QI-Core Implementation Guide, published by HL7 International / Clinical Quality Information. This guide is not an authorized publication; it is the continuous build for version 7.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/fhir-qi-core/ and changes regularly. See the Directory of published versions
Official URL: http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-deviceusestatement | Version: 7.0.0 | |||
Active as of 2018-08-22 | Computable Name: QICoreDeviceUseStatement |
Profile of DeviceUseStatement for decision support/quality metrics. Defines the core set of elements and extensions for quality rule and measure authors.
The provision of a wheelchair to a patient example |
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from DeviceUseStatement
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
DeviceUseStatement | 0..* | DeviceUseStatement | Record of use of a device | |
status | 1..1 | code | (QI) active | completed | entered-in-error + | |
subject | 1..1 | Reference(QICore Patient) | (QI) Patient using device | |
timing[x] | 0..1 | Timing, Period, dateTime | (QI) How often the device was used | |
recordedOn | 0..1 | dateTime | (QI) When statement was recorded | |
device | 1..1 | Reference(QICore Device | US Core Implantable Device Profile) | (QI) Reference to device used | |
bodySite | 0..1 | CodeableConcept | (QI) Target body site Binding: SNOMEDCTBodyStructures (preferred): Codes describing anatomical locations. May include laterality. | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
DeviceUseStatement.bodySite | preferred | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-site from the FHIR Standard |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
DeviceUseStatement | 0..* | DeviceUseStatement | Record of use of a device | |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
status | ?!Σ | 1..1 | code | (QI) active | completed | entered-in-error + Binding: DeviceUseStatementStatus (required): A coded concept indicating the current status of the Device Usage. |
subject | Σ | 1..1 | Reference(QICore Patient) | (QI) Patient using device |
timing[x] | Σ | 0..1 | (QI) How often the device was used | |
timingTiming | Timing | |||
timingPeriod | Period | |||
timingDateTime | dateTime | |||
recordedOn | Σ | 0..1 | dateTime | (QI) When statement was recorded |
device | Σ | 1..1 | Reference(QICore Device | US Core Implantable Device Profile) | (QI) Reference to device used |
bodySite | Σ | 0..1 | CodeableConcept | (QI) Target body site Binding: SNOMEDCTBodyStructures (preferred): Codes describing anatomical locations. May include laterality. |
Documentation for this format |
Path | Conformance | ValueSet | URI |
DeviceUseStatement.status | required | DeviceUseStatementStatushttp://hl7.org/fhir/ValueSet/device-statement-status|4.0.1 from the FHIR Standard | |
DeviceUseStatement.bodySite | preferred | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-site from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | DeviceUseStatement | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | DeviceUseStatement | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | DeviceUseStatement | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | DeviceUseStatement | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | DeviceUseStatement | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
DeviceUseStatement | 0..* | DeviceUseStatement | Record of use of a device | |||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | External identifier for this record | ||||
basedOn | Σ | 0..* | Reference(ServiceRequest) | Fulfills plan, proposal or order | ||||
status | ?!Σ | 1..1 | code | (QI) active | completed | entered-in-error + Binding: DeviceUseStatementStatus (required): A coded concept indicating the current status of the Device Usage. | ||||
subject | Σ | 1..1 | Reference(QICore Patient) | (QI) Patient using device | ||||
derivedFrom | Σ | 0..* | Reference(ServiceRequest | Procedure | Claim | Observation | QuestionnaireResponse | DocumentReference) | Supporting information | ||||
timing[x] | Σ | 0..1 | (QI) How often the device was used | |||||
timingTiming | Timing | |||||||
timingPeriod | Period | |||||||
timingDateTime | dateTime | |||||||
recordedOn | Σ | 0..1 | dateTime | (QI) When statement was recorded | ||||
source | Σ | 0..1 | Reference(Patient | Practitioner | PractitionerRole | RelatedPerson) | Who made the statement | ||||
device | Σ | 1..1 | Reference(QICore Device | US Core Implantable Device Profile) | (QI) Reference to device used | ||||
reasonCode | Σ | 0..* | CodeableConcept | Why device was used | ||||
reasonReference | Σ | 0..* | Reference(Condition | Observation | DiagnosticReport | DocumentReference | Media) | Why was DeviceUseStatement performed? | ||||
bodySite | Σ | 0..1 | CodeableConcept | (QI) Target body site Binding: SNOMEDCTBodyStructures (preferred): Codes describing anatomical locations. May include laterality. | ||||
note | 0..* | Annotation | Addition details (comments, instructions) | |||||
Documentation for this format |
Path | Conformance | ValueSet | URI | |||
DeviceUseStatement.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
DeviceUseStatement.status | required | DeviceUseStatementStatushttp://hl7.org/fhir/ValueSet/device-statement-status|4.0.1 from the FHIR Standard | ||||
DeviceUseStatement.bodySite | preferred | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-site from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | DeviceUseStatement | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | DeviceUseStatement | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | DeviceUseStatement | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | DeviceUseStatement | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | DeviceUseStatement | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
This structure is derived from DeviceUseStatement
Differential View
This structure is derived from DeviceUseStatement
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
DeviceUseStatement | 0..* | DeviceUseStatement | Record of use of a device | |
status | 1..1 | code | (QI) active | completed | entered-in-error + | |
subject | 1..1 | Reference(QICore Patient) | (QI) Patient using device | |
timing[x] | 0..1 | Timing, Period, dateTime | (QI) How often the device was used | |
recordedOn | 0..1 | dateTime | (QI) When statement was recorded | |
device | 1..1 | Reference(QICore Device | US Core Implantable Device Profile) | (QI) Reference to device used | |
bodySite | 0..1 | CodeableConcept | (QI) Target body site Binding: SNOMEDCTBodyStructures (preferred): Codes describing anatomical locations. May include laterality. | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
DeviceUseStatement.bodySite | preferred | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-site from the FHIR Standard |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
DeviceUseStatement | 0..* | DeviceUseStatement | Record of use of a device | |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
status | ?!Σ | 1..1 | code | (QI) active | completed | entered-in-error + Binding: DeviceUseStatementStatus (required): A coded concept indicating the current status of the Device Usage. |
subject | Σ | 1..1 | Reference(QICore Patient) | (QI) Patient using device |
timing[x] | Σ | 0..1 | (QI) How often the device was used | |
timingTiming | Timing | |||
timingPeriod | Period | |||
timingDateTime | dateTime | |||
recordedOn | Σ | 0..1 | dateTime | (QI) When statement was recorded |
device | Σ | 1..1 | Reference(QICore Device | US Core Implantable Device Profile) | (QI) Reference to device used |
bodySite | Σ | 0..1 | CodeableConcept | (QI) Target body site Binding: SNOMEDCTBodyStructures (preferred): Codes describing anatomical locations. May include laterality. |
Documentation for this format |
Path | Conformance | ValueSet | URI |
DeviceUseStatement.status | required | DeviceUseStatementStatushttp://hl7.org/fhir/ValueSet/device-statement-status|4.0.1 from the FHIR Standard | |
DeviceUseStatement.bodySite | preferred | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-site from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | DeviceUseStatement | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | DeviceUseStatement | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | DeviceUseStatement | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | DeviceUseStatement | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | DeviceUseStatement | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
DeviceUseStatement | 0..* | DeviceUseStatement | Record of use of a device | |||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | External identifier for this record | ||||
basedOn | Σ | 0..* | Reference(ServiceRequest) | Fulfills plan, proposal or order | ||||
status | ?!Σ | 1..1 | code | (QI) active | completed | entered-in-error + Binding: DeviceUseStatementStatus (required): A coded concept indicating the current status of the Device Usage. | ||||
subject | Σ | 1..1 | Reference(QICore Patient) | (QI) Patient using device | ||||
derivedFrom | Σ | 0..* | Reference(ServiceRequest | Procedure | Claim | Observation | QuestionnaireResponse | DocumentReference) | Supporting information | ||||
timing[x] | Σ | 0..1 | (QI) How often the device was used | |||||
timingTiming | Timing | |||||||
timingPeriod | Period | |||||||
timingDateTime | dateTime | |||||||
recordedOn | Σ | 0..1 | dateTime | (QI) When statement was recorded | ||||
source | Σ | 0..1 | Reference(Patient | Practitioner | PractitionerRole | RelatedPerson) | Who made the statement | ||||
device | Σ | 1..1 | Reference(QICore Device | US Core Implantable Device Profile) | (QI) Reference to device used | ||||
reasonCode | Σ | 0..* | CodeableConcept | Why device was used | ||||
reasonReference | Σ | 0..* | Reference(Condition | Observation | DiagnosticReport | DocumentReference | Media) | Why was DeviceUseStatement performed? | ||||
bodySite | Σ | 0..1 | CodeableConcept | (QI) Target body site Binding: SNOMEDCTBodyStructures (preferred): Codes describing anatomical locations. May include laterality. | ||||
note | 0..* | Annotation | Addition details (comments, instructions) | |||||
Documentation for this format |
Path | Conformance | ValueSet | URI | |||
DeviceUseStatement.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
DeviceUseStatement.status | required | DeviceUseStatementStatushttp://hl7.org/fhir/ValueSet/device-statement-status|4.0.1 from the FHIR Standard | ||||
DeviceUseStatement.bodySite | preferred | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-site from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | DeviceUseStatement | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | DeviceUseStatement | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | DeviceUseStatement | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | DeviceUseStatement | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | DeviceUseStatement | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
This structure is derived from DeviceUseStatement
Other representations of profile: CSV, Excel, Schematron