eHealth Infrastructure
3.3.0 - ci-build Denmark flag

eHealth Infrastructure, published by Den telemedicinske infrastruktur (eHealth Infrastructure). This guide is not an authorized publication; it is the continuous build for version 3.3.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/fut-infrastructure/implementation-guide/ and changes regularly. See the Directory of published versions

Resource Profile: ehealth-devicemetric - Detailed Descriptions

Active as of 2024-12-20

Definitions for the ehealth-devicemetric resource profile.

Guidance on how to interpret the contents of this table can be found here

0. DeviceMetric
2. DeviceMetric.extension
Control4..?
SlicingThis element introduces a set of slices on DeviceMetric.extension. The slices areUnordered and Open, and can be differentiated using the following discriminators:
  • value @ url
  • 4. DeviceMetric.extension:properties
    Slice Nameproperties
    Control0..*
    TypeExtension(Properties) (Complex Extension)
    6. DeviceMetric.extension:qualities
    Slice Namequalities
    Control1..1
    TypeExtension(Qualities) (Complex Extension)
    8. DeviceMetric.extension:qualitiyHistory
    Slice NamequalitiyHistory
    Control0..*
    TypeExtension(Quality history) (Complex Extension)
    10. DeviceMetric.extension:templateQualities
    Slice NametemplateQualities
    Control3..3
    TypeExtension(Template qualities) (Complex Extension)
    12. DeviceMetric.type
    BindingThe codes SHALL be taken from Device Measurement Unit
    (required to http://ehealth.sundhed.dk/vs/device-measurement-unit)
    14. DeviceMetric.unit
    BindingThe codes SHALL be taken from Device Measurement Unit
    (required to http://ehealth.sundhed.dk/vs/device-measurement-unit)
    16. DeviceMetric.source
    Control1..?
    TypeReference(ehealth-device)referenced
    18. DeviceMetric.parent
    Control0..0
    20. DeviceMetric.calibration
    22. DeviceMetric.calibration.extension
    SlicingThis element introduces a set of slices on DeviceMetric.calibration.extension. The slices areUnordered and Open, and can be differentiated using the following discriminators:
    • value @ url
    • 24. DeviceMetric.calibration.extension:calibrationExpires
      Slice NamecalibrationExpires
      Control0..1
      TypeExtension(Calibration expires) (Extension Type: dateTime)

      Guidance on how to interpret the contents of this table can be found here

      0. DeviceMetric
      Definition

      Describes a measurement, calculation or setting capability of a medical device.

      ShortMeasurement, calculation or setting capability of a medical device
      Comments

      For the initial scope, this DeviceMetric resource is only applicable to describe a single metric node in the containment tree that is produced by the context scanner in any medical device that implements or derives from the ISO/IEEE 11073 standard.

      Control0..*
      Is Modifierfalse
      Summaryfalse
      Invariantsdom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty())
      dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty())
      dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty())
      dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty())
      dom-6: A resource should have narrative for robust management (text.`div`.exists())
      2. DeviceMetric.implicitRules
      Definition

      A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc.

      ShortA set of rules under which this content was created
      Comments

      Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc.

      Control0..1
      Typeuri
      Is Modifiertrue because This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies it's meaning or interpretation
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Summarytrue
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      4. DeviceMetric.extension
      Definition

      An Extension


      May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

      ShortExtensionAdditional content defined by implementations
      Comments

      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

      Control40..*
      TypeExtension
      Is Modifierfalse
      Summaryfalse
      Alternate Namesextensions, user content
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
      SlicingThis element introduces a set of slices on DeviceMetric.extension. The slices areUnordered and Open, and can be differentiated using the following discriminators:
      • value @ url
      • 6. DeviceMetric.extension:properties
        Slice Nameproperties
        Definition

        Properties of this device. Properties are static by nature whereas qualities are dynamic and may change during the life cycle or calibration cycle of a device.

        ShortProperties of the Device
        Control0..*
        This element is affected by the following invariants: ele-1
        TypeExtension(Properties) (Complex Extension)
        Is Modifierfalse
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        8. DeviceMetric.extension:qualities
        Slice Namequalities
        Definition

        Current device quality

        ShortQualities of the Device
        Control1..1
        This element is affected by the following invariants: ele-1
        TypeExtension(Qualities) (Complex Extension)
        Is Modifierfalse
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        10. DeviceMetric.extension:qualitiyHistory
        Slice NamequalitiyHistory
        Definition

        History of device quality

        ShortHistory of device quality
        Control0..*
        This element is affected by the following invariants: ele-1
        TypeExtension(Quality history) (Complex Extension)
        Is Modifierfalse
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        12. DeviceMetric.extension:templateQualities
        Slice NametemplateQualities
        Definition

        Device quality default settings for an initial, a degraded, and an overridden device quality.

        ShortDevice quality default settings
        Control3..3
        This element is affected by the following invariants: ele-1
        TypeExtension(Template qualities) (Complex Extension)
        Is Modifierfalse
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        14. DeviceMetric.modifierExtension
        Definition

        May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        ShortExtensions that cannot be ignored
        Comments

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Control0..*
        TypeExtension
        Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the resource that contains them
        Summaryfalse
        Requirements

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Alternate Namesextensions, user content
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        16. DeviceMetric.type
        Definition

        Describes the type of the metric. For example: Heart Rate, PEEP Setting, etc.

        ShortIdentity of metric, for example Heart Rate or PEEP Setting
        Comments

        DeviceMetric.type can be referred to either IEEE 11073-10101 or LOINC.

        Control1..1
        BindingThe codes SHALL be taken from The codes SHOULD be taken from Device Measurement Unithttp://hl7.org/fhir/ValueSet/devicemetric-type
        (required to http://ehealth.sundhed.dk/vs/device-measurement-unit)
        TypeCodeableConcept
        Is Modifierfalse
        Summarytrue
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        18. DeviceMetric.unit
        Definition

        Describes the unit that an observed value determined for this metric will have. For example: Percent, Seconds, etc.

        ShortUnit of Measure for the Metric
        Comments

        DeviceMetric.unit can refer to either UCUM or preferable a RTMMS coding system.

        Control0..1
        BindingThe codes SHALL be taken from The codes SHOULD be taken from Device Measurement Unithttp://hl7.org/fhir/ValueSet/devicemetric-type
        (required to http://ehealth.sundhed.dk/vs/device-measurement-unit)
        TypeCodeableConcept
        Is Modifierfalse
        Summarytrue
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        20. DeviceMetric.source
        Definition

        Describes the link to the Device that this DeviceMetric belongs to and that contains administrative device information such as manufacturer, serial number, etc.

        ShortDescribes the link to the source Device
        Control10..1
        TypeReference(ehealth-device, Device)referenced
        Is Modifierfalse
        Summarytrue
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        22. DeviceMetric.parent
        Definition

        Describes the link to the Device that this DeviceMetric belongs to and that provide information about the location of this DeviceMetric in the containment structure of the parent Device. An example would be a Device that represents a Channel. This reference can be used by a client application to distinguish DeviceMetrics that have the same type, but should be interpreted based on their containment location.

        ShortDescribes the link to the parent Device
        Control0..01
        TypeReference(Device)
        Is Modifierfalse
        Summarytrue
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        24. DeviceMetric.category
        Definition

        Indicates the category of the observation generation process. A DeviceMetric can be for example a setting, measurement, or calculation.

        Shortmeasurement | setting | calculation | unspecified
        Control1..1
        BindingThe codes SHALL be taken from DeviceMetricCategoryhttp://hl7.org/fhir/ValueSet/metric-category|4.0.1
        (required to http://hl7.org/fhir/ValueSet/metric-category|4.0.1)

        Describes the category of the metric.

        Typecode
        Is Modifierfalse
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Summarytrue
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))

        Guidance on how to interpret the contents of this table can be found here

        0. DeviceMetric
        Definition

        Describes a measurement, calculation or setting capability of a medical device.

        ShortMeasurement, calculation or setting capability of a medical device
        Comments

        For the initial scope, this DeviceMetric resource is only applicable to describe a single metric node in the containment tree that is produced by the context scanner in any medical device that implements or derives from the ISO/IEEE 11073 standard.

        Control0..*
        Is Modifierfalse
        Summaryfalse
        Invariantsdom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty())
        dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty())
        dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty())
        dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty())
        dom-6: A resource should have narrative for robust management (text.`div`.exists())
        2. DeviceMetric.id
        Definition

        The logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes.

        ShortLogical id of this artifact
        Comments

        The only time that a resource does not have an id is when it is being submitted to the server using a create operation.

        Control0..1
        Typeid
        Is Modifierfalse
        Summarytrue
        4. DeviceMetric.meta
        Definition

        The metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource.

        ShortMetadata about the resource
        Control0..1
        TypeMeta
        Is Modifierfalse
        Summarytrue
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        6. DeviceMetric.implicitRules
        Definition

        A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc.

        ShortA set of rules under which this content was created
        Comments

        Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc.

        Control0..1
        Typeuri
        Is Modifiertrue because This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies it's meaning or interpretation
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Summarytrue
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        8. DeviceMetric.language
        Definition

        The base language in which the resource is written.

        ShortLanguage of the resource content
        Comments

        Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute).

        Control0..1
        BindingThe codes SHOULD be taken from CommonLanguages
        (preferred to http://hl7.org/fhir/ValueSet/languages)

        A human language.

        Additional BindingsPurpose
        AllLanguagesMax Binding
        Typecode
        Is Modifierfalse
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Summaryfalse
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        10. DeviceMetric.text
        Definition

        A human-readable narrative that contains a summary of the resource and can be used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Resource definitions may define what content should be represented in the narrative to ensure clinical safety.

        ShortText summary of the resource, for human interpretation
        Comments

        Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later.

        Control0..1
        TypeNarrative
        Is Modifierfalse
        Summaryfalse
        Alternate Namesnarrative, html, xhtml, display
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        12. DeviceMetric.contained
        Definition

        These resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, and nor can they have their own independent transaction scope.

        ShortContained, inline Resources
        Comments

        This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels.

        Control0..*
        TypeResource
        Is Modifierfalse
        Summaryfalse
        Alternate Namesinline resources, anonymous resources, contained resources
        14. DeviceMetric.extension
        Definition

        An Extension

        ShortExtension
        Control4..*
        TypeExtension
        Is Modifierfalse
        Summaryfalse
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        SlicingThis element introduces a set of slices on DeviceMetric.extension. The slices areUnordered and Open, and can be differentiated using the following discriminators:
        • value @ url
        • 16. DeviceMetric.extension:properties
          Slice Nameproperties
          Definition

          Properties of this device. Properties are static by nature whereas qualities are dynamic and may change during the life cycle or calibration cycle of a device.

          ShortProperties of the Device
          Control0..*
          This element is affected by the following invariants: ele-1
          TypeExtension(Properties) (Complex Extension)
          Is Modifierfalse
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
          18. DeviceMetric.extension:qualities
          Slice Namequalities
          Definition

          Current device quality

          ShortQualities of the Device
          Control1..1
          This element is affected by the following invariants: ele-1
          TypeExtension(Qualities) (Complex Extension)
          Is Modifierfalse
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
          20. DeviceMetric.extension:qualitiyHistory
          Slice NamequalitiyHistory
          Definition

          History of device quality

          ShortHistory of device quality
          Control0..*
          This element is affected by the following invariants: ele-1
          TypeExtension(Quality history) (Complex Extension)
          Is Modifierfalse
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
          22. DeviceMetric.extension:templateQualities
          Slice NametemplateQualities
          Definition

          Device quality default settings for an initial, a degraded, and an overridden device quality.

          ShortDevice quality default settings
          Control3..3
          This element is affected by the following invariants: ele-1
          TypeExtension(Template qualities) (Complex Extension)
          Is Modifierfalse
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
          24. DeviceMetric.modifierExtension
          Definition

          May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

          Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

          ShortExtensions that cannot be ignored
          Comments

          There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

          Control0..*
          TypeExtension
          Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the resource that contains them
          Summaryfalse
          Requirements

          Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

          Alternate Namesextensions, user content
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
          26. DeviceMetric.identifier
          Definition

          Unique instance identifiers assigned to a device by the device or gateway software, manufacturers, other organizations or owners. For example: handle ID.

          ShortInstance identifier
          Comments

          For identifiers assigned to a device by the device or gateway software, the system element of the identifier should be set to the unique identifier of the device.

          NoteThis is a business identifier, not a resource identifier (see discussion)
          Control0..*
          TypeIdentifier
          Is Modifierfalse
          Summarytrue
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          28. DeviceMetric.type
          Definition

          Describes the type of the metric. For example: Heart Rate, PEEP Setting, etc.

          ShortIdentity of metric, for example Heart Rate or PEEP Setting
          Comments

          DeviceMetric.type can be referred to either IEEE 11073-10101 or LOINC.

          Control1..1
          BindingThe codes SHALL be taken from Device Measurement Unit
          (required to http://ehealth.sundhed.dk/vs/device-measurement-unit)
          TypeCodeableConcept
          Is Modifierfalse
          Summarytrue
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          30. DeviceMetric.unit
          Definition

          Describes the unit that an observed value determined for this metric will have. For example: Percent, Seconds, etc.

          ShortUnit of Measure for the Metric
          Comments

          DeviceMetric.unit can refer to either UCUM or preferable a RTMMS coding system.

          Control0..1
          BindingThe codes SHALL be taken from Device Measurement Unit
          (required to http://ehealth.sundhed.dk/vs/device-measurement-unit)
          TypeCodeableConcept
          Is Modifierfalse
          Summarytrue
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          32. DeviceMetric.source
          Definition

          Describes the link to the Device that this DeviceMetric belongs to and that contains administrative device information such as manufacturer, serial number, etc.

          ShortDescribes the link to the source Device
          Control1..1
          TypeReference(ehealth-device)referenced
          Is Modifierfalse
          Summarytrue
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          34. DeviceMetric.parent
          Definition

          Describes the link to the Device that this DeviceMetric belongs to and that provide information about the location of this DeviceMetric in the containment structure of the parent Device. An example would be a Device that represents a Channel. This reference can be used by a client application to distinguish DeviceMetrics that have the same type, but should be interpreted based on their containment location.

          ShortDescribes the link to the parent Device
          Control0..0
          TypeReference(Device)
          Is Modifierfalse
          Summarytrue
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          36. DeviceMetric.operationalStatus
          Definition

          Indicates current operational state of the device. For example: On, Off, Standby, etc.

          Shorton | off | standby | entered-in-error
          Control0..1
          BindingThe codes SHALL be taken from DeviceMetricOperationalStatus
          (required to http://hl7.org/fhir/ValueSet/metric-operational-status|4.0.1)

          Describes the operational status of the DeviceMetric.

          Typecode
          Is Modifierfalse
          Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
          Summarytrue
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          38. DeviceMetric.color
          Definition

          Describes the color representation for the metric. This is often used to aid clinicians to track and identify parameter types by color. In practice, consider a Patient Monitor that has ECG/HR and Pleth for example; the parameters are displayed in different characteristic colors, such as HR-blue, BP-green, and PR and SpO2- magenta.

          Shortblack | red | green | yellow | blue | magenta | cyan | white
          Control0..1
          BindingThe codes SHALL be taken from DeviceMetricColor
          (required to http://hl7.org/fhir/ValueSet/metric-color|4.0.1)

          Describes the typical color of representation.

          Typecode
          Is Modifierfalse
          Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
          Summarytrue
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          40. DeviceMetric.category
          Definition

          Indicates the category of the observation generation process. A DeviceMetric can be for example a setting, measurement, or calculation.

          Shortmeasurement | setting | calculation | unspecified
          Control1..1
          BindingThe codes SHALL be taken from DeviceMetricCategory
          (required to http://hl7.org/fhir/ValueSet/metric-category|4.0.1)

          Describes the category of the metric.

          Typecode
          Is Modifierfalse
          Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
          Summarytrue
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          42. DeviceMetric.measurementPeriod
          Definition

          Describes the measurement repetition time. This is not necessarily the same as the update period. The measurement repetition time can range from milliseconds up to hours. An example for a measurement repetition time in the range of milliseconds is the sampling rate of an ECG. An example for a measurement repetition time in the range of hours is a NIBP that is triggered automatically every hour. The update period may be different than the measurement repetition time, if the device does not update the published observed value with the same frequency as it was measured.

          ShortDescribes the measurement repetition time
          Control0..1
          TypeTiming
          Is Modifierfalse
          Summarytrue
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          44. DeviceMetric.calibration
          Definition

          Describes the calibrations that have been performed or that are required to be performed.

          ShortDescribes the calibrations that have been performed or that are required to be performed
          Control0..*
          TypeBackboneElement
          Is Modifierfalse
          Summarytrue
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          46. DeviceMetric.calibration.id
          Definition

          Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

          ShortUnique id for inter-element referencing
          Control0..1
          Typestring
          Is Modifierfalse
          XML FormatIn the XML format, this property is represented as an attribute.
          Summaryfalse
          48. DeviceMetric.calibration.extension
          Definition

          An Extension

          ShortExtension
          Control0..*
          TypeExtension
          Is Modifierfalse
          Summaryfalse
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
          SlicingThis element introduces a set of slices on DeviceMetric.calibration.extension. The slices areUnordered and Open, and can be differentiated using the following discriminators:
          • value @ url
          • 50. DeviceMetric.calibration.extension:calibrationExpires
            Slice NamecalibrationExpires
            Definition

            Date when the current calibration expires and recalibration is required.

            ShortDate when the current calibration expires.
            Control0..1
            This element is affected by the following invariants: ele-1
            TypeExtension(Calibration expires) (Extension Type: dateTime)
            Is Modifierfalse
            Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
            ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
            52. DeviceMetric.calibration.modifierExtension
            Definition

            May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

            Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

            ShortExtensions that cannot be ignored even if unrecognized
            Comments

            There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

            Control0..*
            TypeExtension
            Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
            Summarytrue
            Requirements

            Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

            Alternate Namesextensions, user content, modifiers
            Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
            ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
            54. DeviceMetric.calibration.type
            Definition

            Describes the type of the calibration method.

            Shortunspecified | offset | gain | two-point
            Control0..1
            BindingThe codes SHALL be taken from DeviceMetricCalibrationType
            (required to http://hl7.org/fhir/ValueSet/metric-calibration-type|4.0.1)

            Describes the type of a metric calibration.

            Typecode
            Is Modifierfalse
            Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
            Summarytrue
            Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
            56. DeviceMetric.calibration.state
            Definition

            Describes the state of the calibration.

            Shortnot-calibrated | calibration-required | calibrated | unspecified
            Control0..1
            BindingThe codes SHALL be taken from DeviceMetricCalibrationState
            (required to http://hl7.org/fhir/ValueSet/metric-calibration-state|4.0.1)

            Describes the state of a metric calibration.

            Typecode
            Is Modifierfalse
            Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
            Summarytrue
            Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
            58. DeviceMetric.calibration.time
            Definition

            Describes the time last calibration has been performed.

            ShortDescribes the time last calibration has been performed
            Control0..1
            Typeinstant
            Is Modifierfalse
            Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
            Summarytrue