CardX - Cardiac Implantable Electronic Devices, published by HL7 International / Clinical Interoperability Council. This guide is not an authorized publication; it is the continuous build for version 2.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/CardX-CIED/ and changes regularly. See the Directory of published versions
Language: en
Profile: Implantable Device Cardiac Observation (IDCO) Bundle
Bundle uc1ACMEBundle of type collection
Entry 1
Resource Patient:
Language: en
Profile: Patient - CIED Patient Profile
Jim ACME Doe Male, DoB: 1958-01-01 ( http://example.org#ACME1111 (use: official, ))
Contact Detail
- ph: 111-555-4444(Mobile)
- 1234 Main Street Springfield IL 12345 (home)
Entry 2
Resource Device:
Language: en
Profile: Device - Cardiovascular Implantable Electronic Device (CIED)
manufacturer: ACME Devices
serialNumber: uc1ACMEICD
modelNumber: ICDExample1
type: MDC_IDC_ENUM_DEV_TYPE_ICD
Entry 3
Resource Device:
Language: en
Profile: Device - Cardiovascular Implantable Electronic Device (CIED) Lead
manufacturer: ACME Devices
serialNumber: ACMELead
modelNumber: LeadExample1
Entry 4
Resource DeviceAssociation:
Language: en
Profile: Device Association - Cardiovascular Implantable Electronic Device (CIED)
Association Status Extension: Implanted
status: Implanted
subject: Jim ACME Doe Male, DoB: 1958-01-01 ( http://example.org#ACME1111 (use: official, ))
period: 2020-06-01 --> (ongoing)
Entry 5
Resource DeviceAssociation:
Language: en
Profile: Device Association - Cardiovascular Implantable Electronic Device (CIED)
Association Status Extension: Implanted
device: Device: manufacturer = ACME Devices; serialNumber = ACMELead; modelNumber = LeadExample1
status: Implanted
subject: Jim ACME Doe Male, DoB: 1958-01-01 ( http://example.org#ACME1111 (use: official, ))
period: 2020-06-01 --> (ongoing)
Entry 6
Resource DiagnosticReport:
Language: en
Profile: CIED Diagnostic Report Profile
Cardiac electrophysiology procedure note
Subject Jim ACME Doe Male, DoB: 1958-01-01 ( http://example.org#ACME1111 (use: official, )) Relevant Time 2024-01-15 10:30:00-0500 Identifier http://example.org/ACME-DR-001 (use: official, )Report Details
Code Value Flags Implantable Device Cardiac Observation Final
Entry 7
Resource Observation:
Language: en
status: Final
code: Implantable Device Cardiac Observation
component
Instance of repeatable element: 1
code: MDC_IDC_MSMT_BATTERY_DTM
value: 2019-10-16 12:12:29-0900
component
Instance of repeatable element: 1
code: MDC_IDC_MSMT_BATTERY_STATUS
value: MDC_IDC_ENUM_BATTERY_STATUS_BOS
component
Instance of repeatable element: 1
code: MDC_IDC_MSMT_BATTERY_VOLTAGE
value: 6.2 V (Details: UCUM codeV = 'V')
component
Instance of repeatable element: 1
code: MDC_IDC_MSMT_BATTERY_IMPEDANCE
value: 2450 Ohm (Details: UCUM codeOhm = 'Ohm')
component
Instance of repeatable element: 1
code: MDC_IDC_MSMT_BATTERY_REMAINING_LONGEVITY
value: 38 mo (Details: UCUM codemo = 'mo')
component
Instance of repeatable element: 1
code: MDC_IDC_MSMT_BATTERY_REMAINING_PERCENTAGE
value: 75 % (Details: UCUM code% = '%')
component
Instance of repeatable element: 1
code: MDC_IDC_MSMT_BATTERY_RRT_TRIGGER
value: Battery capacity < limit for 3 months
component
Instance of repeatable element: 1
code: MDC_IDC_MSMT_BATTERY_REMAINING_LONGEVITY_TIMEFRAME
value: MDC_IDC_ENUM_BATTERY_STATUS_RRT
component
Instance of repeatable element: 1
code: MDC_IDC_MSMT_BATTERY_REMAINING_PERCENTAGE_TIMEFRAME
value: MDC_IDC_ENUM_BATTERY_STATUS_RRT
component
Instance of repeatable element: 1
code: MDC_IDC_MSMT_BATTERY_RRT_REACHED_DTM
value: 2025-03-21 12:12:29-0900
component
code: MDC_IDC_MSMT_CAP_CHARGE_DTM
value: 2018-03-21 12:12:29-0900
component
code: MDC_IDC_MSMT_CAP_CHARGE_TIME
value: 9.4 s (Details: UCUM codes = 's')
component
code: MDC_IDC_MSMT_CAP_CHARGE_ENERGY
value: 30 J (Details: UCUM codeJ = 'J')
component
code: MDC_IDC_MSMT_CAP_CHARGE_TYPE
value: MDC_IDC_ENUM_CHARGE_TYPE_Shock
component
code: MDC_IDC_MSMT_LEADCHNL_RA_DTM_START
value: 2019-03-21 12:12:29-0900
component
code: MDC_IDC_MSMT_LEADCHNL_RA_DTM_END
value: 2020-03-21 12:12:29-0900
component
code: MDC_IDC_MSMT_LEADCHNL_RA_LEAD_CHANNEL_STATUS
value: MDC_IDC_ENUM_CHANNEL_STATUS_CheckLead
component
code: MDC_IDC_MSMT_LEADCHNL_RA_SENSING_INTR_AMPL_MAX
value: 2.6 mV (Details: UCUM codemV = 'mV')
component
code: MDC_IDC_MSMT_LEADCHNL_RA_SENSING_INTR_AMPL_MIN
value: 2.2 mV (Details: UCUM codemV = 'mV')
component
code: MDC_IDC_MSMT_LEADCHNL_RA_SENSING_INTR_AMPL_MEAN
value: 2.5 mV (Details: UCUM codemV = 'mV')
component
code: MDC_IDC_MSMT_LEADCHNL_RA_SENSING_POLARITY
value: MDC_IDC_ENUM_POLARITY_UNI
component
code: MDC_IDC_MSMT_LEADCHNL_RA_PACING_THRESHOLD_AMPLITUDE
value: 0.7 V (Details: UCUM codeV = 'V')
component
code: MDC_IDC_MSMT_LEADCHNL_RA_PACING_THRESHOLD_PULSEWIDTH
value: 0.5 ms (Details: UCUM codems = 'ms')
component
code: MDC_IDC_MSMT_LEADCHNL_RA_PACING_THRESHOLD_MEASUREMENT_METHOD
value: MDC_IDC_ENUM_MEASUREMENT_METHOD_DeviceAutomatic
component
code: MDC_IDC_MSMT_LEADCHNL_RA_PACING_THRESHOLD_POLARITY
value: MDC_IDC_ENUM_POLARITY_BI
component
code: MDC_IDC_MSMT_LEADCHNL_RA_IMPEDANCE_VALUE
value: 530 Ohm (Details: UCUM codeOhm = 'Ohm')
component
code: MDC_IDC_MSMT_LEADCHNL_RA_IMPEDANCE_POLARITY
value: MDC_IDC_ENUM_POLARITY_BI
component
code: MDC_IDC_SET_TACHYTHERAPY_VSTAT
value: MDC_IDC_ENUM_THERAPY_STATUS_On
component
Instance of repeatable element: 1
code: MDC_IDC_SET_ZONE_TYPE
value: MDC_IDC_ENUM_ZONE_TYPE_Zone_VF
component
Instance of repeatable element: 1
code: MDC_IDC_SET_ZONE_VENDOR_TYPE
value: MDC_IDC_ENUM_ZONE_VENDOR_TYPE_MDT-Zone_VF
component
Instance of repeatable element: 1
code: MDC_IDC_SET_ZONE_STATUS
value: MDC_IDC_ENUM_ZONE_STATUS_Active
component
Instance of repeatable element: 1
code: MDC_IDC_SET_ZONE_DETECTION_INTERVAL
value: 300 ms (Details: UCUM codems = 'ms')
component
Instance of repeatable element: 1
code: MDC_IDC_SET_ZONE_TYPE_ATP_1
value: MDC_IDC_ENUM_ATP_TYPE_Burst
component
Instance of repeatable element: 1
code: MDC_IDC_SET_ZONE_TYPE_ATP_1
value: MDC_IDC_ENUM_ATP_TYPE_Burst
component
Instance of repeatable element: 1
code: MDC_IDC_SET_ZONE_NUM_ATP_SEQS_1
value: 1
component
Instance of repeatable element: 1
code: MDC_IDC_SET_ZONE_SHOCK_ENERGY_1
value: 0.6 J (Details: UCUM codeJ = 'J')
component
Instance of repeatable element: 1
code: MDC_IDC_SET_ZONE_NUM_SHOCKS_1
value: 1
component
Instance of repeatable element: 1
code: MDC_IDC_SET_ZONE_SHOCK_ENERGY_2
value: 0.6 J (Details: UCUM codeJ = 'J')
component
Instance of repeatable element: 1
code: MDC_IDC_SET_ZONE_NUM_SHOCKS_2
value: 1
component
Instance of repeatable element: 1
code: MDC_IDC_SET_ZONE_SHOCK_ENERGY_3
value: 41 J (Details: UCUM codeJ = 'J')
component
Instance of repeatable element: 1
code: MDC_IDC_SET_ZONE_NUM_SHOCKS_3
value: 1
component
Instance of repeatable element: 2
code: MDC_IDC_SET_ZONE_TYPE
value: MDC_IDC_ENUM_ZONE_TYPE_Zone_VT
component
Instance of repeatable element: 2
code: MDC_IDC_SET_ZONE_VENDOR_TYPE
value: MDC_IDC_ENUM_ZONE_VENDOR_TYPE_MDT-Zone_VF
component
Instance of repeatable element: 2
code: MDC_IDC_SET_ZONE_STATUS
value: MDC_IDC_ENUM_ZONE_STATUS_Monitor
component
Instance of repeatable element: 2
code: MDC_IDC_SET_ZONE_DETECTION_INTERVAL
value: 375 ms (Details: UCUM codems = 'ms')
Entry 8
Resource Organization:
Language: en
Profile: Organization - Cardiovascular Implantable Electronic Device (CIED)
identifier:
http://example.org/ACME-ORG-001 (use: official, )name: ACME Medical Center
Entry 9
Resource Practitioner:
Language: en
Profile: CIED Practioner Profile
identifier: United States National Provider Identifier/1234567890 (use: official, )
name: Jane Smith
telecom: ph: 555-867-5309(Work)
address: 1234 Main Street Springfield IL 12345 (work)