CH EMS (R4)
1.9.0-cibuild - ci-build Switzerland flag

CH EMS (R4), published by IVR Interverband für Rettungswesen. This guide is not an authorized publication; it is the continuous build for version 1.9.0-cibuild built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7ch/ch-ems/ and changes regularly. See the Directory of published versions

Example Observation: 2 GCS Uebergabe

Generated Narrative: Observation 2-GCSUebergabe

status: Final

code: Glasgow coma score total

subject: Anonymous Patient Male, DoB Unknown ( Medical record number)

encounter: Encounter: identifier = urn:oid:2.16.756.5.30.1.9999999999.1#S12345678; status = finished; class = emergency (ActCode#EMER); period = 2016-12-10 --> (ongoing)

effective: 2016-12-10 12:03:00+0100

value: 10 {score} (Details: UCUM code{score} = '{score}')

component

code: Glasgow coma score motor

value: 3 (Flexion to pain)

component

code: Glasgow coma score verbal

value: 4 (Confused)

component

code: Glasgow coma score eye opening

value: 3 (Eye opening to verbal command)