International Patient Summary Implementation Guide, published by HL7 International / Patient Care. This guide is not an authorized publication; it is the continuous build for version 2.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/fhir-ips/ and changes regularly. See the Directory of published versions
| Official URL: http://hl7.org/fhir/uv/ips/StructureDefinition/Device-uv-ips | Version: 2.0.0 | |||
| Standards status: Trial-use Active as of 2024-06-19 | Maturity Level: 3 | Computable Name: DeviceUvIps | ||
This profile represents the constraints applied to the Device resource by the International Patient Summary (IPS) FHIR Implementation Guide, based on FHIR R4. A device used by or implanted on the patient is described in the patient summary as an instance of a Device resource constrained by this profile.
This profile follows the HL7 Cross Paradigm Implementation Guide: UDI Pattern guidelines for exchanging information about the use and implantation of medical devices in patients. While a unique device identifier (UDI) is not required in this profile, it consists of a unique numeric or alphanumeric code, which may be machine-readable. The UDI generally consists of a mandatory Device Identifier (DI) and a conditional Production identifier (PI) that identifies one or more of the five UDI-PI elements. The UDI and its components may be mapped using the guidance in FHIR UDI Mapping
Usages:
You can also check for usages in the FHIR IG Statistics
Description Differentials, Snapshots, and other representations.
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
0..* | Device | Item used in healthcare | |||||||||
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||||||
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||||||
![]() ![]() |
Σ | 0..* | BackboneElement | Unique Device Identifier (UDI) carrier. See IPS Device profile description for more detail and mapping link. | ||||||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||
![]() ![]() |
?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||||||
![]() ![]() |
SO | 0..1 | CodeableConceptIPS | Type of device. Binding: Medical Devices - IPS (preferred): The type of device or a code for absent/unknown device
| ||||||||
Documentation for this format | ||||||||||||
| Name | Creator (IPS) | Consumer (IPS)![]() |
|---|---|---|
![]() |
||
![]() ![]() |
|
|
Documentation for this format | ||
| Path | Status | Usage | ValueSet | Version | Source |
| Device.status | Base | required | FHIRDeviceStatus | 📍4.0.1 | FHIR Std. |
| Device.type | Base | preferred | Medical Devices - IPS | 📦2.0.0 | This IG |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Device | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
0..* | Device | Item used in healthcare | |||||||||
![]() ![]() |
0..* | BackboneElement | Unique Device Identifier (UDI) carrier. See IPS Device profile description for more detail and mapping link. | |||||||||
![]() ![]() |
SO | 0..1 | CodeableConceptIPS | Type of device. Binding: Medical Devices - IPS (preferred): The type of device or a code for absent/unknown device
| ||||||||
Documentation for this format | ||||||||||||
| Name | Creator (IPS) | Consumer (IPS)![]() |
|---|---|---|
![]() |
||
![]() ![]() |
|
|
Documentation for this format | ||
| Path | Status | Usage | ValueSet | Version | Source |
| Device.type | Base | preferred | Medical Devices - IPS | 📦2.0.0 | This IG |
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
0..* | Device | Item used in healthcare | |||||||||
![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||||||
![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||||||
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||||||
![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||||||
![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation This profile does not constrain the narrative in regard to content, language, or traceability to data elements | |||||||||
![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||||||
![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||||||
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||||||
![]() ![]() |
0..* | Identifier | Instance identifier | |||||||||
![]() ![]() |
0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | |||||||||
![]() ![]() |
Σ | 0..* | BackboneElement | Unique Device Identifier (UDI) carrier. See IPS Device profile description for more detail and mapping link. | ||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||
![]() ![]() ![]() |
Σ | 0..1 | string | Mandatory fixed portion of UDI | ||||||||
![]() ![]() ![]() |
0..1 | uri | UDI Issuing Organization | |||||||||
![]() ![]() ![]() |
0..1 | uri | Regional UDI authority | |||||||||
![]() ![]() ![]() |
Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||||||
![]() ![]() ![]() |
Σ | 0..1 | string | UDI Human Readable Barcode String | ||||||||
![]() ![]() ![]() |
0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||||||
![]() ![]() |
?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||||||
![]() ![]() |
0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||||||
![]() ![]() |
0..1 | string | The distinct identification string | |||||||||
![]() ![]() |
0..1 | string | Name of device manufacturer | |||||||||
![]() ![]() |
0..1 | dateTime | Date when the device was made | |||||||||
![]() ![]() |
0..1 | dateTime | Date and time of expiry of this device (if applicable) | |||||||||
![]() ![]() |
0..1 | string | Lot number of manufacture | |||||||||
![]() ![]() |
0..1 | string | Serial number assigned by the manufacturer | |||||||||
![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer | |||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||
![]() ![]() ![]() |
1..1 | string | The name of the device | |||||||||
![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||||||
![]() ![]() |
0..1 | string | The model number for the device | |||||||||
![]() ![]() |
0..1 | string | The part number of the device | |||||||||
![]() ![]() |
SO | 0..1 | CodeableConceptIPS | Type of device. Binding: Medical Devices - IPS (preferred): The type of device or a code for absent/unknown device
| ||||||||
![]() ![]() |
0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||
![]() ![]() ![]() |
1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||||||
![]() ![]() ![]() |
0..1 | string | The version of the standard that is used to operate and communicate | |||||||||
![]() ![]() |
0..* | BackboneElement | The actual design of the device or software version running on the device | |||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||
![]() ![]() ![]() |
0..1 | CodeableConcept | The type of the device version | |||||||||
![]() ![]() ![]() |
0..1 | Identifier | A single component of the device version | |||||||||
![]() ![]() ![]() |
1..1 | string | The version text | |||||||||
![]() ![]() |
0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | |||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||
![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||||||
![]() ![]() ![]() |
0..* | Quantity | Property value as a quantity | |||||||||
![]() ![]() ![]() |
0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||||||
![]() ![]() |
0..1 | Reference(Patient) | Patient to whom Device is affixed | |||||||||
![]() ![]() |
0..1 | Reference(Organization) | Organization responsible for device | |||||||||
![]() ![]() |
0..* | ContactPoint | Details for human/organization for support | |||||||||
![]() ![]() |
0..1 | Reference(Location) | Where the device is found | |||||||||
![]() ![]() |
0..1 | uri | Network address to contact device | |||||||||
![]() ![]() |
0..* | Annotation | Device notes and comments | |||||||||
![]() ![]() |
Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||||||
![]() ![]() |
0..1 | Reference(Device) | The parent device | |||||||||
Documentation for this format | ||||||||||||
| Name | Creator (IPS) | Consumer (IPS)![]() |
|---|---|---|
![]() |
||
![]() ![]() |
|
|
Documentation for this format | ||
| Path | Status | Usage | ValueSet | Version | Source |
| Device.language | Base | preferred | Common Languages | 📍4.0.1 | FHIR Std. |
| Device.udiCarrier.entryType | Base | required | UDIEntryType | 📍4.0.1 | FHIR Std. |
| Device.status | Base | required | FHIRDeviceStatus | 📍4.0.1 | FHIR Std. |
| Device.statusReason | Base | extensible | FHIRDeviceStatusReason | 📍4.0.1 | FHIR Std. |
| Device.deviceName.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| Device.type | Base | preferred | Medical Devices - IPS | 📦2.0.0 | This IG |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Device | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
Summary
Must-Support: 1 element
Structures
This structure refers to these other structures:
Maturity: 3
Key Elements View
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
0..* | Device | Item used in healthcare | |||||||||
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||||||
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||||||
![]() ![]() |
Σ | 0..* | BackboneElement | Unique Device Identifier (UDI) carrier. See IPS Device profile description for more detail and mapping link. | ||||||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||
![]() ![]() |
?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||||||
![]() ![]() |
SO | 0..1 | CodeableConceptIPS | Type of device. Binding: Medical Devices - IPS (preferred): The type of device or a code for absent/unknown device
| ||||||||
Documentation for this format | ||||||||||||
| Name | Creator (IPS) | Consumer (IPS)![]() |
|---|---|---|
![]() |
||
![]() ![]() |
|
|
Documentation for this format | ||
| Path | Status | Usage | ValueSet | Version | Source |
| Device.status | Base | required | FHIRDeviceStatus | 📍4.0.1 | FHIR Std. |
| Device.type | Base | preferred | Medical Devices - IPS | 📦2.0.0 | This IG |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Device | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
Differential View
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
0..* | Device | Item used in healthcare | |||||||||
![]() ![]() |
0..* | BackboneElement | Unique Device Identifier (UDI) carrier. See IPS Device profile description for more detail and mapping link. | |||||||||
![]() ![]() |
SO | 0..1 | CodeableConceptIPS | Type of device. Binding: Medical Devices - IPS (preferred): The type of device or a code for absent/unknown device
| ||||||||
Documentation for this format | ||||||||||||
| Name | Creator (IPS) | Consumer (IPS)![]() |
|---|---|---|
![]() |
||
![]() ![]() |
|
|
Documentation for this format | ||
| Path | Status | Usage | ValueSet | Version | Source |
| Device.type | Base | preferred | Medical Devices - IPS | 📦2.0.0 | This IG |
Snapshot ViewView
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
0..* | Device | Item used in healthcare | |||||||||
![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||||||
![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||||||
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||||||
![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||||||
![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation This profile does not constrain the narrative in regard to content, language, or traceability to data elements | |||||||||
![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||||||
![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||||||
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||||||
![]() ![]() |
0..* | Identifier | Instance identifier | |||||||||
![]() ![]() |
0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | |||||||||
![]() ![]() |
Σ | 0..* | BackboneElement | Unique Device Identifier (UDI) carrier. See IPS Device profile description for more detail and mapping link. | ||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||
![]() ![]() ![]() |
Σ | 0..1 | string | Mandatory fixed portion of UDI | ||||||||
![]() ![]() ![]() |
0..1 | uri | UDI Issuing Organization | |||||||||
![]() ![]() ![]() |
0..1 | uri | Regional UDI authority | |||||||||
![]() ![]() ![]() |
Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||||||
![]() ![]() ![]() |
Σ | 0..1 | string | UDI Human Readable Barcode String | ||||||||
![]() ![]() ![]() |
0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||||||
![]() ![]() |
?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||||||
![]() ![]() |
0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||||||
![]() ![]() |
0..1 | string | The distinct identification string | |||||||||
![]() ![]() |
0..1 | string | Name of device manufacturer | |||||||||
![]() ![]() |
0..1 | dateTime | Date when the device was made | |||||||||
![]() ![]() |
0..1 | dateTime | Date and time of expiry of this device (if applicable) | |||||||||
![]() ![]() |
0..1 | string | Lot number of manufacture | |||||||||
![]() ![]() |
0..1 | string | Serial number assigned by the manufacturer | |||||||||
![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer | |||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||
![]() ![]() ![]() |
1..1 | string | The name of the device | |||||||||
![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||||||
![]() ![]() |
0..1 | string | The model number for the device | |||||||||
![]() ![]() |
0..1 | string | The part number of the device | |||||||||
![]() ![]() |
SO | 0..1 | CodeableConceptIPS | Type of device. Binding: Medical Devices - IPS (preferred): The type of device or a code for absent/unknown device
| ||||||||
![]() ![]() |
0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||
![]() ![]() ![]() |
1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||||||
![]() ![]() ![]() |
0..1 | string | The version of the standard that is used to operate and communicate | |||||||||
![]() ![]() |
0..* | BackboneElement | The actual design of the device or software version running on the device | |||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||
![]() ![]() ![]() |
0..1 | CodeableConcept | The type of the device version | |||||||||
![]() ![]() ![]() |
0..1 | Identifier | A single component of the device version | |||||||||
![]() ![]() ![]() |
1..1 | string | The version text | |||||||||
![]() ![]() |
0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | |||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||
![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||||||
![]() ![]() ![]() |
0..* | Quantity | Property value as a quantity | |||||||||
![]() ![]() ![]() |
0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||||||
![]() ![]() |
0..1 | Reference(Patient) | Patient to whom Device is affixed | |||||||||
![]() ![]() |
0..1 | Reference(Organization) | Organization responsible for device | |||||||||
![]() ![]() |
0..* | ContactPoint | Details for human/organization for support | |||||||||
![]() ![]() |
0..1 | Reference(Location) | Where the device is found | |||||||||
![]() ![]() |
0..1 | uri | Network address to contact device | |||||||||
![]() ![]() |
0..* | Annotation | Device notes and comments | |||||||||
![]() ![]() |
Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||||||
![]() ![]() |
0..1 | Reference(Device) | The parent device | |||||||||
Documentation for this format | ||||||||||||
| Name | Creator (IPS) | Consumer (IPS)![]() |
|---|---|---|
![]() |
||
![]() ![]() |
|
|
Documentation for this format | ||
| Path | Status | Usage | ValueSet | Version | Source |
| Device.language | Base | preferred | Common Languages | 📍4.0.1 | FHIR Std. |
| Device.udiCarrier.entryType | Base | required | UDIEntryType | 📍4.0.1 | FHIR Std. |
| Device.status | Base | required | FHIRDeviceStatus | 📍4.0.1 | FHIR Std. |
| Device.statusReason | Base | extensible | FHIRDeviceStatusReason | 📍4.0.1 | FHIR Std. |
| Device.deviceName.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| Device.type | Base | preferred | Medical Devices - IPS | 📦2.0.0 | This IG |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Device | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
Summary
Must-Support: 1 element
Structures
This structure refers to these other structures:
Maturity: 3
Other representations of profile: CSV, Excel, Schematron