Stated Languages: n/a. IG Resource Lang: en. 32 of 32 (100%) of resources have a language. Population Policy: NONE
Publication Request:
package-id
hl7.fhir.uv.cardx-cied
version
1.0.0
Pub-Mode
working release
status
trial-use
Release-Label
ci-build
Sequence (Group)
STU 1 (current: n/a, others = 'STU 1')
desc
STU 1 for CardX - Cardiac Implantable Electronic Devices, includes managing patient connectivity use case
RelatedIgs
(None Found)
This is not the first publication, so first must not be true
Proposed path for this publication does not start with the canonical URL (http://hl7.org/fhir/uv/cardx-cied vs http://hl7.org/fhir/uv/cardx-cied)
Proposed path for this publication should usually be the canonical with the version or sequence appended and then some kind of label (typically '-snapshot')
This release is not labelled as a milestone or technical correction, so should have a patch version (1.0.0)
Publication request category found (not allowed after first publication
Publication request title found (not allowed after first publication)
Publication request introduction found (not allowed after first publication)
Publication request ci-build found (not allowed after first publication)
The jira specification file appears to be out of date with the versions, artifacts and pages currently defined in the IG. A proposed revised file to be reviewed and, if appropriate, submitted as a pull request against the XML folder in https://github.com/HL7/JIRA-Spec-Artifacts. To see the differences, perform a file compare on 'template/jira-current.xml' (a normalized view of what is in Github) and 'template/jira-new.xml' (reflects current IG content)
en/CapabilityStatement-cied-data-sender.html
information
The html source contains the word 'SHALL' but it is not in a text phrase marked as a conformance clauseCONFORMANCE_STATEMENT_WORD
1
warning
The HTML fragment 'ip-statements.xhtml' is not included anywhere in the produced implementation guide
3
warning
An HTML fragment from the set [dependency-table.xhtml, dependency-table-short.xhtml, dependency-table-nontech.xhtml] is not included anywhere in the produced implementation guide
4
warning
The HTML fragment 'globals-table.xhtml' is not included anywhere in the produced implementation guide
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.32.0 (from https://tx.fhir.org/r5) MSG_DRAFT
Device.type[0].coding[0] (l12/c10)
information
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.32.0 (from https://tx.fhir.org/r5, see log, or see the servers logic) MSG_DRAFT
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.32.0 (from https://tx.fhir.org/r5) MSG_DRAFT
Device.type[0].coding[0] (l12/c10)
information
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.32.0 (from https://tx.fhir.org/r5, see log, or see the servers logic) MSG_DRAFT
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.32.0 (from https://tx.fhir.org/r5) MSG_DRAFT
Device.type[0].coding[0] (l12/c10)
information
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.32.0 (from https://tx.fhir.org/r5, see log, or see the servers logic) MSG_DRAFT
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.32.0 (from https://tx.fhir.org/r5) MSG_DRAFT
Device.type[0].coding[0] (l12/c10)
information
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.32.0 (from https://tx.fhir.org/r5, see log, or see the servers logic) MSG_DRAFT
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.32.0 (from https://tx.fhir.org/r5) MSG_DRAFT
Device.type[0].coding[0] (l12/c10)
information
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.32.0 (from https://tx.fhir.org/r5, see log, or see the servers logic) MSG_DRAFT
The definition for the element 'Observation.category' binds to the value set 'http://hl7.org/fhir/ValueSet/observation-category|5.0.0' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'Observation.referenceRange.type' binds to the value set 'http://hl7.org/fhir/ValueSet/referencerange-meaning|5.0.0' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 from fhir.tx.support.r4#0.32.0 (from https://tx.fhir.org/r5, see log, or see the servers logic) MSG_DRAFT
The display 'Device/monitor setup has not been completed. E.g. pending initial setup or there is no device/monitor association' is not valid in the Code system 'Device/monitor setup has not been completed. E.g. pending initial setup or there is no device/monitor association'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
The display 'Patient has been temporarily removed from the disconnected state. This is not intended to be an actionable status.' is not valid in the Code system 'Patient has been temporarily removed from the disconnected state. This is not intended to be an actionable status.'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
The display 'Patient has been permanently removed from disconnected status.' is not valid in the Code system 'Patient has been permanently removed from disconnected status.'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
The display 'Patient has been unenrolled from remote monitoring or remote monitoring has been discontinued.' is not valid in the Code system 'Patient has been unenrolled from remote monitoring or remote monitoring has been discontinued.'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
The display 'The patient has been transfered to another remote monitoring clinic.' is not valid in the Code system 'The patient has been transfered to another remote monitoring clinic.'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
The display 'Connectivity states are not applicable for this device. E.g. device is not compatible with remote monitoring or requires patient initiated interrogations' is not valid in the Code system 'Connectivity states are not applicable for this device. E.g. device is not compatible with remote monitoring or requires patient initiated interrogations'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
The display 'Communication has been successful within the expected time period.' is not valid in the Code system 'Communication has been successful within the expected time period.'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
The display 'Communication has not occurred within the expected time period.' is not valid in the Code system 'Communication has not occurred within the expected time period.'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
The display 'Standalone device, not intended to provide monitoring while on the go.' is not valid in the Code system 'Standalone device, not intended to provide monitoring while on the go.'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
The display 'App based monitor.' is not valid in the Code system 'App based monitor.'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
The display 'Standalone device, with battery capacity to provide monitoring while on the go.' is not valid in the Code system 'Standalone device, with battery capacity to provide monitoring while on the go.'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
01 Suppressing common warnings and warnings associated with core spec
Reference to deprecated ValueSet http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0 (13 uses)
Reference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0 (16 uses)
The definition for the element 'Device.name.type' binds to the value set 'http://hl7.org/fhir/ValueSet/device-nametype|5.0.0' which is experimental, but this structure is not labeled as experimental (2 uses)
The definition for the element 'Observation.category' binds to the value set 'http://hl7.org/fhir/ValueSet/observation-category' which is experimental, but this structure is not labeled as experimental (0 uses)
The definition for the element 'Observation.referenceRange.type' binds to the value set 'http://hl7.org/fhir/ValueSet/referencerange-meaning' which is experimental, but this structure is not labeled as experimental (0 uses)
02 Supressing warnings related to IG specific terminology. Will work with TSMG post-balloting, prior to implementation
Most code systems defined in HL7 IGs will need to move to THO later during the process. Consider giving this code system a THO URL now (See https://confluence.hl7.org/display/TSMG/Terminology+Play+Book, and/or talk to TSMG) (1 uses)
03 Supressing errors rated to UDI URLs included in core FHIR spec. https://chat.fhir.org/#narrow/channel/179199-devices/topic/Device.20naming.20systems
No definition could be found for URL value 'http://hl7.org/fhir/NamingSystem/gs1-di' (0 uses)
No definition could be found for URL value 'http://hl7.org/fhir/NamingSystem/us-fda-udi' (0 uses)
04 Observations have 1 or more devices generating the information and do not have a performer
Best Practice Recommendation: In general, all observations should have a performer (5 uses)
The definition for the element 'Observation.category' binds to the value set 'http://hl7.org/fhir/ValueSet/observation-category|5.0.0' which is experimental, but this structure is not labeled as experimental
The definition for the element 'Observation.referenceRange.type' binds to the value set 'http://hl7.org/fhir/ValueSet/referencerange-meaning|5.0.0' which is experimental, but this structure is not labeled as experimental
The display 'Device/monitor setup has not been completed. E.g. pending initial setup or there is no device/monitor association' is not valid in the Code system 'Device/monitor setup has not been completed. E.g. pending initial setup or there is no device/monitor association'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
The display 'Patient has been temporarily removed from the disconnected state. This is not intended to be an actionable status.' is not valid in the Code system 'Patient has been temporarily removed from the disconnected state. This is not intended to be an actionable status.'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
The display 'Patient has been permanently removed from disconnected status.' is not valid in the Code system 'Patient has been permanently removed from disconnected status.'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
The display 'Patient has been unenrolled from remote monitoring or remote monitoring has been discontinued.' is not valid in the Code system 'Patient has been unenrolled from remote monitoring or remote monitoring has been discontinued.'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
The display 'The patient has been transfered to another remote monitoring clinic.' is not valid in the Code system 'The patient has been transfered to another remote monitoring clinic.'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
The display 'Connectivity states are not applicable for this device. E.g. device is not compatible with remote monitoring or requires patient initiated interrogations' is not valid in the Code system 'Connectivity states are not applicable for this device. E.g. device is not compatible with remote monitoring or requires patient initiated interrogations'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
The display 'Communication has been successful within the expected time period.' is not valid in the Code system 'Communication has been successful within the expected time period.'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
The display 'Communication has not occurred within the expected time period.' is not valid in the Code system 'Communication has not occurred within the expected time period.'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
The display 'Standalone device, not intended to provide monitoring while on the go.' is not valid in the Code system 'Standalone device, not intended to provide monitoring while on the go.'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
The display 'App based monitor.' is not valid in the Code system 'App based monitor.'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
The display 'Standalone device, with battery capacity to provide monitoring while on the go.' is not valid in the Code system 'Standalone device, with battery capacity to provide monitoring while on the go.'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code