Breast Imaging Reporting - 2nd STU ballot, published by HL7 International - Clinical Interoperability Council. This is not an authorized publication; it is the continuous build for version 0.3.0). This version is based on the current content of https://github.com/HL7/fhir-breast-radiology-ig/ and changes regularly. See the Directory of published versions
Official URL: http://hl7.org/fhir/us/breast-radiology/StructureDefinition/ConsistentWith | Version: 0.3.0 | |||
Active as of 2022-12-07 | Computable Name: ConsistentWith |
Consistent With
Description
'Consistent With' Observation
This resource contains information about a determination that the parent abnormality is consistent with the finding described in this resource.
Graphical Overview
This graph provides an overview of this profile, and its dependencies.
Click on any of the elements of the graph to go to a section describing that element.
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from USCoreObservationImagingResultProfile
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | 0..* | USCoreObservationImagingResultProfile | Measurements and simple assertions | |
contained | 0..0 | |||
basedOn | 0..0 | |||
partOf | 0..0 | |||
Slices for category | 2..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by pattern:$this | |
category:categoryImaging | 1..1 | CodeableConcept | Classification of type of observation Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: imaging | |
code | 1..1 | CodeableConcept | Imaging Name Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/breast-radiology/CodeSystem/ObservationCodesCS | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: consistentWithObservation | |
focus | 0..0 | |||
value[x] | 0..0 | |||
dataAbsentReason | 0..0 | |||
interpretation | 0..0 | |||
specimen | 0..0 | |||
device | 0..0 | |||
referenceRange | 0..0 | |||
hasMember | 0..0 | |||
Slices for component | 1..* | BackboneElement | Component results Slice: Unordered, Open by pattern:code | |
component:consistentWith | 1..1 | BackboneElement | Consistent With component. | |
code | 1..1 | CodeableConcept | Consistent With component code. Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/breast-radiology/CodeSystem/ObservationComponentSliceCodesCS | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: consistentWithValue | |
value[x] | 1..1 | CodeableConcept | Actual component result Binding: ConsistentWith ValueSet (required) | |
component:qualifier | 0..* | BackboneElement | Consistent With Qualifier component. | |
code | 1..1 | CodeableConcept | Consistent With Qualifier component code. Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/breast-radiology/CodeSystem/ObservationComponentSliceCodesCS | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: consistentWithQualifier | |
value[x] | 0..1 | CodeableConcept | Actual component result Binding: ConsistentWith Qualifier ValueSet (required) | |
Documentation for this format |
Path | Conformance | ValueSet |
Observation.component:consistentWith.value[x] | required | ConsistentWithVS |
Observation.component:qualifier.value[x] | required | ConsistentWithQualifierVS (a valid code from ConsistentWith Qualifier CodeSystem) |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | USCoreObservationImagingResultProfile | Measurements and simple assertions |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. |
Slices for category | S | 2..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by pattern:$this Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
category:imaging | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: imaging | |
category:categoryImaging | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: imaging | |
code | SΣ | 1..1 | CodeableConcept | Imaging Name Binding: US Core Non Laboratory Codes (extensible) Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/breast-radiology/CodeSystem/ObservationCodesCS | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: consistentWithObservation | |
subject | SΣ | 1..1 | Reference(US Core Patient Profile) | Who and/or what the observation is about |
effective[x] | SΣC | 0..1 | Clinically relevant time/time-period for observation | |
effectiveDateTime | dateTime | |||
Slices for component | Σ | 1..* | BackboneElement | Component results Slice: Unordered, Open by pattern:code |
component:All Slices | Content/Rules for all slices | |||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. |
component:consistentWith | Σ | 1..1 | BackboneElement | Consistent With component. |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | Σ | 1..1 | CodeableConcept | Consistent With component code. Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/breast-radiology/CodeSystem/ObservationComponentSliceCodesCS | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: consistentWithValue | |
value[x] | Σ | 1..1 | CodeableConcept | Actual component result Binding: ConsistentWith ValueSet (required) |
component:qualifier | Σ | 0..* | BackboneElement | Consistent With Qualifier component. |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | Σ | 1..1 | CodeableConcept | Consistent With Qualifier component code. Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/breast-radiology/CodeSystem/ObservationComponentSliceCodesCS | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: consistentWithQualifier | |
value[x] | Σ | 0..1 | CodeableConcept | Actual component result Binding: ConsistentWith Qualifier ValueSet (required) |
Documentation for this format |
Path | Conformance | ValueSet / Code |
Observation.status | required | ObservationStatus |
Observation.category | preferred | ObservationCategoryCodes |
Observation.category:imaging | preferred | Pattern: imaging |
Observation.category:categoryImaging | preferred | Pattern: imaging |
Observation.code | extensible | Pattern: consistentWithObservation |
Observation.component.code | example | LOINCCodes (a valid code from LOINC) |
Observation.component:consistentWith.code | example | Pattern: consistentWithValue |
Observation.component:consistentWith.value[x] | required | ConsistentWithVS |
Observation.component:qualifier.code | example | Pattern: consistentWithQualifier |
Observation.component:qualifier.value[x] | required | ConsistentWithQualifierVS (a valid code from ConsistentWith Qualifier CodeSystem) |
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | USCoreObservationImagingResultProfile | Measurements and simple assertions | ||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | ||||
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. | ||||
Slices for category | S | 2..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by pattern:$this Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
category:imaging | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following | ||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: imaging | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
category:categoryImaging | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following | ||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: imaging | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
code | SΣ | 1..1 | CodeableConcept | Imaging Name Binding: US Core Non Laboratory Codes (extensible) Required Pattern: At least the following | ||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/breast-radiology/CodeSystem/ObservationCodesCS | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: consistentWithObservation | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
subject | SΣ | 1..1 | Reference(US Core Patient Profile) | Who and/or what the observation is about | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
effective[x] | SΣC | 0..1 | Clinically relevant time/time-period for observation | |||||
effectiveDateTime | dateTime S | |||||||
effectivePeriod | Period | |||||||
effectiveTiming | Timing | |||||||
effectiveInstant | instant | |||||||
issued | Σ | 0..1 | instant | Date/Time this version was made available | ||||
performer | Σ | 0..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation | ||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |||||
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | |||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) | Related measurements the observation is made from | ||||
Slices for component | Σ | 1..* | BackboneElement | Component results Slice: Unordered, Open by pattern:code | ||||
component:All Slices | Content/Rules for all slices | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. | ||||
value[x] | Σ | 0..1 | Actual component result | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:consistentWith | Σ | 1..1 | BackboneElement | Consistent With component. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | Σ | 1..1 | CodeableConcept | Consistent With component code. Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following | ||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/breast-radiology/CodeSystem/ObservationComponentSliceCodesCS | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: consistentWithValue | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
value[x] | Σ | 1..1 | CodeableConcept | Actual component result Binding: ConsistentWith ValueSet (required) | ||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:qualifier | Σ | 0..* | BackboneElement | Consistent With Qualifier component. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | Σ | 1..1 | CodeableConcept | Consistent With Qualifier component code. Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following | ||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/breast-radiology/CodeSystem/ObservationComponentSliceCodesCS | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: consistentWithQualifier | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
value[x] | Σ | 0..1 | CodeableConcept | Actual component result Binding: ConsistentWith Qualifier ValueSet (required) | ||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format |
Path | Conformance | ValueSet / Code | ||||
Observation.language | preferred | CommonLanguages
| ||||
Observation.status | required | ObservationStatus | ||||
Observation.category | preferred | ObservationCategoryCodes | ||||
Observation.category:imaging | preferred | Pattern: imaging | ||||
Observation.category:categoryImaging | preferred | Pattern: imaging | ||||
Observation.code | extensible | Pattern: consistentWithObservation | ||||
Observation.bodySite | example | SNOMEDCTBodyStructures | ||||
Observation.method | example | ObservationMethods | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodes | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodes | ||||
Observation.component.code | example | LOINCCodes (a valid code from LOINC) | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodes | ||||
Observation.component:consistentWith.code | example | Pattern: consistentWithValue | ||||
Observation.component:consistentWith.value[x] | required | ConsistentWithVS | ||||
Observation.component:consistentWith.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.component:consistentWith.interpretation | extensible | ObservationInterpretationCodes | ||||
Observation.component:qualifier.code | example | Pattern: consistentWithQualifier | ||||
Observation.component:qualifier.value[x] | required | ConsistentWithQualifierVS (a valid code from ConsistentWith Qualifier CodeSystem) | ||||
Observation.component:qualifier.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.component:qualifier.interpretation | extensible | ObservationInterpretationCodes |
This structure is derived from USCoreObservationImagingResultProfile
Summary
Mandatory: 4 elements
Prohibited: 11 elements
Slices
This structure defines the following Slices:
Differential View
This structure is derived from USCoreObservationImagingResultProfile
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | 0..* | USCoreObservationImagingResultProfile | Measurements and simple assertions | |
contained | 0..0 | |||
basedOn | 0..0 | |||
partOf | 0..0 | |||
Slices for category | 2..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by pattern:$this | |
category:categoryImaging | 1..1 | CodeableConcept | Classification of type of observation Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: imaging | |
code | 1..1 | CodeableConcept | Imaging Name Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/breast-radiology/CodeSystem/ObservationCodesCS | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: consistentWithObservation | |
focus | 0..0 | |||
value[x] | 0..0 | |||
dataAbsentReason | 0..0 | |||
interpretation | 0..0 | |||
specimen | 0..0 | |||
device | 0..0 | |||
referenceRange | 0..0 | |||
hasMember | 0..0 | |||
Slices for component | 1..* | BackboneElement | Component results Slice: Unordered, Open by pattern:code | |
component:consistentWith | 1..1 | BackboneElement | Consistent With component. | |
code | 1..1 | CodeableConcept | Consistent With component code. Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/breast-radiology/CodeSystem/ObservationComponentSliceCodesCS | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: consistentWithValue | |
value[x] | 1..1 | CodeableConcept | Actual component result Binding: ConsistentWith ValueSet (required) | |
component:qualifier | 0..* | BackboneElement | Consistent With Qualifier component. | |
code | 1..1 | CodeableConcept | Consistent With Qualifier component code. Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/breast-radiology/CodeSystem/ObservationComponentSliceCodesCS | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: consistentWithQualifier | |
value[x] | 0..1 | CodeableConcept | Actual component result Binding: ConsistentWith Qualifier ValueSet (required) | |
Documentation for this format |
Path | Conformance | ValueSet |
Observation.component:consistentWith.value[x] | required | ConsistentWithVS |
Observation.component:qualifier.value[x] | required | ConsistentWithQualifierVS (a valid code from ConsistentWith Qualifier CodeSystem) |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | USCoreObservationImagingResultProfile | Measurements and simple assertions |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. |
Slices for category | S | 2..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by pattern:$this Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
category:imaging | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: imaging | |
category:categoryImaging | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: imaging | |
code | SΣ | 1..1 | CodeableConcept | Imaging Name Binding: US Core Non Laboratory Codes (extensible) Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/breast-radiology/CodeSystem/ObservationCodesCS | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: consistentWithObservation | |
subject | SΣ | 1..1 | Reference(US Core Patient Profile) | Who and/or what the observation is about |
effective[x] | SΣC | 0..1 | Clinically relevant time/time-period for observation | |
effectiveDateTime | dateTime | |||
Slices for component | Σ | 1..* | BackboneElement | Component results Slice: Unordered, Open by pattern:code |
component:All Slices | Content/Rules for all slices | |||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. |
component:consistentWith | Σ | 1..1 | BackboneElement | Consistent With component. |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | Σ | 1..1 | CodeableConcept | Consistent With component code. Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/breast-radiology/CodeSystem/ObservationComponentSliceCodesCS | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: consistentWithValue | |
value[x] | Σ | 1..1 | CodeableConcept | Actual component result Binding: ConsistentWith ValueSet (required) |
component:qualifier | Σ | 0..* | BackboneElement | Consistent With Qualifier component. |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | Σ | 1..1 | CodeableConcept | Consistent With Qualifier component code. Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/breast-radiology/CodeSystem/ObservationComponentSliceCodesCS | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: consistentWithQualifier | |
value[x] | Σ | 0..1 | CodeableConcept | Actual component result Binding: ConsistentWith Qualifier ValueSet (required) |
Documentation for this format |
Path | Conformance | ValueSet / Code |
Observation.status | required | ObservationStatus |
Observation.category | preferred | ObservationCategoryCodes |
Observation.category:imaging | preferred | Pattern: imaging |
Observation.category:categoryImaging | preferred | Pattern: imaging |
Observation.code | extensible | Pattern: consistentWithObservation |
Observation.component.code | example | LOINCCodes (a valid code from LOINC) |
Observation.component:consistentWith.code | example | Pattern: consistentWithValue |
Observation.component:consistentWith.value[x] | required | ConsistentWithVS |
Observation.component:qualifier.code | example | Pattern: consistentWithQualifier |
Observation.component:qualifier.value[x] | required | ConsistentWithQualifierVS (a valid code from ConsistentWith Qualifier CodeSystem) |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | USCoreObservationImagingResultProfile | Measurements and simple assertions | ||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | ||||
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. | ||||
Slices for category | S | 2..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by pattern:$this Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
category:imaging | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following | ||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: imaging | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
category:categoryImaging | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following | ||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: imaging | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
code | SΣ | 1..1 | CodeableConcept | Imaging Name Binding: US Core Non Laboratory Codes (extensible) Required Pattern: At least the following | ||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/breast-radiology/CodeSystem/ObservationCodesCS | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: consistentWithObservation | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
subject | SΣ | 1..1 | Reference(US Core Patient Profile) | Who and/or what the observation is about | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
effective[x] | SΣC | 0..1 | Clinically relevant time/time-period for observation | |||||
effectiveDateTime | dateTime S | |||||||
effectivePeriod | Period | |||||||
effectiveTiming | Timing | |||||||
effectiveInstant | instant | |||||||
issued | Σ | 0..1 | instant | Date/Time this version was made available | ||||
performer | Σ | 0..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation | ||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |||||
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | |||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) | Related measurements the observation is made from | ||||
Slices for component | Σ | 1..* | BackboneElement | Component results Slice: Unordered, Open by pattern:code | ||||
component:All Slices | Content/Rules for all slices | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. | ||||
value[x] | Σ | 0..1 | Actual component result | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:consistentWith | Σ | 1..1 | BackboneElement | Consistent With component. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | Σ | 1..1 | CodeableConcept | Consistent With component code. Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following | ||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/breast-radiology/CodeSystem/ObservationComponentSliceCodesCS | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: consistentWithValue | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
value[x] | Σ | 1..1 | CodeableConcept | Actual component result Binding: ConsistentWith ValueSet (required) | ||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:qualifier | Σ | 0..* | BackboneElement | Consistent With Qualifier component. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | Σ | 1..1 | CodeableConcept | Consistent With Qualifier component code. Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following | ||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/breast-radiology/CodeSystem/ObservationComponentSliceCodesCS | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: consistentWithQualifier | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
value[x] | Σ | 0..1 | CodeableConcept | Actual component result Binding: ConsistentWith Qualifier ValueSet (required) | ||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format |
Path | Conformance | ValueSet / Code | ||||
Observation.language | preferred | CommonLanguages
| ||||
Observation.status | required | ObservationStatus | ||||
Observation.category | preferred | ObservationCategoryCodes | ||||
Observation.category:imaging | preferred | Pattern: imaging | ||||
Observation.category:categoryImaging | preferred | Pattern: imaging | ||||
Observation.code | extensible | Pattern: consistentWithObservation | ||||
Observation.bodySite | example | SNOMEDCTBodyStructures | ||||
Observation.method | example | ObservationMethods | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodes | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodes | ||||
Observation.component.code | example | LOINCCodes (a valid code from LOINC) | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodes | ||||
Observation.component:consistentWith.code | example | Pattern: consistentWithValue | ||||
Observation.component:consistentWith.value[x] | required | ConsistentWithVS | ||||
Observation.component:consistentWith.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.component:consistentWith.interpretation | extensible | ObservationInterpretationCodes | ||||
Observation.component:qualifier.code | example | Pattern: consistentWithQualifier | ||||
Observation.component:qualifier.value[x] | required | ConsistentWithQualifierVS (a valid code from ConsistentWith Qualifier CodeSystem) | ||||
Observation.component:qualifier.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.component:qualifier.interpretation | extensible | ObservationInterpretationCodes |
This structure is derived from USCoreObservationImagingResultProfile
Summary
Mandatory: 4 elements
Prohibited: 11 elements
Slices
This structure defines the following Slices:
Other representations of profile: CSV, Excel, Schematron