HL7 Czech Base and Core Implementation Guide
0.3.0-ballot - ci-build Czechia flag

HL7 Czech Base and Core Implementation Guide, published by HL7 Czech Republic. This guide is not an authorized publication; it is the continuous build for version 0.3.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7-cz/cz-core/ and changes regularly. See the Directory of published versions

Extension: Source device

Official URL: https://hl7.cz/fhir/core/StructureDefinition/source-device-cz Version: 0.3.0-ballot
Standards status: Draft Maturity Level: 1 Computable Name: SourceDeviceCz

This extension allows describe source if the specimen is not collected directly from the patient but comes from a patient-related object, e.g. a catheter

Context of Use

    This extension may be used on the following element(s)

Usage info

Usages:

  • This Extension is not used by any profiles in this Implementation Guide

You can also check for usages in the FHIR IG Statistics

Formal Views of Extension Content

Description of Profiles, Differentials, Snapshots, and how the XML and JSON presentations work.

This structure is derived from Extension

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Extension 0..* Extension Source device
... extension 0..0
... url 1..1 uri "https://hl7.cz/fhir/core/StructureDefinition/source-device-cz"
... value[x] 0..1 CodeableConcept Value of extension

doco Documentation for this format
NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Extension 0..* Extension Source device
... id 0..1 string Unique id for inter-element referencing
... extension 0..0
... url 1..1 uri "https://hl7.cz/fhir/core/StructureDefinition/source-device-cz"

doco Documentation for this format

This structure is derived from Extension

Summary

Simple Extension with the type CodeableConcept: This extension allows describe source if the specimen is not collected directly from the patient but comes from a patient-related object, e.g. a catheter

Maturity: 1

Differential View

This structure is derived from Extension

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Extension 0..* Extension Source device
... extension 0..0
... url 1..1 uri "https://hl7.cz/fhir/core/StructureDefinition/source-device-cz"
... value[x] 0..1 CodeableConcept Value of extension

doco Documentation for this format

Snapshot View

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Extension 0..* Extension Source device
... id 0..1 string Unique id for inter-element referencing
... extension 0..0
... url 1..1 uri "https://hl7.cz/fhir/core/StructureDefinition/source-device-cz"

doco Documentation for this format

This structure is derived from Extension

Summary

Simple Extension with the type CodeableConcept: This extension allows describe source if the specimen is not collected directly from the patient but comes from a patient-related object, e.g. a catheter

Maturity: 1

 

Other representations of profile: CSV, Excel, Schematron

Constraints

IdGradePath(s)DetailsRequirements
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()