Unable to compare with previous version: Unable to find version history at http://bloodpressure.oemig.de/fhir (Problem #1 with package-list.json at http://bloodpressure.oemig.de/fhir: bloodpressure.oemig.de)
IPA Comparison:
n/a
IPS Comparison:
n/a
Validation Flags:
On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings
The resource CodeSystem/Anaesthesia should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource CodeSystem/Consciousness should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource CodeSystem/CuffSize should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource CodeSystem/CuffType should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource CodeSystem/DeviceType should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource CodeSystem/Exertion should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource CodeSystem/Location should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource CodeSystem/ObservationCategory should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource CodeSystem/ObservationCodes should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource CodeSystem/Position should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource CodeSystem/v2DataTypes should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/bp|4.0.1 (this may not be a problem, but you should check that it's not intended to match a slice)Show Reasoning
This element does not match any known slice Defined in the profile http://hl7.org/fhir/StructureDefinition/bp|4.0.1 (this may not be a problem, but you should check that it's not intended to match a slice)
Observation.category[0]: discriminator = true and ('vital-signs' in coding.code) and ('http://terminology.hl7.org/CodeSystem/observation-category' in coding.system)
This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/bp|4.0.1 and slicing is CLOSED: Observation.value.ofType(Quantity): Does not match slice 'valueQuantity' (discriminator: $this.empty())Validation_VAL_Profile_NotSlice
Slice 'Observation.category:VSCat': a matching slice is required, but not found (from http://hl7.org/fhir/StructureDefinition/bp|4.0.1). Note that other slices are allowed in addition to this required sliceValidation_VAL_Profile_Minimum_SLICE
None of the codings provided are in the value set 'Observation Category Codes' (http://hl7.org/fhir/ValueSet/observation-category|4.0.1), and a coding is recommended to come from this value set (codes = http://bloodpressure.oemig.de/fhir/CodeSystem/ObservationCategory#vital-sign-bp)Terminology_TX_NoValid_3_CC
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier' to 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.3.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier' to 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.3.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
The definition for the element 'BloodPressure.systolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'BloodPressure.diastolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'BloodPressure.meanArterialPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'BloodPressure.pulsePressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
--
BloodPressure.device.serialNumber (l1/c273461)
information
The extension http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.3.0 is deprecated with the note: 'Use either ElementDefinition.code or ElementDefinition.mapping to provide the mapping instead'MSG_DEPENDS_ON_DEPRECATED_NOTE
The definition for the element 'BloodPressure.systolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'BloodPressure.diastolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'BloodPressure.meanArterialPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'BloodPressure.pulsePressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
--
Resource
information
The resource StructureDefinition/BloodPressure could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The definition for the element 'BloodPressureAverage.systolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'BloodPressureAverage.diastolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'BloodPressureAverage.systolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'BloodPressureAverage.diastolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
--
Resource
information
The resource StructureDefinition/BloodPressureLongTerm could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The markdown contains content that appears to be an embedded HTML tag starting at '<f'. This will (or SHOULD) be escaped by the presentation layer. The content should be checked to confirm that this is the desired behaviourTYPE_SPECIFIC_CHECKS_DT_MARKDOWN_HTML
The extension http://hl7.org/fhir/StructureDefinition/regex|5.3.0 is deprecated with the note: 'This was deprecated in favor of using a constraint on the element using FHIRPath, since constraints allow for the provision of a human readable message associated with the regex'MSG_DEPENDS_ON_DEPRECATED_NOTE
Constraint failed: eld-20: 'Element names should be simple alphanumerics with a max of 64 characters, or code generation tools may be broken (path.matches('[A-Za-z][A-Za-z0-9]*(\\.[a-z][A-Za-z0-9]*(\\[x])?)*'))'http://hl7.org/fhir/StructureDefinition/ElementDefinition#eld-20
Constraint failed: eld-20: 'Element names should be simple alphanumerics with a max of 64 characters, or code generation tools may be broken (path.matches('[A-Za-z][A-Za-z0-9]*(\\.[a-z][A-Za-z0-9]*(\\[x])?)*'))'http://hl7.org/fhir/StructureDefinition/ElementDefinition#eld-20
Constraint failed: eld-20: 'Element names should be simple alphanumerics with a max of 64 characters, or code generation tools may be broken (path.matches('[A-Za-z][A-Za-z0-9]*(\\.[a-z][A-Za-z0-9]*(\\[x])?)*'))'http://hl7.org/fhir/StructureDefinition/ElementDefinition#eld-20
Constraint failed: eld-20: 'Element names should be simple alphanumerics with a max of 64 characters, or code generation tools may be broken (path.matches('[A-Za-z][A-Za-z0-9]*(\\.[a-z][A-Za-z0-9]*(\\[x])?)*'))'http://hl7.org/fhir/StructureDefinition/ElementDefinition#eld-20
The resource StructureDefinition/BloodPressureMindMap could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource StructureDefinition/ConsciousnessExt could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.3.0 is deprecated with the note: 'Use additionalBinding extension or element instead'MSG_DEPENDS_ON_DEPRECATED_NOTE
The discriminator path 'system' does not appear to be valid for the element that is being sliced 'Observation.component'SD_PATH_NOT_VALID
--
StructureDefinition.snapshot (l1/c213145)
warning
The slice 'loinc' on path 'Observation.code.coding' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
--
StructureDefinition.snapshot (l1/c213145)
warning
The slice 'snomed' on path 'Observation.code.coding' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
--
StructureDefinition.snapshot (l1/c213145)
warning
The slice 'SystolicBP' on path 'Observation.component' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
--
StructureDefinition.snapshot (l1/c213145)
warning
The slice 'DiastolicBP' on path 'Observation.component' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
--
StructureDefinition.snapshot (l1/c213145)
warning
The slice 'meanBP' on path 'Observation.component' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
--
Resource
information
The resource StructureDefinition/IsikBloodPressure could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The discriminator path 'system' does not appear to be valid for the element that is being sliced 'SegmentGroup.segment'SD_PATH_NOT_VALID
--
Resource
information
The resource StructureDefinition/OBXbloodpressuresegmentgroup could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The definition for the element 'OBXsegment.observationCode' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'OBXsegment.observationCode' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
--
Resource
information
The resource StructureDefinition/OBXdiastolicBP could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
A definition for CodeSystem 'http://bloodpressure.oemig.de/fhir/CodeSystem/v2DataType' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4) UNKNOWN_CODESYSTEM
A definition for CodeSystem 'http://bloodpressure.oemig.de/fhir/CodeSystem/v2DataType' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4) UNKNOWN_CODESYSTEM
The resource StructureDefinition/OBXmainBP could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
A definition for CodeSystem 'http://bloodpressure.oemig.de/fhir/CodeSystem/v2DataType' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4) UNKNOWN_CODESYSTEM
A definition for CodeSystem 'http://bloodpressure.oemig.de/fhir/CodeSystem/v2DataType' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4) UNKNOWN_CODESYSTEM
The definition for the element 'OBXsegment.observationCode' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'OBXsegment.observationCode' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
--
Resource
information
The resource StructureDefinition/OBXsystolicBP could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier' to 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.3.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier' to 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.3.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
The resource StructureDefinition/PIDsegment could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier' to 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.3.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier' to 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.3.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
The resource StructureDefinition/RELsegment could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource StructureDefinition/bodweightExt could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource StructureDefinition/diastolicExt could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource StructureDefinition/exertionExt could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource StructureDefinition/medicationExt could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource StructureDefinition/systolicExt could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
--
Resource
error
The OID '2.16.840.1.113883.4.642.40.42.6' is also used by us-core-modified-blood-pressure-2 in /scratch/repo/fsh-generated/resources/StructureDefinition-us-core-modified-blood-pressure-2
--
Resource
error
The OID '2.16.840.1.113883.4.642.40.42.6' is also used by us-core-modified-blood-pressure in /scratch/repo/fsh-generated/resources/StructureDefinition-us-core-modified-blood-pressure
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition' to 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition|5.3.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition' to 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition|5.3.0'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
--
Resource
error
The OID '2.16.840.1.113883.4.642.40.42.6' has already been used by us-core-blood-pressure in /scratch/repo/fsh-generated/resources/StructureDefinition-us-core-blood-pressure
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
--
Resource
error
The OID '2.16.840.1.113883.4.642.40.42.6' has already been used by us-core-blood-pressure in /scratch/repo/fsh-generated/resources/StructureDefinition-us-core-blood-pressure
The resource StructureDefinition/us-core-modified-vital-signs could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/Anaesthesia should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/BPunits should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/BodyPosition should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/Consciousness should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/CuffSize should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/CuffType should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/DeviceType should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/Exertion should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/Interpretation should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/Location should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/MeasurementSetting should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/ObservationCategory should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/ObservationCodes should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/ObservationVitalSignsBPCategory should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/ObservationVitalSignsCategory should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/Position should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-body-position.json - the canonical URL (http://bloodpressure.oemig.de/fhir/ValueSet/body-position) does not match the URL (http://bloodpressure.oemig.de/fhir/ValueSet/body_position). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
The resource ValueSet/body-position should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
--
ValueSet.where(id = 'body-position')
warning
Error from https://tx.fhir.org/r4: Error: A definition for CodeSystem 'http://bloodpressure.oemig.de/fhir/ValueSet/body_position_core' could not be found, so the value set cannot be expanded (from server, see log)
--
fsh-generated/resources/ValueSet-body-position
error
URL Mismatch http://bloodpressure.oemig.de/fhir/ValueSet/body-position vs http://bloodpressure.oemig.de/fhir/ValueSet/body_position
The concepts in the value set include have not been validated because the code system 'http://snomed.sct' is not known, and no terminology service supports itVALUESET_INC_CS_NO_SUPPORT
--
Resource
warning
The resource ValueSet/body-position-core should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
--
ValueSet.where(id = 'body-position-core')
warning
Error from https://tx.fhir.org/r4: Error: A definition for CodeSystem 'http://snomed.sct' could not be found, so the value set cannot be expanded (from server, see log)
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-body-position-xtended.json - the canonical URL (http://bloodpressure.oemig.de/fhir/ValueSet/body-position-xtended) does not match the URL (http://bloodpressure.oemig.de/fhir/ValueSet/body-position-extended). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
The concepts in the value set include have not been validated because the code system 'http://snomed.sct' is not known, and no terminology service supports itVALUESET_INC_CS_NO_SUPPORT
--
Resource
warning
The resource ValueSet/body-position-xtended should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
--
ValueSet.where(id = 'body-position-xtended')
warning
Error from https://tx.fhir.org/r4: Error: A definition for CodeSystem 'http://snomed.sct' could not be found, so the value set cannot be expanded (from server, see log)
The code 'moreDiastolicCodesToAdd' is not valid in the system http://loinc.org (Unknown code 'moreDiastolicCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.82')VALUESET_INCLUDE_INVALID_CONCEPT_CODE
--
Resource
warning
The resource ValueSet/us-core-diastolic-blood-pressure-code should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The code 'moreMeanArterialCodesToAdd' is not valid in the system http://loinc.org (Unknown code 'moreMeanArterialCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.82')VALUESET_INCLUDE_INVALID_CONCEPT_CODE
--
Resource
warning
The resource ValueSet/us-core-mean-arterial-blood-pressure-code should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/us-core-modified-blood-pressure-category should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The code 'moreCodesToAdd' is not valid in the system http://loinc.org (Unknown code 'moreCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.82')VALUESET_INCLUDE_INVALID_CONCEPT_CODE
--
Resource
warning
The resource ValueSet/us-core-modified-blood-pressure-code should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The code 'morePulseCodesToAdd' is not valid in the system http://loinc.org (Unknown code 'morePulseCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.82')VALUESET_INCLUDE_INVALID_CONCEPT_CODE
--
Resource
warning
The resource ValueSet/us-core-pulse-blood-pressure-code should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The code 'moreSystolicCodesToAdd' is not valid in the system http://loinc.org (Unknown code 'moreSystolicCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.82')VALUESET_INCLUDE_INVALID_CONCEPT_CODE
--
Resource
warning
The resource ValueSet/us-core-systolic-blood-pressure-code should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/v2DataTypes should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/bp|4.0.1 (this may not be a problem, but you should check that it's not intended to match a slice)
The extension http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.3.0 is deprecated with the note: 'Use either ElementDefinition.code or ElementDefinition.mapping to provide the mapping instead'
The extension http://hl7.org/fhir/StructureDefinition/regex|5.3.0 is deprecated with the note: 'This was deprecated in favor of using a constraint on the element using FHIRPath, since constraints allow for the provision of a human readable message associated with the regex'
The extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.3.0 is deprecated with the note: 'Use additionalBinding extension or element instead'
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-body-position.json - the canonical URL (http://bloodpressure.oemig.de/fhir/ValueSet/body-position) does not match the URL (http://bloodpressure.oemig.de/fhir/ValueSet/body_position). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-body-position-xtended.json - the canonical URL (http://bloodpressure.oemig.de/fhir/ValueSet/body-position-xtended) does not match the URL (http://bloodpressure.oemig.de/fhir/ValueSet/body-position-extended). Use the special-url parameter if you really mean for it not to match
The definition for the element 'BloodPressure.systolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressure.diastolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressure.meanArterialPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressure.pulsePressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressure.systolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressure.diastolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressure.meanArterialPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressure.pulsePressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressureAverage.systolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressureAverage.diastolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressureAverage.systolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'BloodPressureAverage.diastolicPressure.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'OBXsegment.observationCode' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'OBXsegment.observationCode' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'OBXsegment.observationCode' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'OBXsegment.observationCode' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-systolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-diastolic-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-mean-arterial-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.component.code' binds to the value set 'http://bloodpressure.oemig.de/fhir/ValueSet/us-core-pulse-blood-pressure-code' which is experimental, but this structure is not labeled as experimental
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The string value contains text that looks like embedded HTML tags. If this content is rendered to HTML without appropriate post-processing, it may be a security risk
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier' to 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.3.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier' to 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.3.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier' to 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.3.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier' to 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.3.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier' to 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.3.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier' to 'http://hl7.org/fhir/StructureDefinition/elementdefinition-identifier|5.3.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition' to 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition|5.3.0'
There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition' to 'http://hl7.org/fhir/StructureDefinition/observation-bodyPosition|5.3.0'
The markdown contains content that appears to be an embedded HTML tag starting at '<f'. This will (or SHOULD) be escaped by the presentation layer. The content should be checked to confirm that this is the desired behaviour
None of the codings provided are in the value set 'Observation Category Codes' (http://hl7.org/fhir/ValueSet/observation-category|4.0.1), and a coding is recommended to come from this value set (codes = http://bloodpressure.oemig.de/fhir/CodeSystem/ObservationCategory#vital-sign-bp)
The code 'moreDiastolicCodesToAdd' is not valid in the system http://loinc.org (Unknown code 'moreDiastolicCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.82')
The code 'moreMeanArterialCodesToAdd' is not valid in the system http://loinc.org (Unknown code 'moreMeanArterialCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.82')
The code 'moreCodesToAdd' is not valid in the system http://loinc.org (Unknown code 'moreCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.82')
The code 'morePulseCodesToAdd' is not valid in the system http://loinc.org (Unknown code 'morePulseCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.82')
The code 'moreSystolicCodesToAdd' is not valid in the system http://loinc.org (Unknown code 'moreSystolicCodesToAdd' in the CodeSystem 'http://loinc.org' version '2.82')
The concepts in the value set include have not been validated because the code system 'http://snomed.sct' is not known, and no terminology service supports it
The concepts in the value set include have not been validated because the code system 'http://snomed.sct' is not known, and no terminology service supports it
Slice 'Observation.category:VSCat': a matching slice is required, but not found (from http://hl7.org/fhir/StructureDefinition/bp|4.0.1). Note that other slices are allowed in addition to this required slice
This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/bp|4.0.1 and slicing is CLOSED: Observation.value.ofType(Quantity): Does not match slice 'valueQuantity' (discriminator: $this.empty())