IDEA4RC FHIR Implementation Guide, published by IDEA4RC Project. This guide is not an authorized publication; it is the continuous build for version 0.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7-eu/idea4rc/ and changes regularly. See the Directory of published versions
| Draft as of 2026-08-07 |
Mappings for the Radiotherapy logical model.
| Name | Radiotherapy2FHIR![]() |
|---|---|
![]() |
|
![]() ![]() |
|
![]() ![]() |
|
![]() ![]() |
|
![]() ![]() |
Related To Procedure.extension:procedureIntent (from mcode https://build.fhir.org/ig/HL7/fhir-mCODE-ig/StructureDefinition-mcode-radiotherapy-course-summary.html) |
![]() ![]() |
|
![]() ![]() |
Equivalent To Procedure.extension:modalityAndTechnique.extension:modality.value[x] (Use valueCodeableConcept. For now we can use the mcode extension) |
![]() ![]() |
Equivalent To Procedure.extension:modalityAndTechnique.extension:modality.value[x] (Use element valueCodeableConcept.text) |
![]() ![]() |
Equivalent To Procedure.extension:modalityAndTechnique.extension:technique.value[x] (Use valueCodeableConcept. For now we can use the mcode extension) |
![]() ![]() |
Equivalent To Procedure.extension:doseToVolume (Use extension:totalDoseDelivered) |
![]() ![]() |
|
![]() ![]() |
Equivalent To Procedure.extension:doseToVolume (Use extension:fractionsDelivered) |
![]() ![]() |
Equivalent To Procedure.extension:adaptive (Use value.) |
![]() ![]() |
Related To Procedure.extension:modalityAndTechnique.extension:technique.value[x] (If is present the extension with code 2000100046 'Image guided radiotherapy (IGRT)' it is 'true', else it is 'false') |
![]() ![]() |
Related To Procedure (If is present another procedure in the same site for the same condition it is 'true', else it is 'false') |
![]() ![]() |
Equivalent To Procedure.reasonCode (Present only in the second procedure with the same site for the same condition) |
![]() ![]() |
|
![]() ![]() |
|
![]() ![]() |
Related To Procedure.bodySite (If bodySite = 1 and is the same of the Condition: Primary Cancer it is 'true', else it is 'false') |
![]() ![]() |
Related To Procedure.bodySite (If bodySite = 1 and is 36770046 'Neck' it is 'true', else it is 'false') |
![]() ![]() |
Related To Procedure.bodySite (If bodySite > 1 and one is the same of the Condition: Primary Cancer and another is 36770046 'Neck' with Procedure.bosySite.extension:lateralityQualifier 4112106 'Ipsilateral' it is 'true', else it is 'false') |
![]() ![]() |
Related To Procedure.bodySite (If bodySite > 1 and one is the same of the Condition: Primary Cancer and another is 36770046 'Neck' with Procedure.bosySite.extension:lateralityQualifier 4197258 'Right and left' it is 'true', else it is 'false') |
![]() ![]() |
Related To Procedure.bodySite (If is 36769180 'Metastasis' it is 'true', else it is 'false') |
![]() ![]() |
|
![]() ![]() |
Related To Procedure.bodySite (If is 36770283 'Metastasis to lung' it is 'true', else it is 'false') |
![]() ![]() |
Related To Procedure.bodySite (If is 35225542 'Metastasis to mediastinum' it is 'true', else it is 'false') |
![]() ![]() |
Related To Procedure.bodySite (If is 36769301 'Metastasis to bone' it is 'true', else it is 'false') |
![]() ![]() |
Related To Procedure.bodySite (If is 35225724 'Metastasis to soft tissues' it is 'true', else it is 'false') |
![]() ![]() |
Related To Procedure.bodySite (If is 36770544 'Metastasis to liver' it is 'true', else it is 'false') |
![]() ![]() |
Equivalent To Procedure.extension:terminationReason (For now we can use the mcode extension) |
![]() ![]() |
|
![]() ![]() |
|
Documentation for this format | |
No Mappings Found
No Mappings Found