Lithuanian Prostate Diagnostics Implementation Guide
0.0.1 - ci-build
Lithuanian Prostate Diagnostics Implementation Guide, published by Lithuanian Medical Library. This guide is not an authorized publication; it is the continuous build for version 0.0.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7LT/ig-lt-prostate/ and changes regularly. See the Directory of published versions
Lithuanian
Language: en
status: Final
code: PRECISE longitudinal assessment
effective: 2026-03-15 10:30:00+0000
value: PRECISE 4 - Likely progression
note:
Follow-up MRI shows likely progression compared to prior study; progression driven by lesion growth and increased DWI restriction.
component
code: New lesion indicator
value: false
component
code: Change pattern
value: Local change
component
code: Best MRI sequence for change assessment
value: Diffusion weighted
component
code: Best MRI sequence for change assessment
value: Apparent Diffusion Coefficient
component
code: Size change in millimeters
value: 3 mm (Details: UCUM codemm = 'mm')
component
code: PSAD dimension 1 (mm, axial)
value: 12 mm (Details: UCUM codemm = 'mm')
component
code: PSAD dimension 2 (mm, axial)
value: 9 mm (Details: UCUM codemm = 'mm')
component
code: PSAD dimension 3 (mm, coronal/sagittal)
value: 11 mm (Details: UCUM codemm = 'mm')
component
code: Change volume (cm³)
value: 0.6 cm3 (Details: UCUM codecm3 = 'cm3')
component
code: Likert scale (assessment scale)
value: 4
component
code: Prostate Imaging-Reporting and Data System score
value: 3
component
code: Prior TNM stage
value: cT2 N0 M0
component
code: Structure of capsule of prostate (body structure)
value: Absent (qualifier value)
component
code: Seminal vesicle structure (body structure)
value: Absent (qualifier value)