Order Catalog Implementation Guide
current - CI Build International flag

Order Catalog Implementation Guide, published by HL7 International - Orders and Observations Work Group. This is not an authorized publication; it is the continuous build for version current). This version is based on the current content of https://github.com/HL7/fhir-order-catalog/ and changes regularly. See the Directory of published versions

: Lab specimen capillary serum - XML Representation

Raw xml | Download



<SpecimenDefinition xmlns="http://hl7.org/fhir">
  <id value="example-specimen-capillary-serum-single-test"/>
  <meta>
    <profile
             value="http://hl7.org/fhir/uv/order-catalog/StructureDefinition/LabSpecimenDefinition"/>
  </meta>
  <language value="en-US"/>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml" xml:lang="en-US" lang="en-US"><p><b>Generated Narrative: SpecimenDefinition</b><a name="example-specimen-capillary-serum-single-test"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource SpecimenDefinition &quot;example-specimen-capillary-serum-single-test&quot;  (Language &quot;en-US&quot;) </p><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-LabSpecimenDefinition.html">Laboratory IVD Specimen Definition</a></p></div><p><b>url</b>: <code>http://hl7.org/fhir/uv/order-catalog/SpecimenDefinition/example-specimen-capillary-serum-single-test</code></p><p><b>status</b>: active</p><p><b>typeCollected</b>: Capillary blood specimen (specimen) <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#122554006)</span></p><p><b>collection</b>: Capillary specimen collection (procedure) <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#1048003)</span></p><blockquote><p><b>typeTested</b></p><p><b>type</b>: Serum <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.0.0/CodeSystem-v2-0487.html">specimenType</a>#SER)</span></p><p><b>preference</b>: preferred</p><h3>Containers</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Material</b></td><td><b>Type</b></td><td><b>Cap</b></td><td><b>Description</b></td><td><b>Capacity</b></td><td><b>MinimumVolume[x]</b></td></tr><tr><td style="display: none">*</td><td>plastic <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#61088005 &quot;Plastic&quot;)</span></td><td>Evacuated blood collection tube with clot activator <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#767384004)</span></td><td>red cap <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.0.0/CodeSystem-container-cap.html">ContainerCap</a>#red)</span></td><td>red cap plastic tube 2 mL</td><td>2 milliliter<span style="background: LightGoldenRodYellow"> (Details: UCUM code mL = 'mL')</span></td><td>0.5 milliliter<span style="background: LightGoldenRodYellow"> (Details: UCUM code mL = 'mL')</span></td></tr></table><h3>RetentionTimes</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td style="display: none">*</td><td>24</td><td>hour</td><td><a href="http://terminology.hl7.org/5.0.0/CodeSystem-v3-ucum.html">Unified Code for Units of Measure (UCUM)</a></td><td>h</td></tr></table><p><b>rejectionCriterion</b>: blood specimen hemolized <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.0.0/CodeSystem-rejection-criteria.html">RejectionCriterion</a>#hemolized)</span>, insufficient quantity of specimen <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.0.0/CodeSystem-rejection-criteria.html">RejectionCriterion</a>#insufficient)</span></p><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: room temperature or refrigerated <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> ()</span></p><h3>MaxDurations</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td style="display: none">*</td><td>7</td><td>day</td><td><a href="http://terminology.hl7.org/5.0.0/CodeSystem-v3-ucum.html">Unified Code for Units of Measure (UCUM)</a></td><td>d</td></tr></table></blockquote><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: frozen <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> ()</span></p><h3>MaxDurations</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td style="display: none">*</td><td>28</td><td>day</td><td><a href="http://terminology.hl7.org/5.0.0/CodeSystem-v3-ucum.html">Unified Code for Units of Measure (UCUM)</a></td><td>d</td></tr></table></blockquote></blockquote><blockquote><p><b>typeTested</b></p><p><b>type</b>: Plasma <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.0.0/CodeSystem-v2-0487.html">specimenType</a>#PLAS)</span></p><p><b>preference</b>: alternate</p><h3>Containers</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Type</b></td><td><b>Cap</b></td><td><b>Description</b></td><td><b>Capacity</b></td><td><b>MinimumVolume[x]</b></td></tr><tr><td style="display: none">*</td><td>Evacuated blood collection tube with heparin lithium and gel separator <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#767390000)</span></td><td>green cap <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.0.0/CodeSystem-container-cap.html">ContainerCap</a>#green)</span></td><td>green cap plastic tube 2 mL</td><td>2 milliliter<span style="background: LightGoldenRodYellow"> (Details: UCUM code mL = 'mL')</span></td><td>0.5 milliliter<span style="background: LightGoldenRodYellow"> (Details: UCUM code mL = 'mL')</span></td></tr></table><h3>RetentionTimes</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td style="display: none">*</td><td>24</td><td>hour</td><td><a href="http://terminology.hl7.org/5.0.0/CodeSystem-v3-ucum.html">Unified Code for Units of Measure (UCUM)</a></td><td>h</td></tr></table><p><b>rejectionCriterion</b>: blood specimen hemolized <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.0.0/CodeSystem-rejection-criteria.html">RejectionCriterion</a>#hemolized)</span>, insufficient quantity of specimen <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.0.0/CodeSystem-rejection-criteria.html">RejectionCriterion</a>#insufficient)</span></p><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: room temperature or refrigerated <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> ()</span></p><h3>MaxDurations</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td style="display: none">*</td><td>7</td><td>day</td><td><a href="http://terminology.hl7.org/5.0.0/CodeSystem-v3-ucum.html">Unified Code for Units of Measure (UCUM)</a></td><td>d</td></tr></table></blockquote><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: frozen <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> ()</span></p><h3>MaxDurations</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td style="display: none">*</td><td>28</td><td>day</td><td><a href="http://terminology.hl7.org/5.0.0/CodeSystem-v3-ucum.html">Unified Code for Units of Measure (UCUM)</a></td><td>d</td></tr></table></blockquote></blockquote></div>
  </text>
  <url
       value="http://hl7.org/fhir/uv/order-catalog/SpecimenDefinition/example-specimen-capillary-serum-single-test"/>
  <status value="active"/>
  <typeCollected>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="122554006"/>
      <display value="Capillary blood specimen (specimen)"/>
    </coding>
  </typeCollected>
  <collection>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="1048003"/>
      <display value="Capillary specimen collection (procedure)"/>
    </coding>
  </collection>
  <typeTested>
    <type>
      <coding>
        <system value="http://terminology.hl7.org/CodeSystem/v2-0487"/>
        <code value="SER"/>
        <display value="Serum"/>
      </coding>
    </type>
    <preference value="preferred"/>
    <container>
      <material>
        <coding>
          <system value="http://snomed.info/sct"/>
          <code value="61088005"/>
          <display value="Plastic"/>
        </coding>
        <text value="plastic"/>
      </material>
      <type>
        <coding>
          <system value="http://snomed.info/sct"/>
          <code value="767384004"/>
          <display
                   value="Evacuated blood collection tube with clot activator"/>
        </coding>
      </type>
      <cap>
        <coding>
          <system
                  value="http://terminology.hl7.org/CodeSystem/container-cap"/>
          <code value="red"/>
        </coding>
        <text value="red cap"/>
      </cap>
      <description value="red cap plastic tube 2 mL"/>
      <capacity>
        <value value="2"/>
        <unit value="milliliter"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="mL"/>
      </capacity>
      <minimumVolumeQuantity>
        <value value="0.5"/>
        <unit value="milliliter"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="mL"/>
      </minimumVolumeQuantity>
    </container>
    <retentionTime>
      <value value="24"/>
      <unit value="hour"/>
      <system value="http://unitsofmeasure.org"/>
      <code value="h"/>
    </retentionTime>
    <rejectionCriterion>
      <coding>
        <system
                value="http://terminology.hl7.org/CodeSystem/rejection-criteria"/>
        <code value="hemolized"/>
      </coding>
      <text value="blood specimen hemolized"/>
    </rejectionCriterion>
    <rejectionCriterion>
      <coding>
        <system
                value="http://terminology.hl7.org/CodeSystem/rejection-criteria"/>
        <code value="insufficient"/>
      </coding>
      <text value="insufficient quantity of specimen"/>
    </rejectionCriterion>
    <handling>
      <temperatureQualifier>
        <text value="room temperature or refrigerated"/>
      </temperatureQualifier>
      <maxDuration>
        <value value="7"/>
        <unit value="day"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="d"/>
      </maxDuration>
    </handling>
    <handling>
      <temperatureQualifier>
        <text value="frozen"/>
      </temperatureQualifier>
      <maxDuration>
        <value value="28"/>
        <unit value="day"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="d"/>
      </maxDuration>
    </handling>
  </typeTested>
  <typeTested>
    <type>
      <coding>
        <system value="http://terminology.hl7.org/CodeSystem/v2-0487"/>
        <code value="PLAS"/>
        <display value="Plasma"/>
      </coding>
    </type>
    <preference value="alternate"/>
    <container>
      <type>
        <coding>
          <system value="http://snomed.info/sct"/>
          <code value="767390000"/>
          <display
                   value="Evacuated blood collection tube with heparin lithium and gel separator"/>
        </coding>
      </type>
      <cap>
        <coding>
          <system
                  value="http://terminology.hl7.org/CodeSystem/container-cap"/>
          <code value="green"/>
        </coding>
        <text value="green cap"/>
      </cap>
      <description value="green cap plastic tube 2 mL"/>
      <capacity>
        <value value="2"/>
        <unit value="milliliter"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="mL"/>
      </capacity>
      <minimumVolumeQuantity>
        <value value="0.5"/>
        <unit value="milliliter"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="mL"/>
      </minimumVolumeQuantity>
    </container>
    <retentionTime>
      <value value="24"/>
      <unit value="hour"/>
      <system value="http://unitsofmeasure.org"/>
      <code value="h"/>
    </retentionTime>
    <rejectionCriterion>
      <coding>
        <system
                value="http://terminology.hl7.org/CodeSystem/rejection-criteria"/>
        <code value="hemolized"/>
      </coding>
      <text value="blood specimen hemolized"/>
    </rejectionCriterion>
    <rejectionCriterion>
      <coding>
        <system
                value="http://terminology.hl7.org/CodeSystem/rejection-criteria"/>
        <code value="insufficient"/>
      </coding>
      <text value="insufficient quantity of specimen"/>
    </rejectionCriterion>
    <handling>
      <temperatureQualifier>
        <text value="room temperature or refrigerated"/>
      </temperatureQualifier>
      <maxDuration>
        <value value="7"/>
        <unit value="day"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="d"/>
      </maxDuration>
    </handling>
    <handling>
      <temperatureQualifier>
        <text value="frozen"/>
      </temperatureQualifier>
      <maxDuration>
        <value value="28"/>
        <unit value="day"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="d"/>
      </maxDuration>
    </handling>
  </typeTested>
</SpecimenDefinition>