CardX - Cardiac Implantable Electronic Devices, published by HL7 International / Clinical Interoperability Council. This guide is not an authorized publication; it is the continuous build for version 2.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/CardX-CIED/ and changes regularly. See the Directory of published versions
| Page standards status: Informative |
Language: en
status: Final
code: Implantable Device Cardiac Observation - TEMPORARY CODE.
component
Instance of repeatable element: 1
code: Battery Date Time of Measurements
value: 2019-10-16 12:12:29-0900
component
Instance of repeatable element: 1
code: Battery Status
value: Beginning of Service
component
Instance of repeatable element: 1
code: Battery Voltage
value: 6.2 V (Details: UCUM codeV = 'V')
component
Instance of repeatable element: 1
code: Battery Impedance
value: 2450 Ohm (Details: UCUM codeOhm = 'Ohm')
component
Instance of repeatable element: 1
code: Battery Remaining Longevity
value: 38 mo (Details: UCUM codemo = 'mo')
component
Instance of repeatable element: 1
code: Battery Remaining Percentage
value: 75 % (Details: UCUM code% = '%')
component
Instance of repeatable element: 1
code: Battery RRT Trigger
value: Battery capacity < limit for 3 months
component
Instance of repeatable element: 1
code: Battery Remaining Longevity Timeframe
value: RRT
component
Instance of repeatable element: 1
code: Battery Remaining Percentage Timeframe
value: RRT
component
Instance of repeatable element: 1
code: Battery RRT Reached Date Time
value: 2025-03-21 12:12:29-0900
component
code: Capacitor Last Charge Date Time
value: 2018-03-21 12:12:29-0900
component
code: Capacitor Charge Time
value: 9.4 s (Details: UCUM codes = 's')
component
code: Capacitor Charge Energy
value: 30 J (Details: UCUM codeJ = 'J')
component
code: Capacitor Charge Type
value: Shock
component
code: Lead Channel Measurements Date and Time MDC_IDC_MSMT_LEADCHNL_RA_DTM_START
value: 2019-03-21 12:12:29-0900
component
code: Lead Channel Measurements Date and Time MDC_IDC_MSMT_LEADCHNL_RA_DTM_END
value: 2020-03-21 12:12:29-0900
component
code: Lead Channel Status MDC_IDC_MSMT_LEADCHNL_RA_LEAD_CHANNEL_STATUS
value: Check Lead
component
code: Lead Channel Sensing Intrinsic Amplitude MDC_IDC_MSMT_LEADCHNL_RA_SENSING_INTR_AMPL_MAX
value: 2.6 mV (Details: UCUM codemV = 'mV')
component
code: Lead Channel Sensing Intrinsic Amplitude MDC_IDC_MSMT_LEADCHNL_RA_SENSING_INTR_AMPL_MIN
value: 2.2 mV (Details: UCUM codemV = 'mV')
component
code: Lead Channel Sensing Intrinsic Amplitude MDC_IDC_MSMT_LEADCHNL_RA_SENSING_INTR_AMPL_MEAN
value: 2.5 mV (Details: UCUM codemV = 'mV')
component
code: Lead Channel Sensing Polarity MDC_IDC_MSMT_LEADCHNL_RA_SENSING_POLARITY
value: Unipolar
component
code: Lead Channel Pacing Threshold Amplitude MDC_IDC_MSMT_LEADCHNL_RA_PACING_THRESHOLD_AMPLITUDE
value: 0.7 V (Details: UCUM codeV = 'V')
component
code: Lead Channel Pacing Threshold Pulse Width MDC_IDC_MSMT_LEADCHNL_RA_PACING_THRESHOLD_PULSEWIDTH
value: 0.5 ms (Details: UCUM codems = 'ms')
component
code: Lead Channel Pacing Threshold Measurement Method MDC_IDC_MSMT_LEADCHNL_RA_PACING_THRESHOLD_MEASUREMENT_METHOD
value: Device Automatic
component
code: Lead Channel Pacing Threshold Polarity MDC_IDC_MSMT_LEADCHNL_RA_PACING_THRESHOLD_POLARITY
value: Bipolar
component
code: Lead Channel Impedance Value MDC_IDC_MSMT_LEADCHNL_RA_IMPEDANCE_VALUE
value: 530 Ohm (Details: UCUM codeOhm = 'Ohm')
component
code: Lead Channel Impedance Polarity MDC_IDC_MSMT_LEADCHNL_RA_IMPEDANCE_POLARITY
value: Bipolar
component
code: Tachy Therapy Setting Ventricular Status
value: On
component
Instance of repeatable element: 1
code: Zone Setting Type Category
value: VF
component
Instance of repeatable element: 1
code: Zone Setting Vendor Type Category
value: A Medtronic zone subclassification of ventricular fibrillation.
component
Instance of repeatable element: 1
code: Zone Setting Status
value: Active
component
Instance of repeatable element: 1
code: Zone Setting Detection Interval
value: 300 ms (Details: UCUM codems = 'ms')
component
Instance of repeatable element: 1
code: Zone Setting ATP Type MDC_IDC_SET_ZONE_TYPE_ATP_1
value: Burst
component
Instance of repeatable element: 1
code: Zone Setting ATP Type MDC_IDC_SET_ZONE_TYPE_ATP_1
value: Burst
component
Instance of repeatable element: 1
code: Zone Setting Number of ATP Sequences MDC_IDC_SET_ZONE_NUM_ATP_SEQS_1
value: 1
component
Instance of repeatable element: 1
code: The shock energy delivered at a particular sequence of a zone therapy. MDC_IDC_SET_ZONE_SHOCK_ENERGY_1
value: 0.6 J (Details: UCUM codeJ = 'J')
component
Instance of repeatable element: 1
code: Zone Setting Number of Shocks MDC_IDC_SET_ZONE_NUM_SHOCKS_1
value: 1
component
Instance of repeatable element: 1
code: The shock energy delivered at a particular sequence of a zone therapy. MDC_IDC_SET_ZONE_SHOCK_ENERGY_2
value: 0.6 J (Details: UCUM codeJ = 'J')
component
Instance of repeatable element: 1
code: Zone Setting Number of Shocks MDC_IDC_SET_ZONE_NUM_SHOCKS_2
value: 1
component
Instance of repeatable element: 1
code: The shock energy delivered at a particular sequence of a zone therapy. MDC_IDC_SET_ZONE_SHOCK_ENERGY_3
value: 41 J (Details: UCUM codeJ = 'J')
component
Instance of repeatable element: 1
code: Zone Setting Number of Shocks MDC_IDC_SET_ZONE_NUM_SHOCKS_3
value: 1
component
Instance of repeatable element: 2
code: Zone Setting Type Category
value: VT
component
Instance of repeatable element: 2
code: Zone Setting Vendor Type Category
value: A Medtronic zone subclassification of ventricular fibrillation.
component
Instance of repeatable element: 2
code: Zone Setting Status
value: Monitor
component
Instance of repeatable element: 2
code: Zone Setting Detection Interval
value: 375 ms (Details: UCUM codems = 'ms')