US Core Implementation Guide, published by HL7 International / Cross-Group Projects. This guide is not an authorized publication; it is the continuous build for version 7.0.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/US-Core/ and changes regularly. See the Directory of published versions
Page standards status: Informative |
Generated Narrative: Observation
Resource Observation "satO2-fiO2"
Profile: US Core Pulse Oximetry Profile (version 7.0.0-ballot)
identifier: id: o1223435-10
status: final
category: Vital Signs (Observation Category Codes#vital-signs)
code: Oxygen saturation in Arterial blood (LOINC#2708-6; LOINC#59408-5 "Oxygen saturation in Arterial blood by Pulse oximetry"; ISO 11073-10101 Health informatics - Point-of-care#150456 "MDC_PULS_OXIM_SAT_O2")
subject: Patient/example " SHAW"
effective: 2014-12-05 09:30:10+0100
value: 95 % (Details: UCUM code % = '%')
interpretation: Normal (ObservationInterpretation#N)
device: : Acme Pulse Oximeter 2000
Low | High |
90 % (Details: UCUM code % = '%') | 99 % (Details: UCUM code % = '%') |
Code | Value[x] |
Inhaled oxygen flow rate (LOINC#3151-8) | 6 liters/min (Details: UCUM code L/min = 'L/min') |