Systolic BP |
1..1 MS |
The value of systolic BP measurement. |
Pattern: LOINC code 96608-5 |
Diastolic BP |
0..1 MS |
The value of diastolic BP measurement. |
Pattern: LOINC code 96609-3 |
Mean Arterial Pressure |
0..1 MS |
The calculated observation based on the Systolic and Diastolic blood pressure measurements and is defined as the average pressure in an individual’s arteries during one cardiac cycle. |
Pattern: LOINC code 8478-0 |
Effective Date/Time Range |
1..1 MS |
The date and time ranges the BP measurement average was calculated from. |
dateTime data type |
Body Site |
0..1 |
The anatomical location where the device was placed. |
TBD |
Observation Category |
1..* |
A code that classifies the general type of observation being made. |
ObservationCategoryCodes |
Method |
0..1 |
Indicates the mechanism used to perform the observation. |
TBD |
Status |
1..1 |
The status of the result value. |
ObservationStatus |
Reference: Device |
0..1 |
Defines the type of device used when measuring the BP. |
TBD |
Measurement Setting |
0..1 |
Environment in which the BP measurement was taken. |
TBD |
Body Position |
0..1 |
The position of the body when the observation was done, e.g. standing, sitting. To be used only when the body position in not precoordinated in the observation code. |
TBD |
Minimum Systolic Blood Pressure |
0..1 |
Of the associated readings what was the minimum. |
TBD |
Minimum Diastolic Blood Pressure |
0..1 |
Of the associated readings what was the minimum. |
TBD |
Maximum Systolic Blood Pressure |
0..1 |
Of the associated readings what was the max. |
TBD |
Maximum Diastolic Blood Pressure |
0..1 |
Of the associated readings what was the max. |
TBD |
Extension: Measurement Protocol |
0..1 |
Rules and algorithm for Average Blood Pressure calculation. |
Measurement Setting value set (extensible) |