Vital Signs Cross-Country Cross-Language Cross-Paradigm (Demo) IG
0.5.4 - ci-build
Vital Signs Cross-Country Cross-Language Cross-Paradigm (Demo) IG, published by FO. This guide is not an authorized publication; it is the continuous build for version 0.5.4 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/frankoemig/vital-signs-demo/ and changes regularly. See the Directory of published versions
Active as of 2024-04-16 |
Definitions for the BloodPressure logical model.
Guidance on how to interpret the contents of this table can be found here
0. BloodPressure | |
Definition | Blood Pressure |
Short | Blood Pressure LM |
Logical Model | Instances of this logical model are not marked to be the target of a Reference |
2. BloodPressure.systolicPressure | |
Definition | Peak systemic arterial blood pressure - measured in systolic or contraction phase of the heart cycle. |
Short | systolic blood pressure |
Control | 0..1 |
Type | BackboneElement |
4. BloodPressure.systolicPressure.code | |
Definition | code, in case of a precoordinated concept |
Short | code, in case of a precoordinated concept |
Control | 0..1 |
Binding | Unless not suitable, these codes SHALL be taken from Vital Signs Systolic Blood Pressure Codes (extensible to http://vitals.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code ) |
Type | CodeableConcept |
6. BloodPressure.systolicPressure.value | |
Definition | value |
Short | value |
Control | 1..1 |
Type | positiveInt |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Invariants | shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. ($this < 1000 ) |
8. BloodPressure.systolicPressure.unit | |
Definition | units |
Short | units |
Control | 1..1 |
Binding | The codes SHALL be taken from Blood Pressure Units (required to http://vitals.oemig.de/fhir/ValueSet/BPunits ) |
Type | CodeableConcept |
10. BloodPressure.systolicPressure.dataAbsentReason | |
Definition | Why the component result is missing |
Short | Why the component result is missing |
Control | 0..1 |
Binding | The codes SHALL be taken from DataAbsentReason (required to http://hl7.org/fhir/ValueSet/data-absent-reason ) |
Type | CodeableConcept |
12. BloodPressure.systolicPressure.interpretation | |
Definition | interpretation |
Short | interpretation |
Control | 0..1 |
Binding | The codes SHALL be taken from Interpretation (required to http://vitals.oemig.de/fhir/ValueSet/Interpretation ) |
Type | CodeableConcept |
14. BloodPressure.systolicPressure.range | |
Definition | reference range |
Short | reference range |
Control | 0..* |
Type | BackboneElement |
16. BloodPressure.systolicPressure.range.low | |
Definition | Low Range, if relevant |
Short | Low Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
18. BloodPressure.systolicPressure.range.high | |
Definition | High Range, if relevant |
Short | High Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
20. BloodPressure.systolicPressure.range.age | |
Definition | Applicable age range, if relevant |
Short | Applicable age range, if relevant |
Control | 0..1 |
Type | Range |
22. BloodPressure.systolicPressure.range.text | |
Definition | Text based reference range in an observation |
Short | Text based reference range in an observation |
Control | 0..1 |
Type | string |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
24. BloodPressure.diastolicPressure | |
Definition | Minimum systemic arterial blood pressure - measured in the diastolic or relaxation phase of the heart cycle. |
Short | diastolic blood pressure |
Control | 0..1 |
Type | BackboneElement |
26. BloodPressure.diastolicPressure.code | |
Definition | code, in case of a precoordinated concept |
Short | code, in case of a precoordinated concept |
Control | 0..1 |
Binding | Unless not suitable, these codes SHALL be taken from Vital Signs Diastolic Blood Pressure Codes (extensible to http://vitals.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code ) |
Type | CodeableConcept |
28. BloodPressure.diastolicPressure.value | |
Definition | value |
Short | value |
Control | 1..1 |
Type | positiveInt |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Invariants | shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. ($this < 1000 ) |
30. BloodPressure.diastolicPressure.unit | |
Definition | units |
Short | units |
Control | 1..1 |
Binding | The codes SHALL be taken from Blood Pressure Units (required to http://vitals.oemig.de/fhir/ValueSet/BPunits ) |
Type | CodeableConcept |
32. BloodPressure.diastolicPressure.dataAbsentReason | |
Definition | Why the component result is missing |
Short | Why the component result is missing |
Control | 0..1 |
Binding | The codes SHALL be taken from DataAbsentReason (required to http://hl7.org/fhir/ValueSet/data-absent-reason ) |
Type | CodeableConcept |
34. BloodPressure.diastolicPressure.interpretation | |
Definition | interpretation |
Short | interpretation |
Control | 0..1 |
Binding | The codes SHALL be taken from Interpretation (required to http://vitals.oemig.de/fhir/ValueSet/Interpretation ) |
Type | CodeableConcept |
36. BloodPressure.diastolicPressure.range | |
Definition | reference range |
Short | reference range |
Control | 0..* |
Type | BackboneElement |
38. BloodPressure.diastolicPressure.range.low | |
Definition | Low Range, if relevant |
Short | Low Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
40. BloodPressure.diastolicPressure.range.high | |
Definition | High Range, if relevant |
Short | High Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
42. BloodPressure.diastolicPressure.range.age | |
Definition | Applicable age range, if relevant |
Short | Applicable age range, if relevant |
Control | 0..1 |
Type | Range |
44. BloodPressure.diastolicPressure.range.text | |
Definition | Text based reference range in an observation |
Short | Text based reference range in an observation |
Control | 0..1 |
Type | string |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
46. BloodPressure.meanArterialPressure | |
Definition | The average arterial pressure that occurs over the entire course of the heart contraction and relaxation cycle. |
Short | mean arterial blood pressure |
Control | 0..1 |
Type | BackboneElement |
48. BloodPressure.meanArterialPressure.code | |
Definition | code, in case of a precoordinated concept |
Short | code, in case of a precoordinated concept |
Control | 0..1 |
Binding | Unless not suitable, these codes SHALL be taken from Vital Signs Mean Arterial Blood Pressure Codes (extensible to http://vitals.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code ) |
Type | CodeableConcept |
50. BloodPressure.meanArterialPressure.value | |
Definition | value |
Short | value |
Control | 1..1 |
Type | positiveInt |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Invariants | shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. ($this < 1000 ) |
52. BloodPressure.meanArterialPressure.unit | |
Definition | units |
Short | units |
Control | 1..1 |
Binding | The codes SHALL be taken from Blood Pressure Units (required to http://vitals.oemig.de/fhir/ValueSet/BPunits ) |
Type | CodeableConcept |
54. BloodPressure.meanArterialPressure.dataAbsentReason | |
Definition | Why the component result is missing |
Short | Why the component result is missing |
Control | 0..1 |
Binding | The codes SHALL be taken from DataAbsentReason (required to http://hl7.org/fhir/ValueSet/data-absent-reason ) |
Type | CodeableConcept |
56. BloodPressure.meanArterialPressure.interpretation | |
Definition | interpretation |
Short | interpretation |
Control | 0..1 |
Binding | The codes SHALL be taken from Interpretation (required to http://vitals.oemig.de/fhir/ValueSet/Interpretation ) |
Type | CodeableConcept |
58. BloodPressure.meanArterialPressure.range | |
Definition | reference range |
Short | reference range |
Control | 0..* |
Type | BackboneElement |
60. BloodPressure.meanArterialPressure.range.low | |
Definition | Low Range, if relevant |
Short | Low Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
62. BloodPressure.meanArterialPressure.range.high | |
Definition | High Range, if relevant |
Short | High Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
64. BloodPressure.meanArterialPressure.range.age | |
Definition | Applicable age range, if relevant |
Short | Applicable age range, if relevant |
Control | 0..1 |
Type | Range |
66. BloodPressure.meanArterialPressure.range.text | |
Definition | Text based reference range in an observation |
Short | Text based reference range in an observation |
Control | 0..1 |
Type | string |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
68. BloodPressure.pulsePressure | |
Definition | The difference between the systolic and diastolic pressure. |
Short | pulse blood pressure |
Control | 0..1 |
Type | BackboneElement |
70. BloodPressure.pulsePressure.code | |
Definition | code, in case of a precoordinated concept |
Short | code, in case of a precoordinated concept |
Control | 0..1 |
Binding | Unless not suitable, these codes SHALL be taken from Vital Signs Pulse Blood Pressure Codes (extensible to http://vitals.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code ) |
Type | CodeableConcept |
72. BloodPressure.pulsePressure.value | |
Definition | value |
Short | value |
Control | 1..1 |
Type | positiveInt |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Invariants | shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. ($this < 1000 ) |
74. BloodPressure.pulsePressure.unit | |
Definition | units |
Short | units |
Control | 1..1 |
Binding | The codes SHALL be taken from Blood Pressure Units (required to http://vitals.oemig.de/fhir/ValueSet/BPunits ) |
Type | CodeableConcept |
76. BloodPressure.pulsePressure.dataAbsentReason | |
Definition | Why the component result is missing |
Short | Why the component result is missing |
Control | 0..1 |
Binding | The codes SHALL be taken from DataAbsentReason (required to http://hl7.org/fhir/ValueSet/data-absent-reason ) |
Type | CodeableConcept |
78. BloodPressure.pulsePressure.interpretation | |
Definition | interpretation |
Short | interpretation |
Control | 0..1 |
Binding | The codes SHALL be taken from Interpretation (required to http://vitals.oemig.de/fhir/ValueSet/Interpretation ) |
Type | CodeableConcept |
80. BloodPressure.pulsePressure.range | |
Definition | reference range |
Short | reference range |
Control | 0..* |
Type | BackboneElement |
82. BloodPressure.pulsePressure.range.low | |
Definition | Low Range, if relevant |
Short | Low Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
84. BloodPressure.pulsePressure.range.high | |
Definition | High Range, if relevant |
Short | High Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
86. BloodPressure.pulsePressure.range.age | |
Definition | Applicable age range, if relevant |
Short | Applicable age range, if relevant |
Control | 0..1 |
Type | Range |
88. BloodPressure.pulsePressure.range.text | |
Definition | Text based reference range in an observation |
Short | Text based reference range in an observation |
Control | 0..1 |
Type | string |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
90. BloodPressure.interpretation | |
Definition | overall clinical meaning of the BP measurement |
Short | overall clinical meaning of the BP measurement |
Control | 0..1 |
Binding | The codes SHALL be taken from Interpretation (required to http://vitals.oemig.de/fhir/ValueSet/Interpretation ) |
Type | CodeableConcept |
92. BloodPressure.dataAbsentReason | |
Definition | Why the component result is missing |
Short | Why the component result is missing |
Control | 0..1 |
Binding | The codes SHALL be taken from DataAbsentReason (required to http://hl7.org/fhir/ValueSet/data-absent-reason ) |
Type | CodeableConcept |
94. BloodPressure.range | |
Definition | reference range |
Short | reference range |
Control | 0..* |
Type | BackboneElement |
96. BloodPressure.effective[x] | |
Definition | different representations |
Short | date of observation |
Control | 0..1 |
Type | Choice of: date, instant, Period |
[x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
98. BloodPressure.cuffType | |
Definition | type of cuff used (eg. rusable, disposable) |
Short | type of cuff used (eg. rusable, disposable) |
Control | 0..1 |
Binding | The codes SHALL be taken from Cuff Type (required to http://vitals.oemig.de/fhir/ValueSet/CuffType ) |
Type | CodeableConcept |
100. BloodPressure.cuffSize | |
Definition | size of cuff (eg. adult, child) |
Short | size of cuff (eg. adult, child) |
Control | 0..1 |
Binding | The codes SHALL be taken from Cuff Size (required to http://vitals.oemig.de/fhir/ValueSet/CuffSize ) |
Type | CodeableConcept |
102. BloodPressure.position | |
Definition | position for measurement |
Short | position for measurement |
Control | 0..1 |
Binding | The codes SHALL be taken from Position (required to http://vitals.oemig.de/fhir/ValueSet/Position ) |
Type | CodeableConcept |
104. BloodPressure.location | |
Definition | body location of measurement |
Short | body location of measurement |
Control | 0..1 |
Binding | The codes SHALL be taken from Location (required to http://vitals.oemig.de/fhir/ValueSet/Location ) |
Type | CodeableConcept |
106. BloodPressure.consciousness | |
Definition | Consciousness of the patient |
Short | Consciousness of the patient |
Control | 0..1 |
Binding | The codes SHALL be taken from Consciousness (required to http://vitals.oemig.de/fhir/ValueSet/Consciousness ) |
Type | CodeableConcept |
108. BloodPressure.exertion[x] | |
Definition | physical activity (measured in Watts or as coded information) |
Short | physical activity (measured in Watts or as coded information) |
Control | 0..1 |
Type | Choice of: integer, CodeableConcept |
[x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
110. BloodPressure.bodyWeight | |
Definition | body weight |
Short | body weight |
Control | 0..1 |
Type | http://vitals.oemig.de/fhir/StructureDefinition/BodyWeight |
112. BloodPressure.medication[x] | |
Definition | medication to be considered, minimum is the indication that there is some kind of medication |
Short | medication to be considered, minimum is the indication that there is some kind of medication |
Control | 0..1 |
Type | Choice of: boolean, Reference(MedicationStatement) |
[x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
114. BloodPressure.method | |
Definition | measurement method |
Short | measurement method |
Control | 0..1 |
Type | CodeableConcept |
116. BloodPressure.tilt | |
Definition | tilt (in degrees) |
Short | tilt (in degrees) |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
118. BloodPressure.comment | |
Definition | any comment |
Short | any comment |
Control | 0..1 |
Type | string |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
120. BloodPressure.subject | |
Definition | reference to the subject of the measurement |
Short | reference to the subject of the measurement |
Control | 0..1 |
Type | Reference(Patient) |
122. BloodPressure.author | |
Definition | reference to the author of the measurement |
Short | reference to the author of the measurement |
Control | 0..1 |
Type | Reference(Practitioner) |
124. BloodPressure.performer | |
Definition | reference to the performer of the measurement |
Short | reference to the performer of the measurement |
Control | 0..1 |
Type | Reference(Practitioner) |
Guidance on how to interpret the contents of this table can be found here
0. BloodPressure | |
Definition | Blood Pressure |
Short | Blood Pressure LM |
Control | 0..* |
Is Modifier | false |
Logical Model | Instances of this logical model are not marked to be the target of a Reference |
2. BloodPressure.systolicPressure | |
Definition | Peak systemic arterial blood pressure - measured in systolic or contraction phase of the heart cycle. |
Short | systolic blood pressure |
Control | 0..1 |
Type | BackboneElement |
Summary | true |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) |
4. BloodPressure.systolicPressure.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Short | Extensions that cannot be ignored even if unrecognized |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them |
Summary | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content, modifiers |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists()) |
6. BloodPressure.systolicPressure.code | |
Definition | code, in case of a precoordinated concept |
Short | code, in case of a precoordinated concept |
Control | 0..1 |
Binding | Unless not suitable, these codes SHALL be taken from Vital Signs Systolic Blood Pressure Codes (extensible to http://vitals.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code ) |
Type | CodeableConcept |
8. BloodPressure.systolicPressure.value | |
Definition | value |
Short | value |
Control | 1..1 |
Type | positiveInt |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Invariants | shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. ($this < 1000 ) |
10. BloodPressure.systolicPressure.unit | |
Definition | units |
Short | units |
Control | 1..1 |
Binding | The codes SHALL be taken from Blood Pressure Units (required to http://vitals.oemig.de/fhir/ValueSet/BPunits ) |
Type | CodeableConcept |
12. BloodPressure.systolicPressure.dataAbsentReason | |
Definition | Why the component result is missing |
Short | Why the component result is missing |
Control | 0..1 |
Binding | The codes SHALL be taken from DataAbsentReason (required to http://hl7.org/fhir/ValueSet/data-absent-reason ) |
Type | CodeableConcept |
14. BloodPressure.systolicPressure.interpretation | |
Definition | interpretation |
Short | interpretation |
Control | 0..1 |
Binding | The codes SHALL be taken from Interpretation (required to http://vitals.oemig.de/fhir/ValueSet/Interpretation ) |
Type | CodeableConcept |
16. BloodPressure.systolicPressure.range | |
Definition | reference range |
Short | reference range |
Control | 0..* |
Type | BackboneElement |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) |
18. BloodPressure.systolicPressure.range.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Short | Extensions that cannot be ignored even if unrecognized |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them |
Summary | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content, modifiers |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists()) |
20. BloodPressure.systolicPressure.range.low | |
Definition | Low Range, if relevant |
Short | Low Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
22. BloodPressure.systolicPressure.range.high | |
Definition | High Range, if relevant |
Short | High Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
24. BloodPressure.systolicPressure.range.age | |
Definition | Applicable age range, if relevant |
Short | Applicable age range, if relevant |
Control | 0..1 |
Type | Range |
26. BloodPressure.systolicPressure.range.text | |
Definition | Text based reference range in an observation |
Short | Text based reference range in an observation |
Control | 0..1 |
Type | string |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
28. BloodPressure.diastolicPressure | |
Definition | Minimum systemic arterial blood pressure - measured in the diastolic or relaxation phase of the heart cycle. |
Short | diastolic blood pressure |
Control | 0..1 |
Type | BackboneElement |
Summary | true |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) |
30. BloodPressure.diastolicPressure.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Short | Extensions that cannot be ignored even if unrecognized |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them |
Summary | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content, modifiers |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists()) |
32. BloodPressure.diastolicPressure.code | |
Definition | code, in case of a precoordinated concept |
Short | code, in case of a precoordinated concept |
Control | 0..1 |
Binding | Unless not suitable, these codes SHALL be taken from Vital Signs Diastolic Blood Pressure Codes (extensible to http://vitals.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code ) |
Type | CodeableConcept |
34. BloodPressure.diastolicPressure.value | |
Definition | value |
Short | value |
Control | 1..1 |
Type | positiveInt |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Invariants | shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. ($this < 1000 ) |
36. BloodPressure.diastolicPressure.unit | |
Definition | units |
Short | units |
Control | 1..1 |
Binding | The codes SHALL be taken from Blood Pressure Units (required to http://vitals.oemig.de/fhir/ValueSet/BPunits ) |
Type | CodeableConcept |
38. BloodPressure.diastolicPressure.dataAbsentReason | |
Definition | Why the component result is missing |
Short | Why the component result is missing |
Control | 0..1 |
Binding | The codes SHALL be taken from DataAbsentReason (required to http://hl7.org/fhir/ValueSet/data-absent-reason ) |
Type | CodeableConcept |
40. BloodPressure.diastolicPressure.interpretation | |
Definition | interpretation |
Short | interpretation |
Control | 0..1 |
Binding | The codes SHALL be taken from Interpretation (required to http://vitals.oemig.de/fhir/ValueSet/Interpretation ) |
Type | CodeableConcept |
42. BloodPressure.diastolicPressure.range | |
Definition | reference range |
Short | reference range |
Control | 0..* |
Type | BackboneElement |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) |
44. BloodPressure.diastolicPressure.range.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Short | Extensions that cannot be ignored even if unrecognized |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them |
Summary | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content, modifiers |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists()) |
46. BloodPressure.diastolicPressure.range.low | |
Definition | Low Range, if relevant |
Short | Low Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
48. BloodPressure.diastolicPressure.range.high | |
Definition | High Range, if relevant |
Short | High Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
50. BloodPressure.diastolicPressure.range.age | |
Definition | Applicable age range, if relevant |
Short | Applicable age range, if relevant |
Control | 0..1 |
Type | Range |
52. BloodPressure.diastolicPressure.range.text | |
Definition | Text based reference range in an observation |
Short | Text based reference range in an observation |
Control | 0..1 |
Type | string |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
54. BloodPressure.meanArterialPressure | |
Definition | The average arterial pressure that occurs over the entire course of the heart contraction and relaxation cycle. |
Short | mean arterial blood pressure |
Control | 0..1 |
Type | BackboneElement |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) |
56. BloodPressure.meanArterialPressure.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Short | Extensions that cannot be ignored even if unrecognized |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them |
Summary | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content, modifiers |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists()) |
58. BloodPressure.meanArterialPressure.code | |
Definition | code, in case of a precoordinated concept |
Short | code, in case of a precoordinated concept |
Control | 0..1 |
Binding | Unless not suitable, these codes SHALL be taken from Vital Signs Mean Arterial Blood Pressure Codes (extensible to http://vitals.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code ) |
Type | CodeableConcept |
60. BloodPressure.meanArterialPressure.value | |
Definition | value |
Short | value |
Control | 1..1 |
Type | positiveInt |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Invariants | shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. ($this < 1000 ) |
62. BloodPressure.meanArterialPressure.unit | |
Definition | units |
Short | units |
Control | 1..1 |
Binding | The codes SHALL be taken from Blood Pressure Units (required to http://vitals.oemig.de/fhir/ValueSet/BPunits ) |
Type | CodeableConcept |
64. BloodPressure.meanArterialPressure.dataAbsentReason | |
Definition | Why the component result is missing |
Short | Why the component result is missing |
Control | 0..1 |
Binding | The codes SHALL be taken from DataAbsentReason (required to http://hl7.org/fhir/ValueSet/data-absent-reason ) |
Type | CodeableConcept |
66. BloodPressure.meanArterialPressure.interpretation | |
Definition | interpretation |
Short | interpretation |
Control | 0..1 |
Binding | The codes SHALL be taken from Interpretation (required to http://vitals.oemig.de/fhir/ValueSet/Interpretation ) |
Type | CodeableConcept |
68. BloodPressure.meanArterialPressure.range | |
Definition | reference range |
Short | reference range |
Control | 0..* |
Type | BackboneElement |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) |
70. BloodPressure.meanArterialPressure.range.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Short | Extensions that cannot be ignored even if unrecognized |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them |
Summary | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content, modifiers |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists()) |
72. BloodPressure.meanArterialPressure.range.low | |
Definition | Low Range, if relevant |
Short | Low Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
74. BloodPressure.meanArterialPressure.range.high | |
Definition | High Range, if relevant |
Short | High Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
76. BloodPressure.meanArterialPressure.range.age | |
Definition | Applicable age range, if relevant |
Short | Applicable age range, if relevant |
Control | 0..1 |
Type | Range |
78. BloodPressure.meanArterialPressure.range.text | |
Definition | Text based reference range in an observation |
Short | Text based reference range in an observation |
Control | 0..1 |
Type | string |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
80. BloodPressure.pulsePressure | |
Definition | The difference between the systolic and diastolic pressure. |
Short | pulse blood pressure |
Control | 0..1 |
Type | BackboneElement |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) |
82. BloodPressure.pulsePressure.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Short | Extensions that cannot be ignored even if unrecognized |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them |
Summary | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content, modifiers |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists()) |
84. BloodPressure.pulsePressure.code | |
Definition | code, in case of a precoordinated concept |
Short | code, in case of a precoordinated concept |
Control | 0..1 |
Binding | Unless not suitable, these codes SHALL be taken from Vital Signs Pulse Blood Pressure Codes (extensible to http://vitals.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code ) |
Type | CodeableConcept |
86. BloodPressure.pulsePressure.value | |
Definition | value |
Short | value |
Control | 1..1 |
Type | positiveInt |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Invariants | shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. ($this < 1000 ) |
88. BloodPressure.pulsePressure.unit | |
Definition | units |
Short | units |
Control | 1..1 |
Binding | The codes SHALL be taken from Blood Pressure Units (required to http://vitals.oemig.de/fhir/ValueSet/BPunits ) |
Type | CodeableConcept |
90. BloodPressure.pulsePressure.dataAbsentReason | |
Definition | Why the component result is missing |
Short | Why the component result is missing |
Control | 0..1 |
Binding | The codes SHALL be taken from DataAbsentReason (required to http://hl7.org/fhir/ValueSet/data-absent-reason ) |
Type | CodeableConcept |
92. BloodPressure.pulsePressure.interpretation | |
Definition | interpretation |
Short | interpretation |
Control | 0..1 |
Binding | The codes SHALL be taken from Interpretation (required to http://vitals.oemig.de/fhir/ValueSet/Interpretation ) |
Type | CodeableConcept |
94. BloodPressure.pulsePressure.range | |
Definition | reference range |
Short | reference range |
Control | 0..* |
Type | BackboneElement |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) |
96. BloodPressure.pulsePressure.range.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Short | Extensions that cannot be ignored even if unrecognized |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them |
Summary | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content, modifiers |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists()) |
98. BloodPressure.pulsePressure.range.low | |
Definition | Low Range, if relevant |
Short | Low Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
100. BloodPressure.pulsePressure.range.high | |
Definition | High Range, if relevant |
Short | High Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
102. BloodPressure.pulsePressure.range.age | |
Definition | Applicable age range, if relevant |
Short | Applicable age range, if relevant |
Control | 0..1 |
Type | Range |
104. BloodPressure.pulsePressure.range.text | |
Definition | Text based reference range in an observation |
Short | Text based reference range in an observation |
Control | 0..1 |
Type | string |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
106. BloodPressure.interpretation | |
Definition | overall clinical meaning of the BP measurement |
Short | overall clinical meaning of the BP measurement |
Control | 0..1 |
Binding | The codes SHALL be taken from Interpretation (required to http://vitals.oemig.de/fhir/ValueSet/Interpretation ) |
Type | CodeableConcept |
Summary | true |
108. BloodPressure.dataAbsentReason | |
Definition | Why the component result is missing |
Short | Why the component result is missing |
Control | 0..1 |
Binding | The codes SHALL be taken from DataAbsentReason (required to http://hl7.org/fhir/ValueSet/data-absent-reason ) |
Type | CodeableConcept |
110. BloodPressure.range | |
Definition | reference range |
Short | reference range |
Control | 0..* |
Type | BackboneElement |
112. BloodPressure.effective[x] | |
Definition | different representations |
Short | date of observation |
Control | 0..1 |
Type | Choice of: date, instant, Period |
[x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Summary | true |
114. BloodPressure.cuffType | |
Definition | type of cuff used (eg. rusable, disposable) |
Short | type of cuff used (eg. rusable, disposable) |
Control | 0..1 |
Binding | The codes SHALL be taken from Cuff Type (required to http://vitals.oemig.de/fhir/ValueSet/CuffType ) |
Type | CodeableConcept |
116. BloodPressure.cuffSize | |
Definition | size of cuff (eg. adult, child) |
Short | size of cuff (eg. adult, child) |
Control | 0..1 |
Binding | The codes SHALL be taken from Cuff Size (required to http://vitals.oemig.de/fhir/ValueSet/CuffSize ) |
Type | CodeableConcept |
118. BloodPressure.position | |
Definition | position for measurement |
Short | position for measurement |
Control | 0..1 |
Binding | The codes SHALL be taken from Position (required to http://vitals.oemig.de/fhir/ValueSet/Position ) |
Type | CodeableConcept |
120. BloodPressure.location | |
Definition | body location of measurement |
Short | body location of measurement |
Control | 0..1 |
Binding | The codes SHALL be taken from Location (required to http://vitals.oemig.de/fhir/ValueSet/Location ) |
Type | CodeableConcept |
122. BloodPressure.consciousness | |
Definition | Consciousness of the patient |
Short | Consciousness of the patient |
Control | 0..1 |
Binding | The codes SHALL be taken from Consciousness (required to http://vitals.oemig.de/fhir/ValueSet/Consciousness ) |
Type | CodeableConcept |
124. BloodPressure.exertion[x] | |
Definition | physical activity (measured in Watts or as coded information) |
Short | physical activity (measured in Watts or as coded information) |
Control | 0..1 |
Type | Choice of: integer, CodeableConcept |
[x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
126. BloodPressure.bodyWeight | |
Definition | body weight |
Short | body weight |
Control | 0..1 |
Type | http://vitals.oemig.de/fhir/StructureDefinition/BodyWeight |
128. BloodPressure.medication[x] | |
Definition | medication to be considered, minimum is the indication that there is some kind of medication |
Short | medication to be considered, minimum is the indication that there is some kind of medication |
Control | 0..1 |
Type | Choice of: boolean, Reference(MedicationStatement) |
[x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
130. BloodPressure.method | |
Definition | measurement method |
Short | measurement method |
Control | 0..1 |
Type | CodeableConcept |
132. BloodPressure.tilt | |
Definition | tilt (in degrees) |
Short | tilt (in degrees) |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
134. BloodPressure.comment | |
Definition | any comment |
Short | any comment |
Control | 0..1 |
Type | string |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
136. BloodPressure.subject | |
Definition | reference to the subject of the measurement |
Short | reference to the subject of the measurement |
Control | 0..1 |
Type | Reference(Patient) |
138. BloodPressure.author | |
Definition | reference to the author of the measurement |
Short | reference to the author of the measurement |
Control | 0..1 |
Type | Reference(Practitioner) |
140. BloodPressure.performer | |
Definition | reference to the performer of the measurement |
Short | reference to the performer of the measurement |
Control | 0..1 |
Type | Reference(Practitioner) |
Guidance on how to interpret the contents of this table can be found here
0. BloodPressure | |
Definition | Blood Pressure |
Short | Blood Pressure LM |
Control | 0..* |
Is Modifier | false |
Logical Model | Instances of this logical model are not marked to be the target of a Reference |
2. BloodPressure.systolicPressure | |
Definition | Peak systemic arterial blood pressure - measured in systolic or contraction phase of the heart cycle. |
Short | systolic blood pressure |
Control | 0..1 |
Type | BackboneElement |
Summary | true |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) |
4. BloodPressure.systolicPressure.id | |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Short | Unique id for inter-element referencing |
Control | 0..1 |
Type | string |
Is Modifier | false |
XML Format | In the XML format, this property is represented as an attribute. |
Summary | false |
6. BloodPressure.systolicPressure.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Short | Additional content defined by implementations |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | false |
Summary | false |
Alternate Names | extensions, user content |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) |
Slicing | This element introduces a set of slices on BloodPressure.systolicPressure.extension . The slices areUnordered and Open, and can be differentiated using the following discriminators: |
8. BloodPressure.systolicPressure.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Short | Extensions that cannot be ignored even if unrecognized |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them |
Summary | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content, modifiers |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) |
10. BloodPressure.systolicPressure.code | |
Definition | code, in case of a precoordinated concept |
Short | code, in case of a precoordinated concept |
Control | 0..1 |
Binding | Unless not suitable, these codes SHALL be taken from Vital Signs Systolic Blood Pressure Codes (extensible to http://vitals.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code ) |
Type | CodeableConcept |
12. BloodPressure.systolicPressure.value | |
Definition | value |
Short | value |
Control | 1..1 |
Type | positiveInt |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Invariants | shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. ($this < 1000 ) |
14. BloodPressure.systolicPressure.unit | |
Definition | units |
Short | units |
Control | 1..1 |
Binding | The codes SHALL be taken from Blood Pressure Units (required to http://vitals.oemig.de/fhir/ValueSet/BPunits ) |
Type | CodeableConcept |
16. BloodPressure.systolicPressure.dataAbsentReason | |
Definition | Why the component result is missing |
Short | Why the component result is missing |
Control | 0..1 |
Binding | The codes SHALL be taken from DataAbsentReason (required to http://hl7.org/fhir/ValueSet/data-absent-reason ) |
Type | CodeableConcept |
18. BloodPressure.systolicPressure.interpretation | |
Definition | interpretation |
Short | interpretation |
Control | 0..1 |
Binding | The codes SHALL be taken from Interpretation (required to http://vitals.oemig.de/fhir/ValueSet/Interpretation ) |
Type | CodeableConcept |
20. BloodPressure.systolicPressure.range | |
Definition | reference range |
Short | reference range |
Control | 0..* |
Type | BackboneElement |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) |
22. BloodPressure.systolicPressure.range.id | |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Short | Unique id for inter-element referencing |
Control | 0..1 |
Type | string |
Is Modifier | false |
XML Format | In the XML format, this property is represented as an attribute. |
Summary | false |
24. BloodPressure.systolicPressure.range.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Short | Additional content defined by implementations |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | false |
Summary | false |
Alternate Names | extensions, user content |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) |
Slicing | This element introduces a set of slices on BloodPressure.systolicPressure.range.extension . The slices areUnordered and Open, and can be differentiated using the following discriminators: |
26. BloodPressure.systolicPressure.range.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Short | Extensions that cannot be ignored even if unrecognized |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them |
Summary | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content, modifiers |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) |
28. BloodPressure.systolicPressure.range.low | |
Definition | Low Range, if relevant |
Short | Low Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
30. BloodPressure.systolicPressure.range.high | |
Definition | High Range, if relevant |
Short | High Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
32. BloodPressure.systolicPressure.range.age | |
Definition | Applicable age range, if relevant |
Short | Applicable age range, if relevant |
Control | 0..1 |
Type | Range |
34. BloodPressure.systolicPressure.range.text | |
Definition | Text based reference range in an observation |
Short | Text based reference range in an observation |
Control | 0..1 |
Type | string |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
36. BloodPressure.diastolicPressure | |
Definition | Minimum systemic arterial blood pressure - measured in the diastolic or relaxation phase of the heart cycle. |
Short | diastolic blood pressure |
Control | 0..1 |
Type | BackboneElement |
Summary | true |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) |
38. BloodPressure.diastolicPressure.id | |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Short | Unique id for inter-element referencing |
Control | 0..1 |
Type | string |
Is Modifier | false |
XML Format | In the XML format, this property is represented as an attribute. |
Summary | false |
40. BloodPressure.diastolicPressure.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Short | Additional content defined by implementations |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | false |
Summary | false |
Alternate Names | extensions, user content |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) |
Slicing | This element introduces a set of slices on BloodPressure.diastolicPressure.extension . The slices areUnordered and Open, and can be differentiated using the following discriminators: |
42. BloodPressure.diastolicPressure.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Short | Extensions that cannot be ignored even if unrecognized |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them |
Summary | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content, modifiers |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) |
44. BloodPressure.diastolicPressure.code | |
Definition | code, in case of a precoordinated concept |
Short | code, in case of a precoordinated concept |
Control | 0..1 |
Binding | Unless not suitable, these codes SHALL be taken from Vital Signs Diastolic Blood Pressure Codes (extensible to http://vitals.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code ) |
Type | CodeableConcept |
46. BloodPressure.diastolicPressure.value | |
Definition | value |
Short | value |
Control | 1..1 |
Type | positiveInt |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Invariants | shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. ($this < 1000 ) |
48. BloodPressure.diastolicPressure.unit | |
Definition | units |
Short | units |
Control | 1..1 |
Binding | The codes SHALL be taken from Blood Pressure Units (required to http://vitals.oemig.de/fhir/ValueSet/BPunits ) |
Type | CodeableConcept |
50. BloodPressure.diastolicPressure.dataAbsentReason | |
Definition | Why the component result is missing |
Short | Why the component result is missing |
Control | 0..1 |
Binding | The codes SHALL be taken from DataAbsentReason (required to http://hl7.org/fhir/ValueSet/data-absent-reason ) |
Type | CodeableConcept |
52. BloodPressure.diastolicPressure.interpretation | |
Definition | interpretation |
Short | interpretation |
Control | 0..1 |
Binding | The codes SHALL be taken from Interpretation (required to http://vitals.oemig.de/fhir/ValueSet/Interpretation ) |
Type | CodeableConcept |
54. BloodPressure.diastolicPressure.range | |
Definition | reference range |
Short | reference range |
Control | 0..* |
Type | BackboneElement |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) |
56. BloodPressure.diastolicPressure.range.id | |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Short | Unique id for inter-element referencing |
Control | 0..1 |
Type | string |
Is Modifier | false |
XML Format | In the XML format, this property is represented as an attribute. |
Summary | false |
58. BloodPressure.diastolicPressure.range.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Short | Additional content defined by implementations |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | false |
Summary | false |
Alternate Names | extensions, user content |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) |
Slicing | This element introduces a set of slices on BloodPressure.diastolicPressure.range.extension . The slices areUnordered and Open, and can be differentiated using the following discriminators: |
60. BloodPressure.diastolicPressure.range.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Short | Extensions that cannot be ignored even if unrecognized |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them |
Summary | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content, modifiers |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) |
62. BloodPressure.diastolicPressure.range.low | |
Definition | Low Range, if relevant |
Short | Low Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
64. BloodPressure.diastolicPressure.range.high | |
Definition | High Range, if relevant |
Short | High Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
66. BloodPressure.diastolicPressure.range.age | |
Definition | Applicable age range, if relevant |
Short | Applicable age range, if relevant |
Control | 0..1 |
Type | Range |
68. BloodPressure.diastolicPressure.range.text | |
Definition | Text based reference range in an observation |
Short | Text based reference range in an observation |
Control | 0..1 |
Type | string |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
70. BloodPressure.meanArterialPressure | |
Definition | The average arterial pressure that occurs over the entire course of the heart contraction and relaxation cycle. |
Short | mean arterial blood pressure |
Control | 0..1 |
Type | BackboneElement |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) |
72. BloodPressure.meanArterialPressure.id | |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Short | Unique id for inter-element referencing |
Control | 0..1 |
Type | string |
Is Modifier | false |
XML Format | In the XML format, this property is represented as an attribute. |
Summary | false |
74. BloodPressure.meanArterialPressure.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Short | Additional content defined by implementations |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | false |
Summary | false |
Alternate Names | extensions, user content |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) |
Slicing | This element introduces a set of slices on BloodPressure.meanArterialPressure.extension . The slices areUnordered and Open, and can be differentiated using the following discriminators: |
76. BloodPressure.meanArterialPressure.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Short | Extensions that cannot be ignored even if unrecognized |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them |
Summary | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content, modifiers |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) |
78. BloodPressure.meanArterialPressure.code | |
Definition | code, in case of a precoordinated concept |
Short | code, in case of a precoordinated concept |
Control | 0..1 |
Binding | Unless not suitable, these codes SHALL be taken from Vital Signs Mean Arterial Blood Pressure Codes (extensible to http://vitals.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code ) |
Type | CodeableConcept |
80. BloodPressure.meanArterialPressure.value | |
Definition | value |
Short | value |
Control | 1..1 |
Type | positiveInt |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Invariants | shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. ($this < 1000 ) |
82. BloodPressure.meanArterialPressure.unit | |
Definition | units |
Short | units |
Control | 1..1 |
Binding | The codes SHALL be taken from Blood Pressure Units (required to http://vitals.oemig.de/fhir/ValueSet/BPunits ) |
Type | CodeableConcept |
84. BloodPressure.meanArterialPressure.dataAbsentReason | |
Definition | Why the component result is missing |
Short | Why the component result is missing |
Control | 0..1 |
Binding | The codes SHALL be taken from DataAbsentReason (required to http://hl7.org/fhir/ValueSet/data-absent-reason ) |
Type | CodeableConcept |
86. BloodPressure.meanArterialPressure.interpretation | |
Definition | interpretation |
Short | interpretation |
Control | 0..1 |
Binding | The codes SHALL be taken from Interpretation (required to http://vitals.oemig.de/fhir/ValueSet/Interpretation ) |
Type | CodeableConcept |
88. BloodPressure.meanArterialPressure.range | |
Definition | reference range |
Short | reference range |
Control | 0..* |
Type | BackboneElement |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) |
90. BloodPressure.meanArterialPressure.range.id | |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Short | Unique id for inter-element referencing |
Control | 0..1 |
Type | string |
Is Modifier | false |
XML Format | In the XML format, this property is represented as an attribute. |
Summary | false |
92. BloodPressure.meanArterialPressure.range.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Short | Additional content defined by implementations |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | false |
Summary | false |
Alternate Names | extensions, user content |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) |
Slicing | This element introduces a set of slices on BloodPressure.meanArterialPressure.range.extension . The slices areUnordered and Open, and can be differentiated using the following discriminators: |
94. BloodPressure.meanArterialPressure.range.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Short | Extensions that cannot be ignored even if unrecognized |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them |
Summary | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content, modifiers |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) |
96. BloodPressure.meanArterialPressure.range.low | |
Definition | Low Range, if relevant |
Short | Low Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
98. BloodPressure.meanArterialPressure.range.high | |
Definition | High Range, if relevant |
Short | High Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
100. BloodPressure.meanArterialPressure.range.age | |
Definition | Applicable age range, if relevant |
Short | Applicable age range, if relevant |
Control | 0..1 |
Type | Range |
102. BloodPressure.meanArterialPressure.range.text | |
Definition | Text based reference range in an observation |
Short | Text based reference range in an observation |
Control | 0..1 |
Type | string |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
104. BloodPressure.pulsePressure | |
Definition | The difference between the systolic and diastolic pressure. |
Short | pulse blood pressure |
Control | 0..1 |
Type | BackboneElement |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) |
106. BloodPressure.pulsePressure.id | |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Short | Unique id for inter-element referencing |
Control | 0..1 |
Type | string |
Is Modifier | false |
XML Format | In the XML format, this property is represented as an attribute. |
Summary | false |
108. BloodPressure.pulsePressure.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Short | Additional content defined by implementations |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | false |
Summary | false |
Alternate Names | extensions, user content |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) |
Slicing | This element introduces a set of slices on BloodPressure.pulsePressure.extension . The slices areUnordered and Open, and can be differentiated using the following discriminators: |
110. BloodPressure.pulsePressure.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Short | Extensions that cannot be ignored even if unrecognized |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them |
Summary | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content, modifiers |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) |
112. BloodPressure.pulsePressure.code | |
Definition | code, in case of a precoordinated concept |
Short | code, in case of a precoordinated concept |
Control | 0..1 |
Binding | Unless not suitable, these codes SHALL be taken from Vital Signs Pulse Blood Pressure Codes (extensible to http://vitals.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code ) |
Type | CodeableConcept |
114. BloodPressure.pulsePressure.value | |
Definition | value |
Short | value |
Control | 1..1 |
Type | positiveInt |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Invariants | shall-be-under-1000-mmHg: Value SHALL be <1000 mmHg for valid data. ($this < 1000 ) |
116. BloodPressure.pulsePressure.unit | |
Definition | units |
Short | units |
Control | 1..1 |
Binding | The codes SHALL be taken from Blood Pressure Units (required to http://vitals.oemig.de/fhir/ValueSet/BPunits ) |
Type | CodeableConcept |
118. BloodPressure.pulsePressure.dataAbsentReason | |
Definition | Why the component result is missing |
Short | Why the component result is missing |
Control | 0..1 |
Binding | The codes SHALL be taken from DataAbsentReason (required to http://hl7.org/fhir/ValueSet/data-absent-reason ) |
Type | CodeableConcept |
120. BloodPressure.pulsePressure.interpretation | |
Definition | interpretation |
Short | interpretation |
Control | 0..1 |
Binding | The codes SHALL be taken from Interpretation (required to http://vitals.oemig.de/fhir/ValueSet/Interpretation ) |
Type | CodeableConcept |
122. BloodPressure.pulsePressure.range | |
Definition | reference range |
Short | reference range |
Control | 0..* |
Type | BackboneElement |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) |
124. BloodPressure.pulsePressure.range.id | |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Short | Unique id for inter-element referencing |
Control | 0..1 |
Type | string |
Is Modifier | false |
XML Format | In the XML format, this property is represented as an attribute. |
Summary | false |
126. BloodPressure.pulsePressure.range.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Short | Additional content defined by implementations |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | false |
Summary | false |
Alternate Names | extensions, user content |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) |
Slicing | This element introduces a set of slices on BloodPressure.pulsePressure.range.extension . The slices areUnordered and Open, and can be differentiated using the following discriminators: |
128. BloodPressure.pulsePressure.range.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Short | Extensions that cannot be ignored even if unrecognized |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them |
Summary | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content, modifiers |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) |
130. BloodPressure.pulsePressure.range.low | |
Definition | Low Range, if relevant |
Short | Low Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
132. BloodPressure.pulsePressure.range.high | |
Definition | High Range, if relevant |
Short | High Range, if relevant |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
134. BloodPressure.pulsePressure.range.age | |
Definition | Applicable age range, if relevant |
Short | Applicable age range, if relevant |
Control | 0..1 |
Type | Range |
136. BloodPressure.pulsePressure.range.text | |
Definition | Text based reference range in an observation |
Short | Text based reference range in an observation |
Control | 0..1 |
Type | string |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
138. BloodPressure.interpretation | |
Definition | overall clinical meaning of the BP measurement |
Short | overall clinical meaning of the BP measurement |
Control | 0..1 |
Binding | The codes SHALL be taken from Interpretation (required to http://vitals.oemig.de/fhir/ValueSet/Interpretation ) |
Type | CodeableConcept |
Summary | true |
140. BloodPressure.dataAbsentReason | |
Definition | Why the component result is missing |
Short | Why the component result is missing |
Control | 0..1 |
Binding | The codes SHALL be taken from DataAbsentReason (required to http://hl7.org/fhir/ValueSet/data-absent-reason ) |
Type | CodeableConcept |
142. BloodPressure.range | |
Definition | reference range |
Short | reference range |
Control | 0..* |
Type | BackboneElement |
144. BloodPressure.effective[x] | |
Definition | different representations |
Short | date of observation |
Control | 0..1 |
Type | Choice of: date, instant, Period |
[x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Summary | true |
146. BloodPressure.cuffType | |
Definition | type of cuff used (eg. rusable, disposable) |
Short | type of cuff used (eg. rusable, disposable) |
Control | 0..1 |
Binding | The codes SHALL be taken from Cuff Type (required to http://vitals.oemig.de/fhir/ValueSet/CuffType ) |
Type | CodeableConcept |
148. BloodPressure.cuffSize | |
Definition | size of cuff (eg. adult, child) |
Short | size of cuff (eg. adult, child) |
Control | 0..1 |
Binding | The codes SHALL be taken from Cuff Size (required to http://vitals.oemig.de/fhir/ValueSet/CuffSize ) |
Type | CodeableConcept |
150. BloodPressure.position | |
Definition | position for measurement |
Short | position for measurement |
Control | 0..1 |
Binding | The codes SHALL be taken from Position (required to http://vitals.oemig.de/fhir/ValueSet/Position ) |
Type | CodeableConcept |
152. BloodPressure.location | |
Definition | body location of measurement |
Short | body location of measurement |
Control | 0..1 |
Binding | The codes SHALL be taken from Location (required to http://vitals.oemig.de/fhir/ValueSet/Location ) |
Type | CodeableConcept |
154. BloodPressure.consciousness | |
Definition | Consciousness of the patient |
Short | Consciousness of the patient |
Control | 0..1 |
Binding | The codes SHALL be taken from Consciousness (required to http://vitals.oemig.de/fhir/ValueSet/Consciousness ) |
Type | CodeableConcept |
156. BloodPressure.exertion[x] | |
Definition | physical activity (measured in Watts or as coded information) |
Short | physical activity (measured in Watts or as coded information) |
Control | 0..1 |
Type | Choice of: integer, CodeableConcept |
[x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
158. BloodPressure.bodyWeight | |
Definition | body weight |
Short | body weight |
Control | 0..1 |
Type | http://vitals.oemig.de/fhir/StructureDefinition/BodyWeight |
160. BloodPressure.medication[x] | |
Definition | medication to be considered, minimum is the indication that there is some kind of medication |
Short | medication to be considered, minimum is the indication that there is some kind of medication |
Control | 0..1 |
Type | Choice of: boolean, Reference(MedicationStatement) |
[x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
162. BloodPressure.method | |
Definition | measurement method |
Short | measurement method |
Control | 0..1 |
Type | CodeableConcept |
164. BloodPressure.tilt | |
Definition | tilt (in degrees) |
Short | tilt (in degrees) |
Control | 0..1 |
Type | integer |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
166. BloodPressure.comment | |
Definition | any comment |
Short | any comment |
Control | 0..1 |
Type | string |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
168. BloodPressure.subject | |
Definition | reference to the subject of the measurement |
Short | reference to the subject of the measurement |
Control | 0..1 |
Type | Reference(Patient) |
170. BloodPressure.author | |
Definition | reference to the author of the measurement |
Short | reference to the author of the measurement |
Control | 0..1 |
Type | Reference(Practitioner) |
172. BloodPressure.performer | |
Definition | reference to the performer of the measurement |
Short | reference to the performer of the measurement |
Control | 0..1 |
Type | Reference(Practitioner) |