it is the continuous build for version 2.1.0-ci-build built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7ch/ch-ems/ and changes regularly. See the Directory of published versions
Active as of 2025-09-01 |
<ConceptMap xmlns="http://hl7.org/fhir">
<id value="EmsProcedures2Fhir"/>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: ConceptMap EmsProcedures2Fhir</b></p><a name="EmsProcedures2Fhir"> </a><a name="hcEmsProcedures2Fhir"> </a><p>Mapping from <a href="StructureDefinition-logicalmodel-ems-protocol.html">EMS Protocol</a> to <a href="StructureDefinition-ch-ems-document.html">CH EMS Document</a></p><br/><p><b>Group 1 </b>Mapping from <a href="StructureDefinition-logicalmodel-ems-protocol.html">EMS Protocol</a> to <a href="StructureDefinition-ch-ems-composition.html">CH EMS Composition</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.procedures</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Composition.section:procedures</td></tr></table><hr/><p><b>Group 2 </b>Mapping from <a href="StructureDefinition-logicalmodel-ems-protocol.html">EMS Protocol</a> to <a href="StructureDefinition-ch-ems-medicationadministration.html">CH EMS MedicationAdministration</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.medication</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>MedicationAdministration.medicationReference</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.dose</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>MedicationAdministration.dosage.dose</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.timing.time</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>MedicationAdministration.effectiveDateTime</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.timing.period</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>MedicationAdministration.effectivePeriod</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.routeOfAdministration</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>MedicationAdministration.dosage.route</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.methodOfAdministration</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>MedicationAdministration.dosage.method</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.reason</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>MedicationAdministration.reasonCode.text</td></tr></table><hr/><p><b>Group 3 </b>Mapping from <a href="StructureDefinition-logicalmodel-ems-protocol.html">EMS Protocol</a> to <a href="StructureDefinition-ch-ems-medication.html">CH EMS Medication</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.medication.product.gtin</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Medication.code.coding:GTIN</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.medication.product.atc</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Medication.code.coding:ATC</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.medication.product.freeText</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Medication.code.text</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.medication.ingredient</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Medication.ingredient.itemCodeableConcept</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.medication.galenicForm</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Medication.form</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.medication.packageSize</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Medication.amount</td></tr></table><hr/><p><b>Group 4 </b>Mapping from <a href="StructureDefinition-logicalmodel-ems-protocol.html">EMS Protocol</a> to <a href="StructureDefinition-ch-ems-procedure-woundtreatment.html">CH EMS Procedure: Wound Treatment</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.procedures.woundTreatment</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Procedure.code</td></tr></table><hr/><p><b>Group 5 </b>Mapping from <a href="StructureDefinition-logicalmodel-ems-protocol.html">EMS Protocol</a> to <a href="StructureDefinition-ch-ems-procedure-airways.html">CH EMS Procedure: Airways</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.procedures.airway.intervention</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Procedure.code</td></tr></table><hr/><p><b>Group 6 </b>Mapping from <a href="StructureDefinition-logicalmodel-ems-protocol.html">EMS Protocol</a> to <a href="StructureDefinition-ch-ems-procedure-breathing.html">CH EMS Procedure: Breathing</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.procedures.breathing.intervention</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Procedure.code</td></tr></table><hr/><p><b>Group 7 </b>Mapping from <a href="StructureDefinition-logicalmodel-ems-protocol.html">EMS Protocol</a> to <a href="StructureDefinition-ch-ems-procedure.html">CH EMS Procedure (Base)</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.procedures.circulation.intervention</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Procedure.code</td></tr></table><hr/><p><b>Group 8 </b>Mapping from <a href="StructureDefinition-logicalmodel-ems-protocol.html">EMS Protocol</a> to <a href="StructureDefinition-ch-ems-procedure.html">CH EMS Procedure (Base)</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.procedures.disability.intervention</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Procedure.code</td></tr></table><hr/><p><b>Group 9 </b>Mapping from <a href="StructureDefinition-logicalmodel-ems-protocol.html">EMS Protocol</a> to <a href="StructureDefinition-ch-ems-procedure.html">CH EMS Procedure (Base)</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.procedures.exposure.intervention</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Procedure.code</td></tr></table></div>
</text>
<url value="http://fhir.ch/ig/ch-ems/ConceptMap/EmsProcedures2Fhir"/>
<version value="2.1.0-ci-build"/>
<name value="EmsProcedures2Fhir"/>
<title value="EMS Procedures to FHIR Mapping"/>
<status value="active"/>
<experimental value="false"/>
<date value="2025-09-01T13:45:24+00:00"/>
<publisher value="IVR Interverband für Rettungswesen"/>
<contact>
<name value="IVR Interverband für Rettungswesen"/>
<telecom>
<system value="url"/>
<value value="https://www.ivr-ias.ch/"/>
</telecom>
</contact>
<description
value="This map shows how the procedures section from the EMS Protocol is represented using FHIR."/>
<jurisdiction>
<coding>
<system value="urn:iso:std:iso:3166"/>
<code value="CH"/>
</coding>
</jurisdiction>
<copyright value="CC0-1.0"/>
<sourceUri
value="http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol"/>
<targetUri
value="http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-document"/>
<group>
<source
value="http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol"/>
<target
value="http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-composition"/>
<element>
<code value="EMSProtocol.procedures"/>
<target>
<code value="Composition.section:procedures"/>
<equivalence value="equivalent"/>
</target>
</element>
</group>
<group>
<source
value="http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol"/>
<target
value="http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-medicationadministration"/>
<element>
<code
value="EMSProtocol.procedures.medicationAdministration.medication"/>
<target>
<code value="MedicationAdministration.medicationReference"/>
<equivalence value="equivalent"/>
</target>
</element>
<element>
<code value="EMSProtocol.procedures.medicationAdministration.dose"/>
<target>
<code value="MedicationAdministration.dosage.dose"/>
<equivalence value="equivalent"/>
</target>
</element>
<element>
<code
value="EMSProtocol.procedures.medicationAdministration.timing.time"/>
<target>
<code value="MedicationAdministration.effectiveDateTime"/>
<equivalence value="equivalent"/>
</target>
</element>
<element>
<code
value="EMSProtocol.procedures.medicationAdministration.timing.period"/>
<target>
<code value="MedicationAdministration.effectivePeriod"/>
<equivalence value="equivalent"/>
</target>
</element>
<element>
<code
value="EMSProtocol.procedures.medicationAdministration.routeOfAdministration"/>
<target>
<code value="MedicationAdministration.dosage.route"/>
<equivalence value="equivalent"/>
</target>
</element>
<element>
<code
value="EMSProtocol.procedures.medicationAdministration.methodOfAdministration"/>
<target>
<code value="MedicationAdministration.dosage.method"/>
<equivalence value="equivalent"/>
</target>
</element>
<element>
<code value="EMSProtocol.procedures.medicationAdministration.reason"/>
<target>
<code value="MedicationAdministration.reasonCode.text"/>
<equivalence value="equivalent"/>
</target>
</element>
</group>
<group>
<source
value="http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol"/>
<target
value="http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-medication"/>
<element>
<code
value="EMSProtocol.procedures.medicationAdministration.medication.product.gtin"/>
<target>
<code value="Medication.code.coding:GTIN"/>
<equivalence value="equivalent"/>
</target>
</element>
<element>
<code
value="EMSProtocol.procedures.medicationAdministration.medication.product.atc"/>
<target>
<code value="Medication.code.coding:ATC"/>
<equivalence value="equivalent"/>
</target>
</element>
<element>
<code
value="EMSProtocol.procedures.medicationAdministration.medication.product.freeText"/>
<target>
<code value="Medication.code.text"/>
<equivalence value="equivalent"/>
</target>
</element>
<element>
<code
value="EMSProtocol.procedures.medicationAdministration.medication.ingredient"/>
<target>
<code value="Medication.ingredient.itemCodeableConcept"/>
<equivalence value="equivalent"/>
</target>
</element>
<element>
<code
value="EMSProtocol.procedures.medicationAdministration.medication.galenicForm"/>
<target>
<code value="Medication.form"/>
<equivalence value="equivalent"/>
</target>
</element>
<element>
<code
value="EMSProtocol.procedures.medicationAdministration.medication.packageSize"/>
<target>
<code value="Medication.amount"/>
<equivalence value="equivalent"/>
</target>
</element>
</group>
<group>
<source
value="http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol"/>
<target
value="http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-procedure-woundtreatment"/>
<element>
<code value="EMSProtocol.procedures.woundTreatment"/>
<target>
<code value="Procedure.code"/>
<equivalence value="equivalent"/>
</target>
</element>
</group>
<group>
<source
value="http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol"/>
<target
value="http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-procedure-airways"/>
<element>
<code value="EMSProtocol.procedures.airway.intervention"/>
<target>
<code value="Procedure.code"/>
<equivalence value="equivalent"/>
</target>
</element>
</group>
<group>
<source
value="http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol"/>
<target
value="http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-procedure-breathing"/>
<element>
<code value="EMSProtocol.procedures.breathing.intervention"/>
<target>
<code value="Procedure.code"/>
<equivalence value="equivalent"/>
</target>
</element>
</group>
<group>
<source
value="http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol"/>
<target
value="http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-procedure"/>
<element>
<code value="EMSProtocol.procedures.circulation.intervention"/>
<target>
<code value="Procedure.code"/>
<equivalence value="equivalent"/>
</target>
</element>
</group>
<group>
<source
value="http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol"/>
<target
value="http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-procedure"/>
<element>
<code value="EMSProtocol.procedures.disability.intervention"/>
<target>
<code value="Procedure.code"/>
<equivalence value="equivalent"/>
</target>
</element>
</group>
<group>
<source
value="http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol"/>
<target
value="http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-procedure"/>
<element>
<code value="EMSProtocol.procedures.exposure.intervention"/>
<target>
<code value="Procedure.code"/>
<equivalence value="equivalent"/>
</target>
</element>
</group>
</ConceptMap>