CH EMS (R4)
2.1.0-ci-build - ci-build
CH EMS (R4), published by IVR Interverband für Rettungswesen. This guide is not an authorized publication; it is the continuous build for version 2.1.0-ci-build built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7ch/ch-ems/ and changes regularly. See the Directory of published versions
Active as of 2025-09-01 |
{
"resourceType" : "ConceptMap",
"id" : "EmsProcedures2Fhir",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: ConceptMap EmsProcedures2Fhir</b></p><a name=\"EmsProcedures2Fhir\"> </a><a name=\"hcEmsProcedures2Fhir\"> </a><p>Mapping from <a href=\"StructureDefinition-logicalmodel-ems-protocol.html\">EMS Protocol</a> to <a href=\"StructureDefinition-ch-ems-document.html\">CH EMS Document</a></p><br/><p><b>Group 1 </b>Mapping from <a href=\"StructureDefinition-logicalmodel-ems-protocol.html\">EMS Protocol</a> to <a href=\"StructureDefinition-ch-ems-composition.html\">CH EMS Composition</a></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.procedures</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>Composition.section:procedures</td></tr></table><hr/><p><b>Group 2 </b>Mapping from <a href=\"StructureDefinition-logicalmodel-ems-protocol.html\">EMS Protocol</a> to <a href=\"StructureDefinition-ch-ems-medicationadministration.html\">CH EMS MedicationAdministration</a></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.medication</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>MedicationAdministration.medicationReference</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.dose</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>MedicationAdministration.dosage.dose</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.timing.time</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>MedicationAdministration.effectiveDateTime</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.timing.period</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>MedicationAdministration.effectivePeriod</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.routeOfAdministration</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>MedicationAdministration.dosage.route</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.methodOfAdministration</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>MedicationAdministration.dosage.method</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.reason</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>MedicationAdministration.reasonCode.text</td></tr></table><hr/><p><b>Group 3 </b>Mapping from <a href=\"StructureDefinition-logicalmodel-ems-protocol.html\">EMS Protocol</a> to <a href=\"StructureDefinition-ch-ems-medication.html\">CH EMS Medication</a></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.medication.product.gtin</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>Medication.code.coding:GTIN</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.medication.product.atc</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>Medication.code.coding:ATC</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.medication.product.freeText</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>Medication.code.text</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.medication.ingredient</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>Medication.ingredient.itemCodeableConcept</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.medication.galenicForm</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>Medication.form</td></tr><tr><td>EMSProtocol.procedures.medicationAdministration.medication.packageSize</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>Medication.amount</td></tr></table><hr/><p><b>Group 4 </b>Mapping from <a href=\"StructureDefinition-logicalmodel-ems-protocol.html\">EMS Protocol</a> to <a href=\"StructureDefinition-ch-ems-procedure-woundtreatment.html\">CH EMS Procedure: Wound Treatment</a></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.procedures.woundTreatment</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>Procedure.code</td></tr></table><hr/><p><b>Group 5 </b>Mapping from <a href=\"StructureDefinition-logicalmodel-ems-protocol.html\">EMS Protocol</a> to <a href=\"StructureDefinition-ch-ems-procedure-airways.html\">CH EMS Procedure: Airways</a></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.procedures.airway.intervention</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>Procedure.code</td></tr></table><hr/><p><b>Group 6 </b>Mapping from <a href=\"StructureDefinition-logicalmodel-ems-protocol.html\">EMS Protocol</a> to <a href=\"StructureDefinition-ch-ems-procedure-breathing.html\">CH EMS Procedure: Breathing</a></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.procedures.breathing.intervention</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>Procedure.code</td></tr></table><hr/><p><b>Group 7 </b>Mapping from <a href=\"StructureDefinition-logicalmodel-ems-protocol.html\">EMS Protocol</a> to <a href=\"StructureDefinition-ch-ems-procedure.html\">CH EMS Procedure (Base)</a></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.procedures.circulation.intervention</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>Procedure.code</td></tr></table><hr/><p><b>Group 8 </b>Mapping from <a href=\"StructureDefinition-logicalmodel-ems-protocol.html\">EMS Protocol</a> to <a href=\"StructureDefinition-ch-ems-procedure.html\">CH EMS Procedure (Base)</a></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.procedures.disability.intervention</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>Procedure.code</td></tr></table><hr/><p><b>Group 9 </b>Mapping from <a href=\"StructureDefinition-logicalmodel-ems-protocol.html\">EMS Protocol</a> to <a href=\"StructureDefinition-ch-ems-procedure.html\">CH EMS Procedure (Base)</a></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.procedures.exposure.intervention</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>Procedure.code</td></tr></table></div>"
},
"url" : "http://fhir.ch/ig/ch-ems/ConceptMap/EmsProcedures2Fhir",
"version" : "2.1.0-ci-build",
"name" : "EmsProcedures2Fhir",
"title" : "EMS Procedures to FHIR Mapping",
"status" : "active",
"experimental" : false,
"date" : "2025-09-01T13:45:24+00:00",
"publisher" : "IVR Interverband für Rettungswesen",
"contact" : [
{
"name" : "IVR Interverband für Rettungswesen",
"telecom" : [
{
"system" : "url",
"value" : "https://www.ivr-ias.ch/"
}
]
}
],
"description" : "This map shows how the procedures section from the EMS Protocol is represented using FHIR.",
"jurisdiction" : [
{
"coding" : [
{
"system" : "urn:iso:std:iso:3166",
"code" : "CH"
}
]
}
],
"copyright" : "CC0-1.0",
"sourceUri" : "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
"targetUri" : "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-document",
"group" : [
{
"source" : "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
"target" : "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-composition",
"element" : [
{
"code" : "EMSProtocol.procedures",
"target" : [
{
"code" : "Composition.section:procedures",
"equivalence" : "equivalent"
}
]
}
]
},
{
"source" : "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
"target" : "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-medicationadministration",
"element" : [
{
"code" : "EMSProtocol.procedures.medicationAdministration.medication",
"target" : [
{
"code" : "MedicationAdministration.medicationReference",
"equivalence" : "equivalent"
}
]
},
{
"code" : "EMSProtocol.procedures.medicationAdministration.dose",
"target" : [
{
"code" : "MedicationAdministration.dosage.dose",
"equivalence" : "equivalent"
}
]
},
{
"code" : "EMSProtocol.procedures.medicationAdministration.timing.time",
"target" : [
{
"code" : "MedicationAdministration.effectiveDateTime",
"equivalence" : "equivalent"
}
]
},
{
"code" : "EMSProtocol.procedures.medicationAdministration.timing.period",
"target" : [
{
"code" : "MedicationAdministration.effectivePeriod",
"equivalence" : "equivalent"
}
]
},
{
"code" : "EMSProtocol.procedures.medicationAdministration.routeOfAdministration",
"target" : [
{
"code" : "MedicationAdministration.dosage.route",
"equivalence" : "equivalent"
}
]
},
{
"code" : "EMSProtocol.procedures.medicationAdministration.methodOfAdministration",
"target" : [
{
"code" : "MedicationAdministration.dosage.method",
"equivalence" : "equivalent"
}
]
},
{
"code" : "EMSProtocol.procedures.medicationAdministration.reason",
"target" : [
{
"code" : "MedicationAdministration.reasonCode.text",
"equivalence" : "equivalent"
}
]
}
]
},
{
"source" : "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
"target" : "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-medication",
"element" : [
{
"code" : "EMSProtocol.procedures.medicationAdministration.medication.product.gtin",
"target" : [
{
"code" : "Medication.code.coding:GTIN",
"equivalence" : "equivalent"
}
]
},
{
"code" : "EMSProtocol.procedures.medicationAdministration.medication.product.atc",
"target" : [
{
"code" : "Medication.code.coding:ATC",
"equivalence" : "equivalent"
}
]
},
{
"code" : "EMSProtocol.procedures.medicationAdministration.medication.product.freeText",
"target" : [
{
"code" : "Medication.code.text",
"equivalence" : "equivalent"
}
]
},
{
"code" : "EMSProtocol.procedures.medicationAdministration.medication.ingredient",
"target" : [
{
"code" : "Medication.ingredient.itemCodeableConcept",
"equivalence" : "equivalent"
}
]
},
{
"code" : "EMSProtocol.procedures.medicationAdministration.medication.galenicForm",
"target" : [
{
"code" : "Medication.form",
"equivalence" : "equivalent"
}
]
},
{
"code" : "EMSProtocol.procedures.medicationAdministration.medication.packageSize",
"target" : [
{
"code" : "Medication.amount",
"equivalence" : "equivalent"
}
]
}
]
},
{
"source" : "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
"target" : "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-procedure-woundtreatment",
"element" : [
{
"code" : "EMSProtocol.procedures.woundTreatment",
"target" : [
{
"code" : "Procedure.code",
"equivalence" : "equivalent"
}
]
}
]
},
{
"source" : "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
"target" : "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-procedure-airways",
"element" : [
{
"code" : "EMSProtocol.procedures.airway.intervention",
"target" : [
{
"code" : "Procedure.code",
"equivalence" : "equivalent"
}
]
}
]
},
{
"source" : "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
"target" : "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-procedure-breathing",
"element" : [
{
"code" : "EMSProtocol.procedures.breathing.intervention",
"target" : [
{
"code" : "Procedure.code",
"equivalence" : "equivalent"
}
]
}
]
},
{
"source" : "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
"target" : "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-procedure",
"element" : [
{
"code" : "EMSProtocol.procedures.circulation.intervention",
"target" : [
{
"code" : "Procedure.code",
"equivalence" : "equivalent"
}
]
}
]
},
{
"source" : "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
"target" : "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-procedure",
"element" : [
{
"code" : "EMSProtocol.procedures.disability.intervention",
"target" : [
{
"code" : "Procedure.code",
"equivalence" : "equivalent"
}
]
}
]
},
{
"source" : "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
"target" : "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-procedure",
"element" : [
{
"code" : "EMSProtocol.procedures.exposure.intervention",
"target" : [
{
"code" : "Procedure.code",
"equivalence" : "equivalent"
}
]
}
]
}
]
}