Lithuanian Vital Signs Implementation Guide
0.0.1 - ci-build Lithuania vėliava

Lithuanian Vital Signs Implementation Guide, published by Lithuanian Medical Library. This guide is not an authorized publication; it is the continuous build for version 0.0.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7LT/ig-lt-vitalsigns/ and changes regularly. See the Directory of published versions

: BP Systolic observation codes

Active nuo 2026-04-10

Neapdorotas xml | Atsisiųsti


<ValueSet xmlns="http://hl7.org/fhir">
  <id value="bp-systolic-observation"/>
  <meta>
    <lastUpdated value="2025-10-26T17:42:56.640+00:00"/>
    <profile
             value="http://hl7.org/fhir/StructureDefinition/shareablevalueset|5.0.0"/>
  </meta>
  <language value="lt"/>
  <text>
    <status value="generated"/>
    <div xml:lang="lt" lang="lt"><hr/><p><b>Lithuanian</b></p><hr/><p class="res-header-id"><b>Generated Narrative: ValueSet bp-systolic-observation</b></p><a name="lt-bp-systolic-observation"> </a><a name="lt-hcbp-systolic-observation"> </a><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Last updated: 2025-10-26 17:42:56+0000; Language: en</p><p style="margin-bottom: 0px">Profile: <a href="http://hl7.org/fhir/R5/shareablevalueset.html">Shareable ValueSet</a> version: 5.0.0</p></div><ul><li>Include codes from<a href="http://loinc.org"><code>http://loinc.org</code></a><span title="Version is not explicitly stated. No matching Code System found"> version Not Stated (use latest from terminology server)</span> where COMPONENT  in LP72836-7,LP304522-8,LP304524-4,LP304523-6,LP304513-7, PROPERTY  = LP6847-0 (Pres), TIME_ASPCT  = LP6960-1 (Pt), SYSTEM  = LP7034-4 (Arterial system) and SCALE_TYP  = LP7753-9 (Qn)</li></ul></div>
  </text>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
    <valueCode value="oo"/>
  </extension>
  <url value="https://tx.hl7.lt/fhir/ValueSet/bp-systolic-observation"/>
  <version value="6.0.0"/>
  <name value="BloodPressureSystolicObservation"/>
  <title value="BP Systolic observation codes"/>
  <status value="active"/>
  <experimental value="false"/>
  <date value="2026-04-10T05:24:00+00:00"/>
  <publisher value="Lietuvos medicinos biblioteka"/>
  <contact>
    <name value="Lithuanian Medical Library"/>
    <telecom>
      <system value="url"/>
      <value value="https://medicinosnk.lt"/>
    </telecom>
    <telecom>
      <system value="email"/>
      <value value="info@medicinosnk.lt"/>
    </telecom>
  </contact>
  <description
               value="This value set defines the set of LOINC codes considered to be appropriate for representing an arterial systolic BP vital sign measurement in Observation.component.code."/>
  <jurisdiction>
    <coding>
      <system value="urn:iso:std:iso:3166"/>
      <code value="LT"/>
    </coding>
  </jurisdiction>
  <copyright
             value="This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use"/>
  <compose>
    <include>
      <system value="http://loinc.org"/>
      <filter>
        <property value="COMPONENT"/>
        <op value="in"/>
        <value value="LP72836-7,LP304522-8,LP304524-4,LP304523-6,LP304513-7"/>
      </filter>
      <filter>
        <property value="PROPERTY"/>
        <op value="="/>
        <value value="LP6847-0"/>
      </filter>
      <filter>
        <property value="TIME_ASPCT"/>
        <op value="="/>
        <value value="LP6960-1"/>
      </filter>
      <filter>
        <property value="SYSTEM"/>
        <op value="="/>
        <value value="LP7034-4"/>
      </filter>
      <filter>
        <property value="SCALE_TYP"/>
        <op value="="/>
        <value value="LP7753-9"/>
      </filter>
    </include>
  </compose>
</ValueSet>