FHIR Orders Exchange (FOE) / Post-Acute Orders (PAO) / (DME-Orders), published by HL7. This is not an authorized publication; it is the continuous build for version 0.2.2). This version is based on the current content of https://github.com/HL7/dme-orders/ and changes regularly. See the Directory of published versions
Official URL: http://hl7.org/fhir/us/dme-orders/StructureDefinition/PAOX-devicerequest | Version: 0.2.2 | |||
Active as of 2023-06-25 | Computable Name: PAOxDeviceRequest |
PAO DeviceRequest Resource Profile
Purpose
Intro
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from DeviceRequest
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() | 0..* | DeviceRequest | Medical device request | |
![]() ![]() ![]() | 1..1 | code | proposal | plan | directive | order | original-order | reflex-order | filler-order | instance-order | option Fixed Value: order | |
![]() ![]() ![]() | S | 0..1 | Reference(US Core Encounter Profile) | Encounter motivating request |
![]() |
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() | 0..* | DeviceRequest | Medical device request | |
![]() ![]() ![]() | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() ![]() | ?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() ![]() | ?!Σ | 0..1 | code | draft | active | on-hold | revoked | completed | entered-in-error | unknown Binding: RequestStatus (required): Codes representing the status of the request. |
![]() ![]() ![]() | ?!Σ | 1..1 | code | proposal | plan | directive | order | original-order | reflex-order | filler-order | instance-order | option Binding: RequestIntent (required): The kind of diagnostic request. Fixed Value: order |
![]() ![]() ![]() | Σ | 1..1 | Device requested Binding: FHIRDeviceTypes (example): Codes for devices that can be requested. | |
![]() ![]() ![]() ![]() | Reference(Device) | |||
![]() ![]() ![]() ![]() | CodeableConcept | |||
![]() ![]() ![]() | Σ | 1..1 | Reference(Patient | Group | Location | Device) | Focus of request |
![]() ![]() ![]() | SΣ | 0..1 | Reference(US Core Encounter Profile) | Encounter motivating request |
![]() |
Path | Conformance | ValueSet / Code |
DeviceRequest.status | required | RequestStatus |
DeviceRequest.intent | required | Fixed Value: order |
DeviceRequest.code[x] | example | FHIRDeviceTypes |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | DeviceRequest | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | DeviceRequest | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | DeviceRequest | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | DeviceRequest | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | DeviceRequest | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
Name | Flags | Card. | Type | Description & Constraints![]() | ||||
---|---|---|---|---|---|---|---|---|
![]() ![]() | 0..* | DeviceRequest | Medical device request | |||||
![]() ![]() ![]() | Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() ![]() | Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() ![]() | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() ![]() | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() ![]() | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
![]() ![]() ![]() | 0..* | Resource | Contained, inline Resources | |||||
![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() ![]() | Σ | 0..* | Identifier | External Request identifier | ||||
![]() ![]() ![]() | Σ | 0..* | canonical(ActivityDefinition | PlanDefinition) | Instantiates FHIR protocol or definition | ||||
![]() ![]() ![]() | Σ | 0..* | uri | Instantiates external protocol or definition | ||||
![]() ![]() ![]() | Σ | 0..* | Reference(Resource) | What request fulfills | ||||
![]() ![]() ![]() | Σ | 0..* | Reference(Resource) | What request replaces | ||||
![]() ![]() ![]() | Σ | 0..1 | Identifier | Identifier of composite request | ||||
![]() ![]() ![]() | ?!Σ | 0..1 | code | draft | active | on-hold | revoked | completed | entered-in-error | unknown Binding: RequestStatus (required): Codes representing the status of the request. | ||||
![]() ![]() ![]() | ?!Σ | 1..1 | code | proposal | plan | directive | order | original-order | reflex-order | filler-order | instance-order | option Binding: RequestIntent (required): The kind of diagnostic request. Fixed Value: order | ||||
![]() ![]() ![]() | Σ | 0..1 | code | routine | urgent | asap | stat Binding: RequestPriority (required): Identifies the level of importance to be assigned to actioning the request. | ||||
![]() ![]() ![]() | Σ | 1..1 | Device requested Binding: FHIRDeviceTypes (example): Codes for devices that can be requested. | |||||
![]() ![]() ![]() ![]() | Reference(Device) | |||||||
![]() ![]() ![]() ![]() | CodeableConcept | |||||||
![]() ![]() ![]() | 0..* | BackboneElement | Device details | |||||
![]() ![]() ![]() ![]() | 0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() | 0..1 | CodeableConcept | Device detail Binding: (unbound) (example): A code that identifies the device detail. | |||||
![]() ![]() ![]() ![]() | 0..1 | Value of detail | ||||||
![]() ![]() ![]() ![]() ![]() | CodeableConcept | |||||||
![]() ![]() ![]() ![]() ![]() | Quantity | |||||||
![]() ![]() ![]() ![]() ![]() | Range | |||||||
![]() ![]() ![]() ![]() ![]() | boolean | |||||||
![]() ![]() ![]() | Σ | 1..1 | Reference(Patient | Group | Location | Device) | Focus of request | ||||
![]() ![]() ![]() | SΣ | 0..1 | Reference(US Core Encounter Profile) | Encounter motivating request | ||||
![]() ![]() ![]() | Σ | 0..1 | Desired time or schedule for use | |||||
![]() ![]() ![]() ![]() | dateTime | |||||||
![]() ![]() ![]() ![]() | Period | |||||||
![]() ![]() ![]() ![]() | Timing | |||||||
![]() ![]() ![]() | Σ | 0..1 | dateTime | When recorded | ||||
![]() ![]() ![]() | Σ | 0..1 | Reference(Device | Practitioner | PractitionerRole | Organization) | Who/what is requesting diagnostics | ||||
![]() ![]() ![]() | Σ | 0..1 | CodeableConcept | Filler role Binding: ParticipantRoles (example): Indicates specific responsibility of an individual within the care team, such as "Primary physician", "Team coordinator", "Caregiver", etc. | ||||
![]() ![]() ![]() | Σ | 0..1 | Reference(Practitioner | PractitionerRole | Organization | CareTeam | HealthcareService | Patient | Device | RelatedPerson) | Requested Filler | ||||
![]() ![]() ![]() | Σ | 0..* | CodeableConcept | Coded Reason for request Binding: Condition/Problem/DiagnosisCodes (example): Diagnosis or problem codes justifying the reason for requesting the device. | ||||
![]() ![]() ![]() | Σ | 0..* | Reference(Condition | Observation | DiagnosticReport | DocumentReference) | Linked Reason for request | ||||
![]() ![]() ![]() | 0..* | Reference(Coverage | ClaimResponse) | Associated insurance coverage | |||||
![]() ![]() ![]() | 0..* | Reference(Resource) | Additional clinical information | |||||
![]() ![]() ![]() | 0..* | Annotation | Notes or comments | |||||
![]() ![]() ![]() | 0..* | Reference(Provenance) | Request provenance | |||||
![]() |
Path | Conformance | ValueSet / Code | ||||
DeviceRequest.language | preferred | CommonLanguages
| ||||
DeviceRequest.status | required | RequestStatus | ||||
DeviceRequest.intent | required | Fixed Value: order | ||||
DeviceRequest.priority | required | RequestPriority | ||||
DeviceRequest.code[x] | example | FHIRDeviceTypes | ||||
DeviceRequest.parameter.code | example | |||||
DeviceRequest.performerType | example | ParticipantRoles | ||||
DeviceRequest.reasonCode | example | Condition/Problem/DiagnosisCodes |
Id | Grade | Path(s) | Details | Requirements |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
This structure is derived from DeviceRequest
Differential View
This structure is derived from DeviceRequest
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() | 0..* | DeviceRequest | Medical device request | |
![]() ![]() ![]() | 1..1 | code | proposal | plan | directive | order | original-order | reflex-order | filler-order | instance-order | option Fixed Value: order | |
![]() ![]() ![]() | S | 0..1 | Reference(US Core Encounter Profile) | Encounter motivating request |
![]() |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() | 0..* | DeviceRequest | Medical device request | |
![]() ![]() ![]() | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() ![]() | ?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() ![]() | ?!Σ | 0..1 | code | draft | active | on-hold | revoked | completed | entered-in-error | unknown Binding: RequestStatus (required): Codes representing the status of the request. |
![]() ![]() ![]() | ?!Σ | 1..1 | code | proposal | plan | directive | order | original-order | reflex-order | filler-order | instance-order | option Binding: RequestIntent (required): The kind of diagnostic request. Fixed Value: order |
![]() ![]() ![]() | Σ | 1..1 | Device requested Binding: FHIRDeviceTypes (example): Codes for devices that can be requested. | |
![]() ![]() ![]() ![]() | Reference(Device) | |||
![]() ![]() ![]() ![]() | CodeableConcept | |||
![]() ![]() ![]() | Σ | 1..1 | Reference(Patient | Group | Location | Device) | Focus of request |
![]() ![]() ![]() | SΣ | 0..1 | Reference(US Core Encounter Profile) | Encounter motivating request |
![]() |
Path | Conformance | ValueSet / Code |
DeviceRequest.status | required | RequestStatus |
DeviceRequest.intent | required | Fixed Value: order |
DeviceRequest.code[x] | example | FHIRDeviceTypes |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | DeviceRequest | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | DeviceRequest | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | DeviceRequest | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | DeviceRequest | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | DeviceRequest | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints![]() | ||||
---|---|---|---|---|---|---|---|---|
![]() ![]() | 0..* | DeviceRequest | Medical device request | |||||
![]() ![]() ![]() | Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() ![]() | Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() ![]() | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() ![]() | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() ![]() | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
![]() ![]() ![]() | 0..* | Resource | Contained, inline Resources | |||||
![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() ![]() | Σ | 0..* | Identifier | External Request identifier | ||||
![]() ![]() ![]() | Σ | 0..* | canonical(ActivityDefinition | PlanDefinition) | Instantiates FHIR protocol or definition | ||||
![]() ![]() ![]() | Σ | 0..* | uri | Instantiates external protocol or definition | ||||
![]() ![]() ![]() | Σ | 0..* | Reference(Resource) | What request fulfills | ||||
![]() ![]() ![]() | Σ | 0..* | Reference(Resource) | What request replaces | ||||
![]() ![]() ![]() | Σ | 0..1 | Identifier | Identifier of composite request | ||||
![]() ![]() ![]() | ?!Σ | 0..1 | code | draft | active | on-hold | revoked | completed | entered-in-error | unknown Binding: RequestStatus (required): Codes representing the status of the request. | ||||
![]() ![]() ![]() | ?!Σ | 1..1 | code | proposal | plan | directive | order | original-order | reflex-order | filler-order | instance-order | option Binding: RequestIntent (required): The kind of diagnostic request. Fixed Value: order | ||||
![]() ![]() ![]() | Σ | 0..1 | code | routine | urgent | asap | stat Binding: RequestPriority (required): Identifies the level of importance to be assigned to actioning the request. | ||||
![]() ![]() ![]() | Σ | 1..1 | Device requested Binding: FHIRDeviceTypes (example): Codes for devices that can be requested. | |||||
![]() ![]() ![]() ![]() | Reference(Device) | |||||||
![]() ![]() ![]() ![]() | CodeableConcept | |||||||
![]() ![]() ![]() | 0..* | BackboneElement | Device details | |||||
![]() ![]() ![]() ![]() | 0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() | 0..1 | CodeableConcept | Device detail Binding: (unbound) (example): A code that identifies the device detail. | |||||
![]() ![]() ![]() ![]() | 0..1 | Value of detail | ||||||
![]() ![]() ![]() ![]() ![]() | CodeableConcept | |||||||
![]() ![]() ![]() ![]() ![]() | Quantity | |||||||
![]() ![]() ![]() ![]() ![]() | Range | |||||||
![]() ![]() ![]() ![]() ![]() | boolean | |||||||
![]() ![]() ![]() | Σ | 1..1 | Reference(Patient | Group | Location | Device) | Focus of request | ||||
![]() ![]() ![]() | SΣ | 0..1 | Reference(US Core Encounter Profile) | Encounter motivating request | ||||
![]() ![]() ![]() | Σ | 0..1 | Desired time or schedule for use | |||||
![]() ![]() ![]() ![]() | dateTime | |||||||
![]() ![]() ![]() ![]() | Period | |||||||
![]() ![]() ![]() ![]() | Timing | |||||||
![]() ![]() ![]() | Σ | 0..1 | dateTime | When recorded | ||||
![]() ![]() ![]() | Σ | 0..1 | Reference(Device | Practitioner | PractitionerRole | Organization) | Who/what is requesting diagnostics | ||||
![]() ![]() ![]() | Σ | 0..1 | CodeableConcept | Filler role Binding: ParticipantRoles (example): Indicates specific responsibility of an individual within the care team, such as "Primary physician", "Team coordinator", "Caregiver", etc. | ||||
![]() ![]() ![]() | Σ | 0..1 | Reference(Practitioner | PractitionerRole | Organization | CareTeam | HealthcareService | Patient | Device | RelatedPerson) | Requested Filler | ||||
![]() ![]() ![]() | Σ | 0..* | CodeableConcept | Coded Reason for request Binding: Condition/Problem/DiagnosisCodes (example): Diagnosis or problem codes justifying the reason for requesting the device. | ||||
![]() ![]() ![]() | Σ | 0..* | Reference(Condition | Observation | DiagnosticReport | DocumentReference) | Linked Reason for request | ||||
![]() ![]() ![]() | 0..* | Reference(Coverage | ClaimResponse) | Associated insurance coverage | |||||
![]() ![]() ![]() | 0..* | Reference(Resource) | Additional clinical information | |||||
![]() ![]() ![]() | 0..* | Annotation | Notes or comments | |||||
![]() ![]() ![]() | 0..* | Reference(Provenance) | Request provenance | |||||
![]() |
Path | Conformance | ValueSet / Code | ||||
DeviceRequest.language | preferred | CommonLanguages
| ||||
DeviceRequest.status | required | RequestStatus | ||||
DeviceRequest.intent | required | Fixed Value: order | ||||
DeviceRequest.priority | required | RequestPriority | ||||
DeviceRequest.code[x] | example | FHIRDeviceTypes | ||||
DeviceRequest.parameter.code | example | |||||
DeviceRequest.performerType | example | ParticipantRoles | ||||
DeviceRequest.reasonCode | example | Condition/Problem/DiagnosisCodes |
Id | Grade | Path(s) | Details | Requirements |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
This structure is derived from DeviceRequest
Other representations of profile: CSV, Excel, Schematron
Notes
IG © 2020+ HL7. Package hl7.fhir.us.dme-orders#0.2.2 based on FHIR 4.0.1. Generated 2023-06-25
Links: Table of Contents |
QA Report
| Version History |
|
Propose a change