IDEA4RC FHIR Implementation Guide
0.1.0 - CI Build 150

IDEA4RC FHIR Implementation Guide, published by IDEA4RC Project. This guide is not an authorized publication; it is the continuous build for version 0.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7-eu/idea4rc/ and changes regularly. See the Directory of published versions

Resource Profile: TNMDistantMetastasesCategory - Detailed Descriptions

Draft as of 2025-01-09

Definitions for the mcode-tnm-distant-metastases-category resource profile.

Guidance on how to interpret the contents of this table can be found here

0. Observation
Definition

Measurements and simple assertions made about a patient, device or other subject.

ShortMeasurements and simple assertions
Comments

Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.

Control0..*
Is Modifierfalse
Summaryfalse
Alternate NamesVital Signs, Measurement, Results, Tests
Invariantsdom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty())
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty())
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty())
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty())
dom-6: A resource should have narrative for robust management (text.`div`.exists())
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
2. Observation.implicitRules
Definition

A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc.

ShortA set of rules under which this content was created
Comments

Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc.

Control0..1
Typeuri
Is Modifiertrue because This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies it's meaning or interpretation
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summarytrue
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
4. Observation.modifierExtension
Definition

May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

ShortExtensions that cannot be ignored
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the resource that contains them
Summaryfalse
Requirements

Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

Alternate Namesextensions, user content
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
6. Observation.status
Definition

The status of the result value.

ShortThe status of the resultregistered | preliminary | final | amended +
Comments

This element is labeled as a modifier because the status contains codes that mark the resource as not currently valid.

Control1..1
BindingThe codes SHALL be taken from ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1
(required to http://hl7.org/fhir/ValueSet/observation-status|4.0.1)

Codes providing the status of an observation.

Typecode
Is Modifiertrue because This element is labeled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summarytrue
Requirements

Need to track the status of individual results. Some results are finalized before the whole report is finalized.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
8. Observation.code
Definition

Describes what was observed. Sometimes this is called the observation "name".

ShortWhat was observedType of observation (code / type)
Comments

All code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

Control1..1
BindingThe codes SHALL be taken from For example codes, see Observation Codes for Distant Metastases Categoryhttp://hl7.org/fhir/ValueSet/observation-codes
(required to http://hl7.eu/fhir/ig/idea4rc/ValueSet/mcode-observation-codes-distant-metastases-vs)
TypeCodeableConcept
Is Modifierfalse
Summarytrue
Requirements

Knowing what kind of observation is being made is essential to understanding the observation.

Alternate NamesName
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
10. Observation.subject
Definition

The patient, or group of patients, location, or device this observation is about and into whose record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the focus element or the code itself specifies the actual focus of the observation.

ShortWho and/or what the observation is about
Comments

One would expect this element to be a cardinality of 1..1. The only circumstance in which the subject can be missing is when the observation is made by a device that does not know the patient. In this case, the observation SHALL be matched to a patient through some context/channel matching technique, and at this point, the observation should be updated.

Control10..1
TypeReference(Patient: IDEA4RC, Patient, Group, Device, Location)
Is Modifierfalse
Summarytrue
Requirements

Observations have no value if you don't know who or what they're about.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
12. Observation.focus
Definition

The actual focus of an observation when it is not the patient of record representing something or someone associated with the patient such as a spouse, parent, fetus, or donor. For example, fetus observations in a mother's record. The focus of an observation could also be an existing condition, an intervention, the subject's diet, another observation of the subject, or a body structure such as tumor or implanted device. An example use case would be using the Observation resource to capture whether the mother is trained to change her child's tracheostomy tube. In this example, the child is the patient of record and the mother is the focus.

ShortWhat the observation is about, when it is not about the subject of record
Comments

Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., "Blood Glucose") and does not need to be represented separately using this element. Use specimen if a reference to a specimen is required. If a code is required instead of a resource use either bodysite for bodysites or the standard extension focusCode.

Control0..*
TypeReference(Condition: Primary Cancer, Resource)
Is Modifierfalse
Summarytrue
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
14. Observation.effective[x]
Definition

The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.

ShortClinically relevant time for observationClinically relevant time/time-period for observation
Comments

At least a date should be present unless this observation is a historical report. For recording imprecise or "fuzzy" times (For example, a blood glucose measurement taken "after breakfast") use the Timing datatype which allow the measurement to be tied to regular life events.

Control0..1
TypeChoice of: dateTime, Period, Timing, instant
[x] NoteSeeChoice of Data Typesfor further information about how to use [x]
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summarytrue
Requirements

Knowing when an observation was deemed true is important to its relevance as well as determining trends.

Alternate NamesOccurrence
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
16. Observation.value[x]
Definition

The information determined as a result of making the observation, if the information has a simple value.

ShortActual result.
Comments

An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

Control0..1
This element is affected by the following invariants: obs-7
BindingThe codes SHOULD be taken from For codes, see TNM Distant Metastases Category Value Set
(preferred to http://hl7.eu/fhir/ig/idea4rc/ValueSet/mcode-tnm-distant-metastases-category-vs)
TypeCodeableConcept, dateTime, boolean, string, SampledData, Quantity, Period, Ratio, integer, time, Range
[x] NoteSeeChoice of Data Typesfor further information about how to use [x]
Is Modifierfalse
Summarytrue
Requirements

An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
18. Observation.method
Definition

Indicates the mechanism used to perform the observation.

ShortADD BINDINGHow it was done
Comments

Only used if not implicit in code for Observation.code.

Control0..1
BindingFor example codes, see ObservationMethodshttp://hl7.org/fhir/ValueSet/observation-methods
(example to http://hl7.org/fhir/ValueSet/observation-methods)

Methods for simple observations.

TypeCodeableConcept
Is Modifierfalse
Summaryfalse
Requirements

In some cases, method can impact results and is thus used for determining whether results can be compared or determining significance of results.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
20. Observation.device
Definition

Not used in this profile


The device used to generate the observation data.

ShortNot used in this profile(Measurement) Device
Comments

Note that this is not meant to represent a device involved in the transmission of the result, e.g., a gateway. Such devices may be documented using the Provenance resource where relevant.

Control0..01
TypeReference(Device, DeviceMetric)
Is Modifierfalse
Summaryfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
22. Observation.referenceRange
Definition

Not used in this profile


Guidance on how to interpret the value by comparison to a normal or recommended range. Multiple reference ranges are interpreted as an "OR". In other words, to represent two distinct target populations, two referenceRange elements would be used.

ShortNot used in this profileProvides guide for interpretation
Comments

Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

Control0..0*
TypeBackboneElement
Is Modifierfalse
Summaryfalse
Requirements

Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
obs-3: Must have at least a low or a high or text (low.exists() or high.exists() or text.exists())
obs-3: Must have at least a low or a high or text (low.exists() or high.exists() or text.exists())
25. Observation.hasMember
Definition

Not used in this profile


This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.

ShortNot used in this profileRelated resource that belongs to the Observation group
Comments

When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see Notes below. Note that a system may calculate results from QuestionnaireResponse into a final score and represent the score as an Observation.


When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see Notes below. Note that a system may calculate results from QuestionnaireResponse into a final score and represent the score as an Observation.

Control0..0*
TypeReference(Observation, QuestionnaireResponse, MolecularSequence)
Is Modifierfalse
Summarytrue
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
27. Observation.component
Definition

Not used in this profile


Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

ShortNot used in this profileComponent results
Comments

For a discussion on the ways Observations can be assembled in groups together see Notes below.

Control0..0*
TypeBackboneElement
Is Modifierfalse
Summarytrue
Requirements

Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))