eHealth Infrastructure, published by Den telemedicinske infrastruktur (eHealth Infrastructure). This guide is not an authorized publication; it is the continuous build for version 3.3.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/fut-infrastructure/implementation-guide/ and changes regularly. See the Directory of published versions
GENERAL_RESOURCE_NOT_FOUND
: Resource %s with id %s is not found.
GENERAL_SUBJECT_AND_CONTEXT_NOT_PROVIDED
: At least one of subject and context must be provided.
GENERAL_VALIDATION_ERROR
: Validation error: %s
GENERAL_EXPORT_FAILED
: Export resource has failed.
GENERAL_CANONICAL_TARGET_NOT_ALLOWED_ERROR
: Unsupported target in canonical: %s
GENERAL_NAMING_SYSTEM_NOT_FOUND
: NamingSystem with identifier %s is not found.
ACTIONGUIDANCEVIEW_ILLEGAL_CONTENT_SIZE
: Size of content is greater than the max allowed size. Content size: %s, max size: %s
ACTIONGUIDANCEVIEW_ILLEGAL_STATUS_CHANGE
: Illegal status change for action_guidance or view from %s and to %s
ACTIONGUIDANCEVIEW_ILLEGAL_CHANGE_OF_ELEMENTS
: Illegal element change in either EHealthActonGuidance or EhealthView. If status is equal to Active or Retired, only the following elements can be changed (Recommendation, IntendedAudience, useContext, modifierrole and status)
ACTIVITYDEFINITION_UPDATE_ALLOWED_FOR_STATUS
: Update is only allowed for ActivityDefinition with status: %s or %s.
ACTIVITYDEFINITION_UPDATE_TO_NOT_ALLOWED_STATE
: Update is not allowed for ActivityDefinition with %s status to different than %s status.
ACTIVITYDEFINITION_SHARINGAPPROVALPOLICY_NOT_ALLOWED : Resource %s does not allow SharingApprovalPolicy to be set with code: %s |
%s. |
ACTIVITYDEFINITION_SHARINGAPPROVALPOLICY_NOT_SET : Resource %s with code: %s |
%s must have SharingApprovalPolicy set. |
APPOINTMENT_LISTENER_APPOINTMENT_MISSING_CAREPLAN
: Appointment has no CarePlanASSEMBLER_QRD_FOUND_NON_OR_SEVERAL_MATCHES_FOR_QFDD_DOCUMENT_REFERENCE
: Found non or more than 1 match for QFDD DocumentReference. Identifier: system: %s, value: %s.
ASSEMBLER_QRD_NOT_ABLE_TO_DETERMINE_QFDD_REFERENCE
: Not able to determine QFDD reference from questionnaire.identifier. Non or more than 1 identifier system starting with 'urn:oid'. Questionnaire: %s.
ASSEMBLER_QRD_QR_SOURCE_IS_UNSUPPORTED
: QuestionnaireResponse with id: '%s' has source '%s', which is not supported - Skipping publication
ASSEMBLER_APD_MISSING_SUPPORTING_INFORMATION
: Appointment must have supportingInformation
ASSEMBLER_APD_MISSING_PATIENT_PARTICIPANT
: Appointment must have at least one Patient participant
ASSEMBLER_APD_MISSING_RESPONSIBLE_ORGANIZATION
: Appointment must have responsible-organization
ASSEMBLER_APD_MISSING_PERFORMER
: Appointment must have performer
ASSEMBLER_APD_MISSING_RESPONSIBLE_PRACTITIONER
: Appointment must have responsible Practitioner
ASSEMBLER_APD_MISSING_PATIENT_CPR
: Patient has no CPR number
ASSEMBLER_PHMR_UNKNOWN_AUTHOR_TYPE
: Unknown author type:
CAREPLAN_APPLY_NO_PLANDEFINITION
: There is no PlanDefinition with id %s
CAREPLAN_APPLY_NOT_ACTIVE_PLANDEFINITION
: The apply operation can only be performed on Plandefinitions with status "active"
CAREPLAN_APPLY_EPISODE_OF_CARE_REFERENCE_NOT_SPECIFIED
: EpisodeOfCare reference must be specified
CAREPLAN_APPLY_PLAN_DEFINITION_REFERENCE_NOT_SPECIFIED
: PlanDefinition reference must be specified
CAREPLAN_APPLY_CAN_NOT_FIND_ACTIVITY_DEFINITION
: Can not find activity definition with id :%s
CAREPLAN_NOT_FOUND
: CarePlan is not found.
CAREPLAN_SEARCH_SUBJECT_CONTEXT_OR_RESPONSIBLE_ACTOR_IS_NOT_SPECIFIED
: At least subject, context or responsible actor must be specified
CARETEAM_GENERAL_EXTERNAL_SECURITY_TOKEN_CARETEAM_IDENTIFIER_SYSTEM_IS_MISSING
: The CareTeam must contain an identifier using system "urn:ietf:rfc:3986"CDA_XML_VALIDATION_FAILED
: Validation of the CDA XML failed: %sCOMMUNICATIONREQUEST_CONTEXT_NOT_MATCHING_SERVICEREQUEST
: The context for the CommunicationRequest: %s does not match the context of the referenced ServiceRequest: %s
COMMUNICATIONREQUEST_SUBJECT_NOT_MATCHING_RECIPIENT
: Patient recipient: %s does not match the subject: %s
COMMUNICATIONREQUEST_SUBJECT_NOT_MATCHING_SERVICEREQUEST
: The subject for the CommunicationRequest: %s does not match the subject of the referenced ServiceRequest: %s
COMMUNICATIONREQUEST_EXCACTLY_ONE_RECIPIENT_SEARCHPRARAM
: Excactly one recipient search parameter required
CONTEXT_VALIDATION_EPISODEOFCARE_EXCEPTION
: Episode of care does not match the security token contextDEFINITION_WITHOUT_SELF_TREATMENT_TOPIC
: %s has to be with self-treatment topicDEVICE_WRITE_WRONG_PATIENT_CONTEXT
: User with patient context can only read devices that has been issued to the patient
DEVICE_WRITE_WRONG_ORGANIZATION_CONTEXT
: User must be logged into the organization that is the owner of the device
DEVICE_METRIC_WRITE_WRONG_ORGANIZATION_CONTEXT
: User must be logged into the organization that is the owner of the device
DEVICE_USE_STATEMENT_WRITE_WRONG_ORGANIZATION_CONTEXT
: User must be logged into the organization that is the owner of the device
DEVICE_WRONG_PATIENT_CONTEXT
: User with patient context can only interact with devices that has been issued to the patient or not issued to anyone yet
DEVICE_WRITE_NON_PRIVATELY_OWNED
: Patient user can only create/update privately owned devices
DOCUMENT_NOT_OF_TYPE_QFDD
: The document is expected to be of type QFDD
DOCUMENT_QUERY_SOR_ORGANIZATION_REQUIRED
: Security token organization context must be a SOR organization for query
DOCUMENT_QUERY_XDS_ERROR
: The following errors where received from Document Sharing
DOCUMENT_QUERY_DOCUMENT_URL_NOT_CORRECT_FORMAT
: Url doesn't have expected format:
DOCUMENT_QUERY_DOCUMENT_NOT_VALID_TYPE
: Requested document type is not valid. The requested type was %s, but the operation only supports %s
DOCUMENT_QUERY_DOCUMENT_NOT_VALID_XML
: Retrieved document is not valid XML
DOCUMENT_QUERY_REASON_NOT_PRESENT_WHEN_CONSENT_OVERRIDDEN
: Reason is mandatory when the consent is overridden
DOCUMENTREFERENCE_SUBJECT_REFER_TO_PATIENT
: It is not possible to set a patient as a subject for a Document referenceEPISODEOFCARE_CREATE_WRONG_EOC_COUNT
: Bundle has to contain only one Episode of Care
EPISODEOFCARE_CREATE_UNSUPPORTED_RESOURCE_TYPE
: Bundle contains unsupported resource type
EPISODEOFCARE_CREATE_INCORRECT_PROVENANCE_TARGET
: Provenance has incorrect target
EPISODEOFCARE_CREATE_NO_REQUIRED_PROVENANCE_POLICIES
: No provenance with required policies
EPISODEOFCARE_CREATE_INCORRECT_CONDITION_SUBJECT
: EpisodeOfCare and Condition doesn't point to the same Patient
EPISODEOFCARE_PATCH_NO_CONSENT
: No valid Episode Of Care related consent
EPISODEOFCARE_CREATE_PATIENT_MUST_BE_ACTIVE_AND_NOT_DECEASED
: Patient.active must be true and Patient.deceased must be false to create episode of care
EPISODEOFCARE_CREATE_STATUS_HISTORY_NOT_EMPTY
: It is not allowed to fill status history manually
EPISODEOFCARE_CREATE_EPISODE_OF_CARE_IN_NON_PLANNED_STATUS
: It is only possible to create an episode of care in status 'Planned'
EPISODEOFCARE_CREATE_TEAM_HISTORY_NOT_EMPTY
: It is not allowed to fill team history manually
EPISODEOFCARE_CREATE_PATIENT_DOESNT_MATCH_CONTEXT
: Episode of care patient doesn't match to the context
EPISODEOFCARE_IS_CONTEXT_ALLOWED_MATCH_NOT_FOUND
: It is not possible to set the Episode Of Care as a context
LIBRARY_EVALUATE_NO_INPUT_PARAMETER
: An input parameter of type Parameters should be provided.
LIBRARY_EVALUATE_INCORRECT_INPUT_PARAMETER
: Input parameter 'parameters' should contain exactly one resource of type QuestionnaireResponse, Observation or Media.
LIBRARY_EVALUATE_NO_RULE_DEFINED
: Library with id %s do not contain a rule to use for evaluation.
LIBRARY_EVALUATE_NO_CAREPLAN_REFERENCING_PROVIDED_PROCEDUREQUEST
: CarePlan with reference to ServiceRequest with id %s is not found.
LIBRARY_EVALUATE_RULE_SYNTAX_ERRORS
: Syntax for rule is invalid. %s
LIBRARY_EVALUATE_OUTPUT_PARAMETER_NOT_SUPPORTED
: Output parameter of type %s is not supported.
LIBRARY_EVALUATE_INPUT_PARAMETER_NOT_SUPPORTED
: Input parameter of type %s is not supported.
LIBRARY_EVALUATE_UNEXPECTED_LIBRARY
: Evaluate is invoked on Library with id %s. This Library is not the expected Library referenced by the ActivityDefinition.
LIBRARY_EVALUATE_UNABLE_TO_RESOLVE_RESOURCE
: Not able to resolve %s when input is of type %s.
LIBRARY_EVALUATE_DURATION_UNIT_CODE_UNKNOWN
: Unsupported code %s for Duration.code. Duration.code should be a valid UCUM code. Supported codes are ('s', 'min', 'h', 'd', 'wk', 'mo', 'a').
LIBRARY_EVALUATE_LOGIC_RULE_INVALID_INPUT
: Error evaluating logic rule. Category: %s, Focus: %s, RuleDescription: %s
LIBRARY_IDENTIFIER_UPDATE_RESTRICTED
: Validation error: attempt to update Library Identifiers list.
LIBRARY_UNKNOWN_IDENTIFIER
: Unable to find unique Library with identifier: %s. Number of search results: %s
LIBRARY_MISSING_IDENTIFIER
: Library %s does not have identifier of type: %s
MEASUREMENT_SEARCHMEASUREMENT_PERIOD_NOT_SPECIFIED
: Period must be specified
MEASUREMENT_SEARCHMEASUREMENT_PATIENT_AND_EPISODE_NOT_SPECIFIED
: At least patient or episodeOfCare must be specified
MEASUREMENT_SEARCHMEASUREMENT_PATIENT_AND_EPISODE_AND_SERVICEREQUEST_NOT_SPECIFIED
: At least one patient, episodeOfCare or serviceRequest must be specified
MEASUREMENT_SEARCHMEASUREMENT_COUNT_NOT_SPECIFIED
: A positive number for Count must be specified
MEASUREMENT_SEARCHMEASUREMENT_COUNT_LIMIT_EXCEEDED
: Count limit of 100 exceeded
MEASUREMENT_SEARCHMEASUREMENT_START_OR_END_NOT_SPECIFIED
: Either start or end must be provided, but none was provided
MEASUREMENT_SEARCHMEASUREMENT_START_AND_END_BOTH_SPECIFIED
: Both start and end cannot be specified
MEASUREMENT_SEARCHMEASUREMENT_UNSUPPORTED_REFERENCE
: Unsupported resource reference, expected %s but was %s
MEASUREMENT_SEARCHMEASUREMENT_UNSUPPORTED_DEVICE_REFERENCE
: Unsupported device reference
MEASUREMENT_SEARCHMEASUREMENT_UNSUPPORTED_BASEDON_REFERENCE
: Unsupported based-on reference: %s
MEASUREMENT_SEARCHMEASUREMENT_REFERENCED_RESOURCE_NOT_FOUND
: Referenced resource not found: %s
MEASUREMENT_SUBMITMEASUREMENT_INVALID_OBSERVATION_CODE
: Observation.code does not match the code of the referenced ServiceRequest with id %s.
MEASUREMENT_SUBMITMEASUREMENT_INVALID_QUESTIONNAIRE_REFERENCE
: Questionnaire reference with id %s is unexpected. Expected questionnaire reference to match questionnaire reference of related ActivityDefinition with id %s.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_SHOULD_REFERENCE_PATIENT
: Input resources of type EHealthObservation, EHealthMedia and EHealthQuestionnaireResponse should reference a patient.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_SHOULD_REFERENCE_EPISODEOFCARE
: Input resources of type EHealthObservation, EHealthMedia and EHealthQuestionnaireResponse should reference an episode of care.
MEASUREMENT_SUBMITMEASUREMENT_EMPTY_INPUT_BUNDLE
: The input bundle does not contain any resources.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_BUNDLE_CONTAINS_NONE_OF_EXPECTED_RESOURCES
: The input bundle does not contain any resources of type EHealthObservation, EHealthMedia, EHealthQuestionnaireResponse.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_BUNDLE_CONTAINS_INVALID_RESOURCES
: The input bundle contains resources which are not of type EHealthObservation, EHealthMedia, EHealthQuestionnaireResponse or EHealthProvenance.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_INVALID_POLICY
: Submitted provenances should use the policy 'Reuse of measurement chosen by citizen'
MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_REFERENCE_MISSING
: EHealthProvenance resource is referencing %s but it is not provided as part of the input.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_NOT_SINGLE_TARGET
: Provenance.target should have exactly one reference.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_TARGET_AND_ENTITY_SHOULD_BE_SAME_TYPE
: Provenance.target and Provenance.entity should be of same type.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_TARGET_AND_ENTITY_SHOULD_REFERENCE_SAME_PATIENT
: Provenance.target and Provenance.entity should reference the same patient
MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_TARGET_AND_ENTITY_SHOULD_USE_SAME_DATE
: Provenance.target and Provenance.entity should use the same date.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_ENTITY_IS_REUSING
: Provenance.entity is reusing another measurement and thus can not be used for reuse.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_INVALID
: %s is invalid.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_NOT_SINGLE_ENTITY
: Provenance.entity should have exactly one reference.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_FOR_DIFFERENT_PATIENTS
: The resources provided are for different patients.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_NOT_PART_OF_SAME_EPISODEOFCARE
: The resources provided are not all part of the same episode of care.
MEASUREMENT_SUBMITMEASUREMENT_PROCEDURE_REQUEST_IS_NOT_ACTIVE
: Procedure request with id:[%s] is not active.
MEASUREMENT_SUBMITMEASUREMENT_ACTIVITYDEFINITION_MISSING_QUESTIONNAIRE_REFERENCE
: ActivityDefinition with id %s does not contain a relatedArtifact with a Questionnaire reference
MEASUREMENT_SUBMITMEASUREMENT_DIFFERENT_PATIENT_REFERENCE
: The patient referenced by the EpisodeOfCare is different than the patient referenced by the provided resources
MEASUREMENT_SUBMITMEASUREMENT_REUSE_NOT_ALLOWED
: Reuse of resource with id %s is not allowed.
MEASUREMENT_SUBMITMEASUREMENT_ASSOCIATED_QUALITY_NOT_PRESENT
: Associated quality %s is not present on submitted resource. Reuse of resource is not allowed.
MEASUREMENT_SUBMITMEASUREMENT_QUALITY_IS_NOT_SUBSUMED
: Quality %s does not subsume %s. Reuse of resource is not allowed.
MEASUREMENT_SUBMITMEASUREMENT_RESOURCE_TO_OLD_TO_BE_USED_FOR_REUSE
: Reuse of resource is not allowed due to the resource being too old.
MEASUREMENT_SUBMITMEASUREMENT_DURATION_UNIT_CODE_UNKNOWN
: Unsupported code %s for Duration.code. Duration.code should be a valid UCUM code. Supported codes are ('s', 'min', 'h', 'd', 'wk', 'mo', 'a').
MEASUREMENT_SUBMITMEASUREMENT_MORE_THAN_ONE_DEVICE_QUALITY
: Only one device quality allowed for each observation/media
MEASUREMENT_SUBMITMEASUREMENT_INVALID_RESOLVED_TIMING
: ResolvedTiming must have either type=Resolved and start/end or type=Unresolved/Adhoc/Extra and no start/end
MEASUREMENT_SUBMITMEASUREMENT_TOO_MANY_ANSWERS
: QuestionnaireResponse: %s has too many answers for the item with linkId: %s
MEASUREMENT_SUBMITMEASUREMENT_TOO_FEW_ANSWERS
: QuestionnaireResponse: %s has too few answers for the item with linkId: %s
MEASUREMENT_GET_DATA_NO_DATA_FOUND
: Encrypted media data with id %s was not found
OBSERVATION_MEDIA_NOT_SUPPORTED_MESSAGE
: Measurement was of media type. This was not translated to an observation since it is not supported in FHIRORGANIZATION_SOURCE_MUST_BE_MANUAL
: The operation can only be performed for Organization with source "manual"
ORGANIZATION_IDENTIFIER_MUST_BE_SSL_WHEN_SOURCE_MANUAL
: The operation can only be performed for SSL Organizations when the source is "manual"
ORGANIZATION_IDENTIFIER_NOT_UNIQUE
: Organization Identifier not unique: %s
ORGANIZATION_IDENTIFIER_SYSTEM_NOT_ALLOWED_FOR_SOURCE_MANUAL
: Identifier system is not allowed for Organization with source "manual"
ORGANIZATION_TRAVERSE_TO_SOR_NOT_POSSIBLE
: No related SOR organization could be found for: %s
ORGANIZATION_IDENTIFIER_MUST_CONTAIN_AT_LEAST_CVR_FOR_SOURCE_MANUAL
: Identifier system CVR required for Organization with source "manual"
ORGANIZATION_UNKNOWN_IDENTIFIER
: Unable to find unique Organization with identifier: %s. Number of search results: %s
ORGANIZATION_MISSING_IDENTIFIER
: Organization %s does not have identifier of type: %s
PLANDEFINITION_UPDATE_ALLOWED_FOR_STATUS
: Update is only allowed for PlanDefinition with status: %s or %s.
PLANDEFINITION_UPDATE_TO_NOT_ALLOWED_STATE
: Update is not allowed for PlanDefinition with %s status to different than %s status.
PLANDEFINITION_VALIDATE_MANDATORY_ACTIVITYDEFINITION_OR_SUBPLAN_REFERENCE
: At least one activity definition or subplan should be referenced.
PLANDEFINITION_VALIDATE_ALL_REFERENCED_ACTIVITYDEFINITIONS_OR_SUBPLANS_SHOULD_BE_ACTIVE
: All referenced activity definitions or subplans should be with state: "active"
PLANDEFINITION_MISSING_RELATED_ACTION
: An action points to a non-existing related action
PROVENANCE_NO_READ_PRIVILEGE
: User must be logged in with the provenance read privilege
PROVENANCE_NO_SEARCH_PRIVILEGE
: User must be logged in with the provenance search privilege
PROVENANCE_SEARCH_DATA_NOT_MATCH_CONTEXT
: The target property should match to the episode of care in context
QFDD_NARRATIVE_MISSING_TEXT_ERROR
: Information section does not have a text element. LinkId: %s
QFDD_NARRATIVE_MISSING_EXTENSION_ERROR
: Information section does not have a rendering-xhtml extension. LinkId: %s
QUESTIONNAIRE_NOT_ALLOWED_TO_UPDATE_IN_STATUS
: Update is not allowed for questionnaires with statuses: %s, %s
QUESTIONNAIRE_NOT_ALLOWED_TO_UPDATE_STATUS
: Update is not allowed for questionnaires with %s status to different than %s status
QUESTIONNAIRE_NOT_ALLOWED_TO_DELETE_WITH_STATUS
: Delete only possible for questionnaires with status: %s
QUESTIONNAIRE_IMAGE_FORMAT_VALIDATION_MESSAGE
:
%s Image in questionnaire item with linkID %s and Binary contentType %s does not match any code in ValueSet: %s
QUESTIONNAIRE_IMAGE_SIZE_VALIDATION_MESSAGE
:
%s Image in questionnaire item with linkID %s exceeds the maximum size of %s kB
QUESTIONNAIRE_QFDD_DOES_NOT_EXIST_IN_DOCUMENT_TRANSFORMATION
: The QFDD with the identifier %s does not exist in document transformation
QUESTIONNAIRE_TERMINOLOGY_HELPER_CODE_NOT_FOUND
: Code %s for CodeSystem %s not found
QUESTIONNAIRE_TERMINOLOGY_HELPER_CODE_SYSTEM_NOT_FOUND
: Code system not found for url: %s
QUESTIONNAIRE_TERMINOLOGY_HELPER_CODE_SYSTEM_FOUND_MORE_THAN_ONE
: Found more than one code system for url: %s
REPORTING_MISSING_INPUT_PARAMETER
: Parameter "%s" is mandatory for report "%s".
REPORTING_REPORT_GENERATION_FAILED
: Report generation has failed
REPORTING_SYNCHRONOUS_GENERATION_NOT_ALLOWED
: Synchronous generation of the report is not allowed
REPORTING_SCHEDULE_NOT_ALLOWED
: Scheduled generation of the report is not allowed
REPORTING_EXECUTE_NOT_ALLOWED
: Asynchronous generation of the report is not allowed
REPORTING_MUTUALLY_EXCLUSIVE_INPUT_PARAMETER
: Parameters "%s" and "%s" are mutually exclusive for report "%s".
SECURITY_TOKEN_CONTEXT_NOT_ALLOWED
: Security token context not allowed: %s
SECURITY_TOKEN_INSUFFICIENT_PERMISSION
: Insufficient permission for %s for %s
SECURITY_USER_NOT_ALLOWED
: Resource not allowed for user: %s
SECURITY_TOKEN_CONTEXT_MISSING
: Security token context missing for user type: %s
SECURITY_TOKEN_CONTEXT_MISSING_CONTEXT
: Security token context missing for context type: %s
SECURITY_RESOURCE_NOT_MATCHING_TOKEN_CONTEXT
: Resource not matching security token context: %s
SECURITY_OPERATION_NOT_ALLOWED_FOR_USER_TYPE
: Operation not allowed for user type: %s
SECURITY_SEARCH_PARAM_NOT_MATCHING_TOKEN_CONTEXT
: Search parameters not matching security token context: %s
SECURITY_SEARCH_PARAMS_MANDATORY
: Search parameters mandatory with current user type and combination of search parameters: %s
SECURITY_SEARCH_OPERATION_POST_CONSTRAINT
: Search on %s only supports POST style.
STATUS_SCHEDULE_PAUSE_MAX_30_DAYS
: A scheduled pause may not last more than 30 days
STATUS_SCHEDULE_IDENTICAL_TIME
: Multiple status changes may not be scheduled to be activated simultaneously
SYSTEM_TAG_UNEXPECTED_TAG
: Resource contains system tag(s), which do not match related resource.TASK_INVESTIGATION_ITEM_REFERENCES_MUST_HAVE_VERSION_AND_VERSIONLESS
: Investigation references must have an item with version and one versionless
TASK_RESTRICTION_CATEGORY_NONE_CANT_BE_COMBINED
: Restriction category 'None' can't be combined with others
TASK_RESTRICTION_CATEGORY_NOT_MATCHING_TOKEN_CONTEXT
: Restriction category '%s' does not match token context
TASK_MEASUREMENT_PROCESSING_FAILED
: Measurement processing failed for Provenance %s
TASK_AUTOMATED_PROCESSING_RESOURCE_HANDLER_INVALID_JSON
: Unable to parse json string: %s.
TASK_AUTOMATED_PROCESSING_INVALID_INPUT_RESOURCE
: Resource of type %s is not a valid input resource.
TASK_AUTOMATED_PROCESSING_MISSING_MEASUREMENT_PROCEDURE_REQUEST
: Could not determine if measurement is missing for procedure request: %s.
TASK_AUTOMATED_PROCESSING_FAILING_REQUESTS_JOB_TERMINATED
: Limit of %s consecutive failing requests is reached. Scheduled audit job is terminated.
TASK_AUTOMATED_PROCESSING_CAREPLAN_NOT_FOUND
: CarePlan is not found when searching by activity: %s.
TASK_AUTOMATED_PROCESSING_RULE_OUTPUT_NOT_FOUND
: RuleOutput not found when searching through Task Automated Processing Resource
TASK_FOR_NOT_SET
: When episode of care is set, the field 'for' must reference the corresponding patient
TRANSFORMATION_DEPRECATE_DOCUMENT_CPR_DIDNT_MATCH
: Found document didn't match with CPR
TRANSFORMATION_DEPRECATE_DOCUMENT_MORE_THAN_ONE_FOUND
: More than 1 DocumentReference with same master identifier found. The master identifier should be unique.
TRANSFORMATION_DEPRECATE_DOCUMENT_NO_DOCUMENT_FOUND
: No matching document found
TRANSFORMATION_QFDD_UNKNOWN_QUESTION_TYPE
: Unknown QFDD question type. Question id: %s
TRANSFORMATION_QFDD_UNSUPPORTED_STRUCTURE
: The root item structure was neither an Information Only Section nor a Question Section. LinkId: %s
TRANSFORMATION_QFDD_XML_MISSING
: Invalid input document reference, it must contain content with data of QFDD xml
TRANSFORMATION_QFDD_ITEM_WITH_SLIDER_MISSING_STEPVALUE
: Questionnaire item with linkId '%s' has itemControl: 'slider' but has no step value extension.
TRANSFORMATION_QFDD_ITEM_WITH_SLIDER_NOT_MATCHING_DISCRETE_SLIDER
: Questionnaire item with linkId '%s' has itemControl: 'slider' but either repeats if true. Was: %s. or maxOccursValue is larger than 1. Was: %s.
TRANSFORMATION_QFDD_CODESYSTEM_TITLE_MISSING
: CodeSystem title is missing, for CodeSystem with url: %s
TRANSFORMATION_QFDD_QUESTION_NARRATIVE_FILE_TEMPLATE_ERROR
: Template for question section narrative can't be found or written.
TRANSFORMATION_QFDD_QUESTION_NARRATIVE_TEMPLATE_SYNTAX_ERROR
: Could not process template for question section narrative due to syntax errors or missing variables
TRANSFORMATION_QRD_INVALID_INPUT_PARAMETERS
: Input bundle should contain just one EHealthComposition, EHealthQuestionnaireResponse, EHealthQuestionnaire and DocumentReference(QFDD).
TRANSFORMATION_FROM_QRD_INVALID_INPUT_PARAMETERS
: Input bundle should contain just one EHealthQuestionnaire and DocumentReference(QRD).
TRANSFORMATION_FROM_QRD_DUPLICATED_EXTERNAL_IDENTIFIER
: Cannot transform from QRD to QuestionnaireResponse. Duplicated external identifiers: %s.
TRANSFORMATION_FROM_QRD_EXTERNAL_DOCUMENT_NOT_MATCHING_QFDD_IDENTIFIER_ON_QUESTIONNAIRE
: External Document reference in QRD does not match QFDD identifier on Questionnaire. External Document reference: '%s'. QFDD identifier on Questionnaire: '%s'.
TRANSFORMATION_FROM_QRD_NO_EXTERNAL_DOCUMENT_FOUND_IN_QRD
: No External Document reference found in QRD.
TRANSFORMATION_FROM_QRD_NO_QFDD_IDENTIFIER_ON_QUESTIONNAIRE
: Questionnaire does not have a QFDD identifier. No identifier with system starting with 'urn:oid'.
TRANSFORMATION_FROM_QRD_COULD_NOT_FIND_PARENT_FOR_LINK_ID
: Could not find parent for item with linkId: %s.
TRANSFORMATION_FROM_QRD_QRD_HAS_NO_SECTIONS
: QRD has no sections with questions.
TRANSFORMATION_FROM_QRD_QRD_QUESTION_TYPE_DOES_NOT_MATCH_QUESTIONNAIRE_ITEM_TYPE
: QRD Question type '%s' does not match questionnaire item type '%s'. LinkId: %s.
TRANSFORMATION_QRD_UNSUPPORTED_QUESTION_TYPE
: Unsupported Questionnaire type: %s.
TRANSFORMATION_QRD_INVALID_NUMBER_OF_ANSWERS
: QuestionnaireResponse item should contain from %s to %s answers.
TRANSFORMATION_QRD_SLIDER_MISMATCH_BETWEEN_TYPE_AND_SLIDER_STEP
: Questionnaire item with linkId '%s' has itemControl: 'slider' and item.type: 'Integer' but has decimal step value: %s.
TRANSFORMATION_QRD_INVALID_SLIDER_EXTENSIONS
: Questionnaire item with linkId '%s' has itemControl: 'slider', therefore it must contain at least the following extensions: %s.
TRANSFORMATION_QRD_NO_SLIDER_STEP_EXTENSION
: Questionnaire item with linkId '%s' has itemControl: 'slider', therefore it must contain one of the following extensions: %s.
TRANSFORMATION_QRD_NO_SLIDER_ITEM_CONTROL_EXTENSION
: Questionnaire item with linkId '%s' has no itemControl extension with code: 'slider'.
TRANSFORMATION_QRD_MISSING_IDENTIFIER
: Identifier on composition is mandatory
TRANSFORMATION_QRD_XML_MISSING
: Invalid input document reference, it must contain content with data of QRD xml
TRANSFORMATION_QRD_EXPECTING_DISPLAY_ITEM_FOR_INFO_SECTION
: QFDD section with title '%s' has no organizers(Information Only Section). Expecting FHIR Questionnaire root group to have exactly one item of display. Found %s items.
TRANSFORMATION_QRD_EXPECTING_DISPLAY_ITEM_FOR_INFO_SECTION_FOUND_OTHER_TYPE
: QFDD section with title '%s' has no organizers(Information Only Section). Expecting FHIR Questionnaire root group to contain exactly one item of type 'display'. Found item of type: '%s'.
TRANSFORMATION_QRD_NUMBER_OF_ITEMS_IN_ROOT_GROUP_DOES_NOT_MATCH_NUMBER_OF_ORGANIZERS
: QFDD section with title '%s' has %s organizers. Expect FHIR Questionnaire root group to contain the same number of items with type 'group'. Found: %s.
TRANSFORMATION_QRD_EXPECTING_ONLY_SUB_GROUPS_IN_ROOT_GROUP
: QFDD section with title '%s' has %s organizers. Expect FHIR Questionnaire root group to contain only items of type: 'group'.
TRANSFORMATION_QRD_EXPECTING_ROOT_ITEM_TO_BE_OF_TYPE_GROUP
: Root item on questionnaire is not of type 'group'. Type was: %s
TRANSFORMATION_QRD_EXPECTING_ITEM_TO_BE_OF_TYPE_GROUP
: Item is not of type group. Type: %s
TRANSFORMATION_QRD_NUMBER_OF_ITEMS_ON_ROOT_LEVEL_DOES_NOT_MATCH_NUMBER_OF_SECTIONS
: The number of root items on questionnaire does not match the number of QFDD sections. Questionnaire: %s.
TRANSFORMATION_QRD_FOUND_MORE_THAN_ONE_MATCH_FOR_LINKID_IN_QUESTIONNAIRE_RESPONSE
: Found more than 1 match for LinkId in QuestionnaireResponse. LinkId: %s.
TRANSFORMATION_QRD_NO_MATCH_FOR_ASSOCIATED_TEXT_QUESTION_IN_QUESTIONNAIRE_RESPONSE
: Found no match for associatedTextQuestion in QuestionnaireResponse. Found Questionnaire item with linkId: %s.
TRANSFORMATION_QRD_EXPECTING_QUESTIONNAIRE_TIEM_TO_HAVE_EXTERNAL_IDENTIFIER
: Expected questionnaireItem to have externalIdentifier: %s. But was: %s
TRANSFORMATION_QRD_FOUND_NO_QUESTIONNAIRE_RESPONSE_FOR_ASSOCIATED_TEST_QUESTION
: Found no QuestionnaireResponse for associatedTextQuestion. Found Questionnaire item with linkId: %s.
TRANSFORMATION_QRD_PRECONDITION_DO_NOT_MATCH_THE_QUESTION_FOR_ASSOCIATED_TEXT_QUESTION
: The precondition criterion code does not match the expected question code. Expected: %s. But was: %s
TRANSFORMATION_QRD_MULTIPLE_CHOICE_ANSWER_EXPECTING_CODING_TYPE_FOR_VALUE
: Expecting answer value to be of type Coding. QuestionResponseItem with linkId: %s.
TRANSFORMATION_QRD_PRECONDITION_GROUP_GROUP_TYPE_UNKNOWN
: Unknown GroupType: %s
TRANSFORMATION_QRD_PRECONDITION_MORE_THAN_ONE
: Transformation do not support more than one precondition for associatedTextQuestion. Found %s. AssociatedTextQuestion: %s
TRANSFORMATION_QRD_EXPECT_IMAGE_IN_QUESTIONNAIRE_ITEM
: Expecting QuestionnaireItem to have an image as the corresponding QFDD question has an image. Question id: %s
TRANSFORMATION_QRD_NOT_EXPECTING_IMAGE_IN_QUESTIONNAIRE_ITEM
: Not expecting QuestionnaireItem to have an image as the corresponding QFDD question do not have an image. Question id: %s
TRANSFORMATION_QRD_UNKNOWN_QRD_RESPONSE_TYPE
: Unknown QRD response type. QRD Question id: %s
TRANSFORMATION_QRD_ASSOCIATED_TEXT_QUESTION_ITEM_NOT_OF_TYPE_TEXT
: AssociatedTextQuestion item with id: '%s' is not of type 'text'. Type was: %s
TRANSFORMATION_QRD_QFDD_QUESTION_DOES_NOT_SUPPORT_ASSOCIATED_TEXT_QUESTION
: QFDDQuestion with id: '%s' does not support associatedText. Class was: %s
TRANSFORMATION_PHMR_MISSING_RESOURCE
: Input bundle missing resource: %s
TRANSFORMATION_PHMR_NARRATIVE_ERROR
: Can't generate narrative for: %s
TRANSFORMATION_HEADER_MISSING_CPR
: CPR is mandatory for patient but not present in fhir bundle
TRANSFORMATION_PHMR_INVALID_OBSERVATION_CODING
: Observation coding system must be urn:oid:1.2.208.176.2.1
TRANSFORMATION_PHMR_INVALID_OBSERVATION_COMMENT_AUTHOR_REFERENCE
: The author of a measurement comment is a reference not provided in the bundle.
TRANSFORMATION_PHMR_INVALID_OBSERVATION_RANGES_CODING
: Observation.observationRanges[x].type.coding.system should be http://www.example.com/medcom/message-codes
TRANSFORMATION_PHMR_INVALID_OBSERVATION_RANGES_RAL
: RAL observation ranges should not have both High and Low set when transforming to PHRM, but High is: %s, and Low is: %s
TRANSFORMATION_PHMR_INVALID_OBSERVATION_RANGES_GAL
: GAL observation ranges should not have both High and Low set when transforming to PHRM, unless either bound is replaced with a RAL reference range, but High is: %s, and Low is: %s
TRANSFORMATION_PHMR_INVALID_NUMBER_OF_DECIMALS
: Value should have no more than 7 decimals, but is: %s
TRANSFORMATION_PHMR_OBSERVATION_QUANTITY_MISSING
: Value should be Quantity type and not null
TRANSFORMATION_PHMR_XML_MISSING
: Invalid input document reference, it must contain content with data of PHMR xml
TRANSFORMATION_PHMR_ID_OID_NOT_FOUND
: NamingSystem or CodeSystem with url %s is not found.
TRANSFORMATION_PHMR_MISSING_MEASUREMENT_IDENTIFIER
: No identifier found for measurement
TRANSFORMATION_PHMR_DOCUMENT_TIME_INTERVAL_MISSING
: Document is missing serviceStartTime and serviceStopTime.
TRANSFORMATION_PHMR_DOCUMENT_INVALID_EFFECTIVE
: Invalid Observation.effective, expecting DateTime, Period or Instant
TRANSFORMATION_PHMR_MEASUREMENT_INVALID_METHOD_CODES
: Method codes for performerType and provisionMethod for observation with id '%s' could not be established.
TRANSFORMATION_PHMR_MEASUREMENT_TOO_MANY_DECIMALS
: Could not transform measurement with reference range Low: %s and High: %s since we cannot correctly translate more than 7 decimals.
TRANSFORMATION_HEADER_MISSING_CONFIDENTIALITY_CODE
: Composition.confidentiality is mandatory
TRANSFORMATION_HEADER_WRONG_TYPE_COMPOSITION_SUBJECT
: Composition.subject should be a Patient
TRANSFORMATION_HEADER_MISSING_CUSTODIAN
: Custodian is mandatory for transformation
TRANSFORMATION_HEADER_MISSING_COMPOSITION
: Composition expected for transformation is not found
TRANSFORMATION_HEADER_MISSING_ATTESTER
: Composition.attester.party is mandatory for transformation
TRANSFORMATION_HEADER_WRONG_TYPE_COMPOSITION_AUTHOR
: Composition.author should either be a Patient or Practitioner
TRANSFORMATION_HEADER_MISSING_COMPOSITION_AUTHOR_ORGANIZATION
: Composition.authorOrganization is mandatory for transformation
TRANSFORMATION_HEADER_AUTHOR_ORGANIZATION_MUST_CONTAIN_SOR_ID
: Composition.authorOrganization must contain SOR identifier: %s
TRANSFORMATION_HEADER_ATTESTER_ORGANIZATION_MUST_CONTAIN_SOR_ID
: Composition.attester.party must contain SOR identifier: %s
TRANSFORMATION_HEADER_CUSTODIAN_MUST_CONTAIN_SOR_ID
: Custodian organization must contain SOR identifier: %s
TRANSFORMATION_HEADER_COMPOSITION_HAS_NO_TIMEZONE_OR_SECONDS
: Composition has no timezone or seconds set: %s
TRANSFORMATION_XDS_PROPERTY_MISSING_EXCEPTION
: '%s' is missing which is required for document sharing. DocumentReference id: '%s'.
TRANSFORMATION_XDS_PROPERTY_CODE_INVALID_EXCEPTION
: '%s' is required for document sharing but the specified coding is not valid for the valueSet '%s': system=%s, code=%s, display=%s. DocumentReference id: '%s'
TRANSFORMATION_FROM_XHTML_TO_CDA_XML_FAILED
: Unable to transform XHTML to CDA XML format
TRANSFORMATION_FROM_CDA_XML_TO_XHTML_FAILED
: Unable to tranform CDA XML to XHTML format
TRANSFORMATION_XSLT_CONFIGURATION_ERROR
: Error creating XLST transformer: %s
TRANSFORMATION_XSD_CONFIGURATION_ERROR
: Error creating XSD transformer: %s
TRANSFORMATION_APD_XML_MISSING
: Invalid input document reference, it must contain content with data of APD xml
UPLOAD_QFDD_MASTERIDENTIFIER_IS_ALREADY_IN_USE
: The masterIdentifier on the DocumentReference is not unique
UPLOAD_QFDD_THE_ID_OF_THE_DOCUMENT_IS_NULL
: Missing Id in the QFDD.
VERSIONING_RESOURCE_MUST_BE_FROM_CURRENT_ENVIRONMENT
: Versioning validation error: Resource must be from current environment: %s.
VERSIONING_MULTIPLE_DRAFTS_IN_BASE_NOT_ALLOWED
: Versioning validation error: Only one draft resource at a time is allowed per base.
VERSIONING_RESOURCE_NOT_ELIGIBLE_FOR_CLONE
: Versioning validation error: A resource must have base-identifier, environment-identifier, versioning-identifier and version to be cloned.
VERSIONING_REFERENCE_NOT_RELEVANT_FOR_RESOURCE
: Versioning validation error: References included in deep_clone_references must be present in resource to clone, %s: %s.
VERSIONING_REFERENCE_MISSING_IN_TREE_PATH
: Versioning validation error: The following resources could not be cloned since their parent resource, %s, is not present in deep_clone_refernces: %s.