CardX Hypertension Management Use Case, published by Clinical Interoperability Council. This is not an authorized publication; it is the continuous build for version 0.1.0). This version is based on the current content of https://github.com/HL7/cardx-ig/ and changes regularly. See the Directory of published versions
{
"resourceType" : "Device",
"id" : "phd-bloodpressuremonitor-MS",
"meta" : {
"profile" : [
"http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice"
]
},
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"phd-bloodpressuremonitor-MS\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device "phd-bloodpressuremonitor-MS" </p><p style=\"margin-bottom: 0px\">Profile: <code>http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice</code></p></div><p><b>identifier</b>: SYSID: 71-10-00-FE-FF-5F-49-B0, BTMAC: B0-49-5F-00-10-71</p><p><b>manufacturer</b>: OMRONHEALTHCARE</p><p><b>serialNumber</b>: 20150200002A</p><p><b>modelNumber</b>: HEM-9200T</p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.0.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#65573)</span></p><h3>Specializations</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>SystemType</b></td><td><b>Version</b></td></tr><tr><td style=\"display: none\">*</td><td>MDC_DEV_SPEC_PROFILE_BP: Blood Pressure Cuff <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.0.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#528391)</span></td><td>1</td></tr></table><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.0.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531976)</span></p><p><b>value</b>: C.00.7AJ-02</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.0.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531975)</span></p><p><b>value</b>: 0000000000000101</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_HW: Hardware revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.0.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531974)</span></p><p><b>value</b>: 0000000000000100</p></blockquote><h3>Properties</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Type</b></td><td><b>ValueCode</b></td></tr><tr><td style=\"display: none\">*</td><td>MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.0.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#68220)</span></td><td>MDC_TIME_SYNC_NONE: <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.0.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532224)</span></td></tr></table></div>"
},
"identifier" : [
{
"type" : {
"coding" : [
{
"system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers",
"code" : "SYSID"
}
]
},
"system" : "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680",
"value" : "71-10-00-FE-FF-5F-49-B0"
},
{
"type" : {
"coding" : [
{
"system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers",
"code" : "BTMAC"
}
]
},
"system" : "http://hl7.org/fhir/sid/eui-48/bluetooth",
"value" : "B0-49-5F-00-10-71"
}
],
"manufacturer" : "OMRONHEALTHCARE",
"serialNumber" : "20150200002A",
"modelNumber" : "HEM-9200T",
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "65573"
}
],
"text" : "MDC_MOC_VMS_MDS_SIMP"
},
"specialization" : [
{
"systemType" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "528391"
}
],
"text" : "MDC_DEV_SPEC_PROFILE_BP: Blood Pressure Cuff"
},
"version" : "1"
}
],
"version" : [
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "531976"
}
],
"text" : "MDC_ID_PROD_SPEC_FW: Firmware revision"
},
"value" : "C.00.7AJ-02"
},
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "531975"
}
],
"text" : "MDC_ID_PROD_SPEC_SW: Software revision"
},
"value" : "0000000000000101"
},
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "531974"
}
],
"text" : "MDC_ID_PROD_SPEC_HW: Hardware revision"
},
"value" : "0000000000000100"
}
],
"property" : [
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "68220"
}
],
"text" : "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"
},
"valueCode" : [
{
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532224"
}
],
"text" : "MDC_TIME_SYNC_NONE:"
}
]
}
]
}
IG © 2022+ Clinical Interoperability Council. Package hl7.fhir.us.cardx-htn#0.1.0 based on FHIR 4.0.1. Generated 2023-08-03