IDEA4RC FHIR Implementation Guide
0.1.0 - CI Build 150

IDEA4RC FHIR Implementation Guide, published by IDEA4RC Project. This guide is not an authorized publication; it is the continuous build for version 0.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7-eu/idea4rc/ and changes regularly. See the Directory of published versions

Resource Profile: SarcomaCancerStageGroup - Detailed Descriptions

Draft as of 2024-11-12

Definitions for the sarcoma-cancer-stage-group resource profile.

Guidance on how to interpret the contents of this table can be found here

0. Observation
2. Observation.status
ShortThe status of the result
4. Observation.code
ShortWhat was observed
BindingFor example codes, see Cancer Stage Group: Athena
(example to http://hl7.eu/fhir/ig/idea4rc/ValueSet/cancer-stageGroup-athena-vs)
6. Observation.subject
Control1..?
TypeReference(Patient: IDEA4RC)
8. Observation.focus
TypeReference(Condition: Primary Cancer)
10. Observation.effective[x]
ShortClinically relevant time for observation
[x] NoteSeeChoice of Data Typesfor further information about how to use [x]
12. Observation.value[x]
ShortActual result.
BindingFor example codes, see Cancer Stage Group Value: Athena
(example to http://hl7.eu/fhir/ig/idea4rc/ValueSet/cancer-stageGroupValue-athena-vs)
TypeCodeableConcept, dateTime, boolean, string, SampledData, Quantity, Period, Ratio, integer, time, Range
[x] NoteSeeChoice of Data Typesfor further information about how to use [x]
14. Observation.method
ShortADD BINDING
16. Observation.device
Definition

Not used in this profile

ShortNot used in this profile
Control0..0
18. Observation.referenceRange
Definition

Not used in this profile

ShortNot used in this profile
Control0..0
20. Observation.hasMember
TypeReference(Observation)
SlicingThis element introduces a set of slices on Observation.hasMember. The slices areUnordered and Open, and can be differentiated using the following discriminators:
  • pattern @ $this.resolve().code
  • 22. Observation.hasMember:localized
    Slice Namelocalized
    Definition

    The stage at diagnosis (before any treatments) Localised (yes/no)

    ShortLocalized
    Comments

    When using this element, the Observation must validate against the specified profile.

    Control0..1
    TypeReference(Observation: Localized Category (Stage, Sarcoma))
    24. Observation.hasMember:locoRegional
    Slice NamelocoRegional
    Definition

    LocoRegional Category

    ShortLocoRegional Category
    Comments

    When using this element, the Observation must validate against the specified profile.

    Control0..1
    TypeReference(Observation: LocoRegional Category (Stage, Sarcoma))
    26. Observation.component
    Definition

    Not used in this profile

    ShortNot used in this profile
    Control0..0

    Guidance on how to interpret the contents of this table can be found here

    0. Observation
    Definition

    Measurements and simple assertions made about a patient, device or other subject.

    ShortMeasurements and simple assertions
    Comments

    Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.

    Control0..*
    Is Modifierfalse
    Summaryfalse
    Alternate NamesVital Signs, Measurement, Results, Tests
    Invariantsdom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty())
    dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty())
    dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty())
    dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty())
    dom-6: A resource should have narrative for robust management (text.`div`.exists())
    obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
    obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
    obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
    obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
    2. Observation.implicitRules
    Definition

    A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc.

    ShortA set of rules under which this content was created
    Comments

    Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc.

    Control0..1
    Typeuri
    Is Modifiertrue because This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies it's meaning or interpretation
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    Summarytrue
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    4. Observation.modifierExtension
    Definition

    May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

    Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

    ShortExtensions that cannot be ignored
    Comments

    There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

    Control0..*
    TypeExtension
    Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the resource that contains them
    Summaryfalse
    Requirements

    Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

    Alternate Namesextensions, user content
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
    6. Observation.status
    Definition

    The status of the result value.

    ShortThe status of the resultregistered | preliminary | final | amended +
    Comments

    This element is labeled as a modifier because the status contains codes that mark the resource as not currently valid.

    Control1..1
    BindingThe codes SHALL be taken from ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1
    (required to http://hl7.org/fhir/ValueSet/observation-status|4.0.1)

    Codes providing the status of an observation.

    Typecode
    Is Modifiertrue because This element is labeled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    Summarytrue
    Requirements

    Need to track the status of individual results. Some results are finalized before the whole report is finalized.

    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    8. Observation.code
    Definition

    Describes what was observed. Sometimes this is called the observation "name".

    ShortWhat was observedType of observation (code / type)
    Comments

    All code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

    Control1..1
    BindingFor example codes, see Cancer Stage Group: Athenahttp://hl7.org/fhir/ValueSet/observation-codes
    (example to http://hl7.eu/fhir/ig/idea4rc/ValueSet/cancer-stageGroup-athena-vs)
    TypeCodeableConcept
    Is Modifierfalse
    Summarytrue
    Requirements

    Knowing what kind of observation is being made is essential to understanding the observation.

    Alternate NamesName
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    10. Observation.subject
    Definition

    The patient, or group of patients, location, or device this observation is about and into whose record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the focus element or the code itself specifies the actual focus of the observation.

    ShortWho and/or what the observation is about
    Comments

    One would expect this element to be a cardinality of 1..1. The only circumstance in which the subject can be missing is when the observation is made by a device that does not know the patient. In this case, the observation SHALL be matched to a patient through some context/channel matching technique, and at this point, the observation should be updated.

    Control10..1
    TypeReference(Patient: IDEA4RC, Patient, Group, Device, Location)
    Is Modifierfalse
    Summarytrue
    Requirements

    Observations have no value if you don't know who or what they're about.

    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    12. Observation.focus
    Definition

    The actual focus of an observation when it is not the patient of record representing something or someone associated with the patient such as a spouse, parent, fetus, or donor. For example, fetus observations in a mother's record. The focus of an observation could also be an existing condition, an intervention, the subject's diet, another observation of the subject, or a body structure such as tumor or implanted device. An example use case would be using the Observation resource to capture whether the mother is trained to change her child's tracheostomy tube. In this example, the child is the patient of record and the mother is the focus.

    ShortWhat the observation is about, when it is not about the subject of record
    Comments

    Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., "Blood Glucose") and does not need to be represented separately using this element. Use specimen if a reference to a specimen is required. If a code is required instead of a resource use either bodysite for bodysites or the standard extension focusCode.

    Control0..*
    TypeReference(Condition: Primary Cancer, Resource)
    Is Modifierfalse
    Summarytrue
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    14. Observation.effective[x]
    Definition

    The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.

    ShortClinically relevant time for observationClinically relevant time/time-period for observation
    Comments

    At least a date should be present unless this observation is a historical report. For recording imprecise or "fuzzy" times (For example, a blood glucose measurement taken "after breakfast") use the Timing datatype which allow the measurement to be tied to regular life events.

    Control0..1
    TypeChoice of: dateTime, Period, Timing, instant
    [x] NoteSeeChoice of Data Typesfor further information about how to use [x]
    Is Modifierfalse
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    Summarytrue
    Requirements

    Knowing when an observation was deemed true is important to its relevance as well as determining trends.

    Alternate NamesOccurrence
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    16. Observation.value[x]
    Definition

    The information determined as a result of making the observation, if the information has a simple value.

    ShortActual result.
    Comments

    An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

    Control0..1
    This element is affected by the following invariants: obs-7
    BindingFor example codes, see For codes, see Cancer Stage Group Value: Athena
    (example to http://hl7.eu/fhir/ig/idea4rc/ValueSet/cancer-stageGroupValue-athena-vs)
    TypeCodeableConcept, dateTime, boolean, string, SampledData, Quantity, Period, Ratio, integer, time, Range
    [x] NoteSeeChoice of Data Typesfor further information about how to use [x]
    Is Modifierfalse
    Summarytrue
    Requirements

    An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    18. Observation.method
    Definition

    Indicates the mechanism used to perform the observation.

    ShortADD BINDINGHow it was done
    Comments

    Only used if not implicit in code for Observation.code.

    Control0..1
    BindingFor example codes, see ObservationMethodshttp://hl7.org/fhir/ValueSet/observation-methods
    (example to http://hl7.org/fhir/ValueSet/observation-methods)

    Methods for simple observations.

    TypeCodeableConcept
    Is Modifierfalse
    Summaryfalse
    Requirements

    In some cases, method can impact results and is thus used for determining whether results can be compared or determining significance of results.

    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    20. Observation.device
    Definition

    Not used in this profile


    The device used to generate the observation data.

    ShortNot used in this profile(Measurement) Device
    Comments

    Note that this is not meant to represent a device involved in the transmission of the result, e.g., a gateway. Such devices may be documented using the Provenance resource where relevant.

    Control0..01
    TypeReference(Device, DeviceMetric)
    Is Modifierfalse
    Summaryfalse
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    22. Observation.referenceRange
    Definition

    Not used in this profile


    Guidance on how to interpret the value by comparison to a normal or recommended range. Multiple reference ranges are interpreted as an "OR". In other words, to represent two distinct target populations, two referenceRange elements would be used.

    ShortNot used in this profileProvides guide for interpretation
    Comments

    Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

    Control0..0*
    TypeBackboneElement
    Is Modifierfalse
    Summaryfalse
    Requirements

    Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    obs-3: Must have at least a low or a high or text (low.exists() or high.exists() or text.exists())
    obs-3: Must have at least a low or a high or text (low.exists() or high.exists() or text.exists())
    25. Observation.hasMember
    Definition

    This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.

    ShortRelated resource that belongs to the Observation group
    Comments

    When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see Notes below. Note that a system may calculate results from QuestionnaireResponse into a final score and represent the score as an Observation.


    When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see Notes below. Note that a system may calculate results from QuestionnaireResponse into a final score and represent the score as an Observation.

    Control0..*
    TypeReference(Observation, QuestionnaireResponse, MolecularSequence)
    Is Modifierfalse
    Summarytrue
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    SlicingThis element introduces a set of slices on Observation.hasMember. The slices areUnordered and Open, and can be differentiated using the following discriminators:
    • pattern @ $this.resolve().code
    • 27. Observation.hasMember:localized
      Slice Namelocalized
      Definition

      The stage at diagnosis (before any treatments) Localised (yes/no)


      This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.

      ShortLocalizedRelated resource that belongs to the Observation group
      Comments

      When using this element, the Observation must validate against the specified profile.


      When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see Notes below. Note that a system may calculate results from QuestionnaireResponse into a final score and represent the score as an Observation.

      Control0..1*
      TypeReference(Observation: Localized Category (Stage, Sarcoma), Observation, QuestionnaireResponse, MolecularSequence)
      Is Modifierfalse
      Summarytrue
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      29. Observation.hasMember:locoRegional
      Slice NamelocoRegional
      Definition

      LocoRegional Category


      This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.

      ShortLocoRegional CategoryRelated resource that belongs to the Observation group
      Comments

      When using this element, the Observation must validate against the specified profile.


      When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see Notes below. Note that a system may calculate results from QuestionnaireResponse into a final score and represent the score as an Observation.

      Control0..1*
      TypeReference(Observation: LocoRegional Category (Stage, Sarcoma), Observation, QuestionnaireResponse, MolecularSequence)
      Is Modifierfalse
      Summarytrue
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      31. Observation.component
      Definition

      Not used in this profile


      Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

      ShortNot used in this profileComponent results
      Comments

      For a discussion on the ways Observations can be assembled in groups together see Notes below.

      Control0..0*
      TypeBackboneElement
      Is Modifierfalse
      Summarytrue
      Requirements

      Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))

      Guidance on how to interpret the contents of this table can be found here

      0. Observation
      Definition

      Measurements and simple assertions made about a patient, device or other subject.

      ShortMeasurements and simple assertions
      Comments

      Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.

      Control0..*
      Is Modifierfalse
      Summaryfalse
      Alternate NamesVital Signs, Measurement, Results, Tests
      Invariantsdom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty())
      dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty())
      dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty())
      dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty())
      dom-6: A resource should have narrative for robust management (text.`div`.exists())
      obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
      obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
      2. Observation.id
      Definition

      The logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes.

      ShortLogical id of this artifact
      Comments

      The only time that a resource does not have an id is when it is being submitted to the server using a create operation.

      Control0..1
      Typeid
      Is Modifierfalse
      Summarytrue
      4. Observation.meta
      Definition

      The metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource.

      ShortMetadata about the resource
      Control0..1
      TypeMeta
      Is Modifierfalse
      Summarytrue
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      6. Observation.implicitRules
      Definition

      A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc.

      ShortA set of rules under which this content was created
      Comments

      Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc.

      Control0..1
      Typeuri
      Is Modifiertrue because This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies it's meaning or interpretation
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Summarytrue
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      8. Observation.language
      Definition

      The base language in which the resource is written.

      ShortLanguage of the resource content
      Comments

      Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute).

      Control0..1
      BindingThe codes SHOULD be taken from CommonLanguages
      (preferred to http://hl7.org/fhir/ValueSet/languages)

      A human language.

      Additional BindingsPurpose
      AllLanguagesMax Binding
      Typecode
      Is Modifierfalse
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Summaryfalse
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      10. Observation.text
      Definition

      A human-readable narrative that contains a summary of the resource and can be used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Resource definitions may define what content should be represented in the narrative to ensure clinical safety.

      ShortText summary of the resource, for human interpretation
      Comments

      Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later.

      Control0..1
      TypeNarrative
      Is Modifierfalse
      Summaryfalse
      Alternate Namesnarrative, html, xhtml, display
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      12. Observation.contained
      Definition

      These resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, and nor can they have their own independent transaction scope.

      ShortContained, inline Resources
      Comments

      This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels.

      Control0..*
      TypeResource
      Is Modifierfalse
      Summaryfalse
      Alternate Namesinline resources, anonymous resources, contained resources
      14. Observation.extension
      Definition

      May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

      ShortAdditional content defined by implementations
      Comments

      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

      Control0..*
      TypeExtension
      Is Modifierfalse
      Summaryfalse
      Alternate Namesextensions, user content
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
      16. Observation.modifierExtension
      Definition

      May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

      Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

      ShortExtensions that cannot be ignored
      Comments

      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

      Control0..*
      TypeExtension
      Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the resource that contains them
      Summaryfalse
      Requirements

      Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

      Alternate Namesextensions, user content
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
      18. Observation.identifier
      Definition

      A unique identifier assigned to this observation.

      ShortBusiness Identifier for observation
      NoteThis is a business identifier, not a resource identifier (see discussion)
      Control0..*
      TypeIdentifier
      Is Modifierfalse
      Summarytrue
      Requirements

      Allows observations to be distinguished and referenced.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      20. Observation.basedOn
      Definition

      A plan, proposal or order that is fulfilled in whole or in part by this event. For example, a MedicationRequest may require a patient to have laboratory test performed before it is dispensed.

      ShortFulfills plan, proposal or order
      Control0..*
      TypeReference(CarePlan, DeviceRequest, ImmunizationRecommendation, MedicationRequest, NutritionOrder, ServiceRequest)
      Is Modifierfalse
      Summarytrue
      Requirements

      Allows tracing of authorization for the event and tracking whether proposals/recommendations were acted upon.

      Alternate NamesFulfills
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      22. Observation.partOf
      Definition

      A larger event of which this particular Observation is a component or step. For example, an observation as part of a procedure.

      ShortPart of referenced event
      Comments

      To link an Observation to an Encounter use encounter. See the Notes below for guidance on referencing another Observation.

      Control0..*
      TypeReference(MedicationAdministration, MedicationDispense, MedicationStatement, Procedure, Immunization, ImagingStudy)
      Is Modifierfalse
      Summarytrue
      Alternate NamesContainer
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      24. Observation.status
      Definition

      The status of the result value.

      ShortThe status of the result
      Comments

      This element is labeled as a modifier because the status contains codes that mark the resource as not currently valid.

      Control1..1
      BindingThe codes SHALL be taken from ObservationStatus
      (required to http://hl7.org/fhir/ValueSet/observation-status|4.0.1)

      Codes providing the status of an observation.

      Typecode
      Is Modifiertrue because This element is labeled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Summarytrue
      Requirements

      Need to track the status of individual results. Some results are finalized before the whole report is finalized.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      26. Observation.category
      Definition

      A code that classifies the general type of observation being made.

      ShortClassification of type of observation
      Comments

      In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

      Control0..*
      BindingThe codes SHOULD be taken from ObservationCategoryCodes
      (preferred to http://hl7.org/fhir/ValueSet/observation-category)

      Codes for high level observation categories.

      TypeCodeableConcept
      Is Modifierfalse
      Summaryfalse
      Requirements

      Used for filtering what observations are retrieved and displayed.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      28. Observation.code
      Definition

      Describes what was observed. Sometimes this is called the observation "name".

      ShortWhat was observed
      Comments

      All code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

      Control1..1
      BindingFor example codes, see Cancer Stage Group: Athena
      (example to http://hl7.eu/fhir/ig/idea4rc/ValueSet/cancer-stageGroup-athena-vs)
      TypeCodeableConcept
      Is Modifierfalse
      Summarytrue
      Requirements

      Knowing what kind of observation is being made is essential to understanding the observation.

      Alternate NamesName
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      30. Observation.subject
      Definition

      The patient, or group of patients, location, or device this observation is about and into whose record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the focus element or the code itself specifies the actual focus of the observation.

      ShortWho and/or what the observation is about
      Comments

      One would expect this element to be a cardinality of 1..1. The only circumstance in which the subject can be missing is when the observation is made by a device that does not know the patient. In this case, the observation SHALL be matched to a patient through some context/channel matching technique, and at this point, the observation should be updated.

      Control1..1
      TypeReference(Patient: IDEA4RC)
      Is Modifierfalse
      Summarytrue
      Requirements

      Observations have no value if you don't know who or what they're about.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      32. Observation.focus
      Definition

      The actual focus of an observation when it is not the patient of record representing something or someone associated with the patient such as a spouse, parent, fetus, or donor. For example, fetus observations in a mother's record. The focus of an observation could also be an existing condition, an intervention, the subject's diet, another observation of the subject, or a body structure such as tumor or implanted device. An example use case would be using the Observation resource to capture whether the mother is trained to change her child's tracheostomy tube. In this example, the child is the patient of record and the mother is the focus.

      ShortWhat the observation is about, when it is not about the subject of record
      Comments

      Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., "Blood Glucose") and does not need to be represented separately using this element. Use specimen if a reference to a specimen is required. If a code is required instead of a resource use either bodysite for bodysites or the standard extension focusCode.

      Control0..*
      TypeReference(Condition: Primary Cancer)
      Is Modifierfalse
      Summarytrue
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      34. Observation.encounter
      Definition

      The healthcare event (e.g. a patient and healthcare provider interaction) during which this observation is made.

      ShortHealthcare event during which this observation is made
      Comments

      This will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission laboratory tests).

      Control0..1
      TypeReference(Encounter)
      Is Modifierfalse
      Summarytrue
      Requirements

      For some observations it may be important to know the link between an observation and a particular encounter.

      Alternate NamesContext
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      36. Observation.effective[x]
      Definition

      The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.

      ShortClinically relevant time for observation
      Comments

      At least a date should be present unless this observation is a historical report. For recording imprecise or "fuzzy" times (For example, a blood glucose measurement taken "after breakfast") use the Timing datatype which allow the measurement to be tied to regular life events.

      Control0..1
      TypeChoice of: dateTime, Period, Timing, instant
      [x] NoteSeeChoice of Data Typesfor further information about how to use [x]
      Is Modifierfalse
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Summarytrue
      Requirements

      Knowing when an observation was deemed true is important to its relevance as well as determining trends.

      Alternate NamesOccurrence
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      38. Observation.issued
      Definition

      The date and time this version of the observation was made available to providers, typically after the results have been reviewed and verified.

      ShortDate/Time this version was made available
      Comments

      For Observations that don’t require review and verification, it may be the same as the lastUpdated time of the resource itself. For Observations that do require review and verification for certain updates, it might not be the same as the lastUpdated time of the resource itself due to a non-clinically significant update that doesn’t require the new version to be reviewed and verified again.

      Control0..1
      Typeinstant
      Is Modifierfalse
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Summarytrue
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      40. Observation.performer
      Definition

      Who was responsible for asserting the observed value as "true".

      ShortWho is responsible for the observation
      Control0..*
      TypeReference(Practitioner, PractitionerRole, Organization, CareTeam, Patient, RelatedPerson)
      Is Modifierfalse
      Summarytrue
      Requirements

      May give a degree of confidence in the observation and also indicates where follow-up questions should be directed.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      42. Observation.value[x]
      Definition

      The information determined as a result of making the observation, if the information has a simple value.

      ShortActual result.
      Comments

      An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

      Control0..1
      This element is affected by the following invariants: obs-7
      BindingFor example codes, see Cancer Stage Group Value: Athena
      (example to http://hl7.eu/fhir/ig/idea4rc/ValueSet/cancer-stageGroupValue-athena-vs)
      TypeCodeableConcept
      [x] NoteSeeChoice of Data Typesfor further information about how to use [x]
      Is Modifierfalse
      Summarytrue
      Requirements

      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      44. Observation.dataAbsentReason
      Definition

      Provides a reason why the expected value in the element Observation.value[x] is missing.

      ShortWhy the result is missing
      Comments

      Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "specimen unsatisfactory".

      The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Note that an observation may only be reported if there are values to report. For example differential cell counts values may be reported only when > 0. Because of these options, use-case agreements are required to interpret general observations for null or exceptional values.

      Control0..1
      This element is affected by the following invariants: obs-6
      BindingUnless not suitable, these codes SHALL be taken from DataAbsentReason
      (extensible to http://hl7.org/fhir/ValueSet/data-absent-reason)

      Codes specifying why the result (Observation.value[x]) is missing.

      TypeCodeableConcept
      Is Modifierfalse
      Summaryfalse
      Requirements

      For many results it is necessary to handle exceptional values in measurements.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      46. Observation.interpretation
      Definition

      A categorical assessment of an observation value. For example, high, low, normal.

      ShortHigh, low, normal, etc.
      Comments

      Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

      Control0..*
      BindingUnless not suitable, these codes SHALL be taken from ObservationInterpretationCodes
      (extensible to http://hl7.org/fhir/ValueSet/observation-interpretation)

      Codes identifying interpretations of observations.

      TypeCodeableConcept
      Is Modifierfalse
      Summaryfalse
      Requirements

      For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

      Alternate NamesAbnormal Flag
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      48. Observation.note
      Definition

      Comments about the observation or the results.

      ShortComments about the observation
      Comments

      May include general statements about the observation, or statements about significant, unexpected or unreliable results values, or information about its source when relevant to its interpretation.

      Control0..*
      TypeAnnotation
      Is Modifierfalse
      Summaryfalse
      Requirements

      Need to be able to provide free text additional information.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      50. Observation.bodySite
      Definition

      Indicates the site on the subject's body where the observation was made (i.e. the target site).

      ShortObserved body part
      Comments

      Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component.

      If the use case requires BodySite to be handled as a separate resource (e.g. to identify and track separately) then use the standard extension bodySite.

      Control0..1
      BindingFor example codes, see SNOMEDCTBodyStructures
      (example to http://hl7.org/fhir/ValueSet/body-site)

      Codes describing anatomical locations. May include laterality.

      TypeCodeableConcept
      Is Modifierfalse
      Summaryfalse
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      52. Observation.method
      Definition

      Indicates the mechanism used to perform the observation.

      ShortADD BINDING
      Comments

      Only used if not implicit in code for Observation.code.

      Control0..1
      BindingFor example codes, see ObservationMethods
      (example to http://hl7.org/fhir/ValueSet/observation-methods)

      Methods for simple observations.

      TypeCodeableConcept
      Is Modifierfalse
      Summaryfalse
      Requirements

      In some cases, method can impact results and is thus used for determining whether results can be compared or determining significance of results.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      54. Observation.specimen
      Definition

      The specimen that was used when this observation was made.

      ShortSpecimen used for this observation
      Comments

      Should only be used if not implicit in code found in Observation.code. Observations are not made on specimens themselves; they are made on a subject, but in many cases by the means of a specimen. Note that although specimens are often involved, they are not always tracked and reported explicitly. Also note that observation resources may be used in contexts that track the specimen explicitly (e.g. Diagnostic Report).

      Control0..1
      TypeReference(Specimen)
      Is Modifierfalse
      Summaryfalse
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      56. Observation.device
      Definition

      Not used in this profile

      ShortNot used in this profile
      Comments

      Note that this is not meant to represent a device involved in the transmission of the result, e.g., a gateway. Such devices may be documented using the Provenance resource where relevant.

      Control0..0
      TypeReference(Device, DeviceMetric)
      Is Modifierfalse
      Summaryfalse
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      58. Observation.referenceRange
      Definition

      Not used in this profile

      ShortNot used in this profile
      Comments

      Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

      Control0..0
      TypeBackboneElement
      Is Modifierfalse
      Summaryfalse
      Requirements

      Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      obs-3: Must have at least a low or a high or text (low.exists() or high.exists() or text.exists())
      69. Observation.hasMember
      Definition

      This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.

      ShortRelated resource that belongs to the Observation group
      Comments

      When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see Notes below. Note that a system may calculate results from QuestionnaireResponse into a final score and represent the score as an Observation.

      Control0..*
      TypeReference(Observation)
      Is Modifierfalse
      Summarytrue
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      SlicingThis element introduces a set of slices on Observation.hasMember. The slices areUnordered and Open, and can be differentiated using the following discriminators:
      • pattern @ $this.resolve().code
      • 71. Observation.hasMember:localized
        Slice Namelocalized
        Definition

        The stage at diagnosis (before any treatments) Localised (yes/no)

        ShortLocalized
        Comments

        When using this element, the Observation must validate against the specified profile.

        Control0..1
        TypeReference(Observation: Localized Category (Stage, Sarcoma))
        Is Modifierfalse
        Summarytrue
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        73. Observation.hasMember:locoRegional
        Slice NamelocoRegional
        Definition

        LocoRegional Category

        ShortLocoRegional Category
        Comments

        When using this element, the Observation must validate against the specified profile.

        Control0..1
        TypeReference(Observation: LocoRegional Category (Stage, Sarcoma))
        Is Modifierfalse
        Summarytrue
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        75. Observation.derivedFrom
        Definition

        The target resource that represents a measurement from which this observation value is derived. For example, a calculated anion gap or a fetal measurement based on an ultrasound image.

        ShortRelated measurements the observation is made from
        Comments

        All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see Notes below.

        Control0..*
        TypeReference(DocumentReference, ImagingStudy, Media, QuestionnaireResponse, Observation, MolecularSequence)
        Is Modifierfalse
        Summarytrue
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        77. Observation.component
        Definition

        Not used in this profile

        ShortNot used in this profile
        Comments

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Control0..0
        TypeBackboneElement
        Is Modifierfalse
        Summarytrue
        Requirements

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))