Most of the information on the CDC and ATSDR websites is not subject to copyright, is in the public domain, and may be freely used or reproduced without obtaining copyright permission. For information and exceptions regarding use of CDC material please see https://www.cdc.gov/other/agencymaterials.html
The UCUM codes, UCUM table (regardless of format), and UCUM Specification are copyright 1999-2009, Regenstrief Institute, Inc. and the Unified Codes for Units of Measures (UCUM) Organization. All rights reserved. https://ucum.org/trac/wiki/TermsOfUse
This material contains content that is copyright of SNOMED International. Implementers of these specifications must have the appropriate SNOMED CT Affiliate license - for more information contact https://www.snomed.org/get-snomed
or info@snomed.org
.
Using RxNorm codes of type SAB=RXNORM as this specification describes does not require a UMLS license. Access to the full set of RxNorm definitions, and/or additional use of other RxNorm structures and information requires a UMLS license. The use of RxNorm in this specification is pursuant to HL7's status as a licensee of the NLM UMLS. HL7's license does not convey the right to use RxNorm to any users of this specification; implementers must acquire a license to use RxNorm in their own right.
Further guidance on using Value Set Authority Center (VSAC) Resources with FHIR® Terminology Service
can be found here. ( src
)
QI-Core Implementation Guide, published by HL7 International / Clinical Quality Information. This guide is not an authorized publication; it is the continuous build for version 7.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/fhir-qi-core/ and changes regularly. See the Directory of published versions ( src
)
There are examples where a medication request may include the option of an oral dose or an Intravenous or Intramuscular dose. For example, "Ondansetron 8mg orally or IV twice a day as needed for nausea" or "Compazine® (prochlorperazine) 5-10mg PO or 25mg PR bid prn nausea or vomiting". In these cases, two medication requests would be created that could be grouped together. The decision on which dose and route of administration to use is based on the patient's condition at the time the dose is needed. ( src
)
QI-Core Implementation Guide, published by HL7 International / Clinical Quality Information. This guide is not an authorized publication; it is the continuous build for version 7.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/fhir-qi-core/
and changes regularly. See the Directory of published versions
Unless not suitable, these codes SHALL be taken from AcquisitionModality
( extensible
to http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_29.html
)
The clinical test or procedure result value. If a numeric value, valueQuantity.code SHALL
be selected from UCUM
. A FHIR UCUM Codes value set
that defines all UCUM codes is in the FHIR specification.
The Laboratory result value. If a coded value, the valueCodeableConcept.code SHOULD
be selected from SNOMED CT
if the concept exists. If a numeric value, valueQuantity.code SHALL
be selected from UCUM
. A FHIR UCUM Codes value set
that defines all UCUM codes is in the FHIR specification.
The UCUM codes, UCUM table (regardless of format), and UCUM Specification are copyright 1999-2009, Regenstrief Institute, Inc. and the Unified Codes for Units of Measures (UCUM) Organization. All rights reserved. https://ucum.org/trac/wiki/TermsOfUse
This IG contains only one QI-Core-specific extension "QI-Core Key Element Extension" to enable entry of (QI) references to specific profile elements. Otherwise, this IG uses only FHIR or US Core extensions. Other initiatives that the QI-Core effort is aligning with include the
Clinical Information Modeling Initiative (CIMI)
and Graphite Health
.
The patterns described here have been developed through usage of QI-Core profiles in the development of
CQL-based quality measures and decision support. CMS program measures can be accessed at HealthIT.gov
. Multiple repositories of draft FHIR-based measures have been developed and are indexed in the eCQM Content Index
repository.
NOTE: The examples in this section follow recommended best-practices as of the time of publication. However, these practices are constantly being revised based on implementer and community feedback. For a complete discussion of authoring patterns, see the Authoring Patterns
topic in the CQL Formatting and Usage Wiki.
•ValueQuantity.system - Fixed Value:http://unitsofmeasure.org
•ValueQuantity.code - Coded responses from the common UCUM units for vital signs value set - Fixed Value:
kg/m2
•Body Height – Fixed Value:
8302-2
•ValueQuantity.system - Fixed Value:http://unitsofmeasure.org
•ValueQuantity.code - - Coded responses from the common UCUM units for vital signs value set - Binding:BodyLengthUnits
( required
)
•Body Temperature – Fixed Value:
8310-5
•ValueQuantity.system - Fixed Value:http://unitsofmeasure.org
•ValueQuantity.code - - Coded responses from the common UCUM units for vital signs value set – Binding:BodyTemperatureUnits
( required
)
•Body Weight – Fixed Value:
29463-7
•ValueQuantity.system - Fixed Value:http://unitsofmeasure.org
•ValueQuantity.code – Coded responses from the common UCUM units for vital signs value set – Binding:BodyWeightUnits
( required
)
•Head Circumference – Fixed Value:
9843-4
•ValueQuantity.system - Fixed Value:http://unitsofmeasure.org
•ValueQuantity.code - Coded responses from the common UCUM units for vital signs value set - Binding:BodyLengthUnits
( required
)
•Pediatric Weight for Height – Fixed Value:
77606-2
•ValueQuantity.system - Fixed Value:http://unitsofmeasure.org
•ValueQuantity.code - Coded responses from the common UCUM units for vital signs value set. Fixed Value:
%
•Vital Signs – Respiratory Rate – Fixed Value:
9279-1
•ValueQuantity.system - Fixed Value:http://unitsofmeasure.org
•ValueQuantity.code - Coded responses from the common UCUM units for vital signs value set - Fixed Value:
/min