Point-of-Care Device Implementation Guide, published by HL7 International / Devices. This guide is not an authorized publication; it is the continuous build for version 1.0.0-ballot3 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/uv-pocd/ and changes regularly. See the Directory of published versions
| Official URL: http://hl7.org/fhir/StructureDefinition/measurement-resolution | Version: 1.0.0-ballot3 | ||||
| Standards status: Trial-use | Maturity Level: 2 | Computable Name: Resolution | |||
| Other Identifiers: OID:2.16.840.1.113883.4.642.40.72.42.23 | |||||
StructureDefinition that adds resolution to a DeviceMetric. Note: Resolution differs from accuracy — resolution describes the finest distinction a device can display, whereas accuracy describes how close a measured value is to the true value.
Context of Use
This extension may be used on the following element(s)
DeviceMetric
This extension is intended to move to the FHIR Core Extensions Pack after the ballot.
Usage info
Usages:
You can also check for usages in the FHIR IG Statistics
Description Differentials, Snapshots, and other representations.
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | Extension | Minimum determinable difference | |
![]() ![]() |
0..0 | Extension | ||
![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/StructureDefinition/measurement-resolution" | |
![]() ![]() |
1..1 | decimal | Value of extension | |
Documentation for this format | ||||
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | Extension | Minimum determinable difference | |
![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||
![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/StructureDefinition/measurement-resolution" | |
![]() ![]() |
1..1 | decimal | Value of extension Slice: Unordered, Closed by type:$this | |
![]() ![]() ![]() |
1..1 | decimal | Value of extension | |
Documentation for this format | ||||
| Id | Grade | Path(s) | Description | Expression |
Summary
Simple Extension with the type decimal: StructureDefinition that adds resolution to a DeviceMetric. Note: Resolution differs from accuracy — resolution describes the finest distinction a device can display, whereas accuracy describes how close a measured value is to the true value.
Maturity: 2
Differential ViewDifferential View
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | Extension | Minimum determinable difference | |
![]() ![]() |
0..0 | Extension | ||
![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/StructureDefinition/measurement-resolution" | |
![]() ![]() |
1..1 | decimal | Value of extension | |
Documentation for this format | ||||
Snapshot View
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | Extension | Minimum determinable difference | |
![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||
![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/StructureDefinition/measurement-resolution" | |
![]() ![]() |
1..1 | decimal | Value of extension Slice: Unordered, Closed by type:$this | |
![]() ![]() ![]() |
1..1 | decimal | Value of extension | |
Documentation for this format | ||||
| Id | Grade | Path(s) | Description | Expression |
Summary
Simple Extension with the type decimal: StructureDefinition that adds resolution to a DeviceMetric. Note: Resolution differs from accuracy — resolution describes the finest distinction a device can display, whereas accuracy describes how close a measured value is to the true value.
Maturity: 2
Other representations of profile: CSV, Excel, Schematron