CodeX Radiation Therapy, published by HL7 International / Cross-Group Projects. This guide is not an authorized publication; it is the continuous build for version 2.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/codex-radiation-therapy/ and changes regularly. See the Directory of published versions
| Official URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-treated-phase | Version: 2.0.0 | |||
| Standards status: Trial-use Draft as of 2026-01-27 | Computable Name: RadiotherapyTreatedPhase | |||
| Other Identifiers: OID:2.16.840.1.113883.4.642.40.14.42.31 | ||||
A summary of a phase of radiotherapy treatment that has been delivered. A phase consists of a set of identical fractions. In this context, identical means that each fraction uses the same modality, technique, dose per fraction, and is applied to the same treatment volume or volumes. Because of their spatial relationship or the technique used, all treatment volumes do not necessarily receive the same total dose during a phase.
This profile is used to capture a phase of radiotherapy delivered to a patient. An overview of radiotherapy courses, phases, and treatment plans is shown here. The relationships between the various radiotherapy profiles are shown here.
Procedure resources whose code is SNOMEDCT 1222565005 (Radiotherapy treatment phase (regime/therapy)) MUST conform to this profile. Any resource intended to conform to this profile SHOULD populate meta.profile accordingly.
Usages:
You can also check for usages in the FHIR IG Statistics
Description Differentials, Snapshots, and other representations.
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
C | 0..* | USCoreProcedureProfile | An action that is being or was performed on a patient Constraints: us-core-7, codexrt-procedure-status, codexrt-motion-management-none, codexrt-free-breathing-technique, CategoryPreferred |
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() |
SC | 0..1 | (Complex) | Radiotherapy Modality And Technique Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality-and-technique Constraints: TechniquesForNeutronBeamModality, TechniquesForPhotonBeamModality, TechniquesForElectronBeamModality, TechniquesForCarbonIonBeamModality, TechniquesForProtonBeamModality, TechniquesForInternalRadiotherapyPermanentSeeds, TechniquesForLowDoseRateUsingTempRadSource, TechniquesForPulsedDoseRate, TechniquesForHighDoseRate, TechniquesForHighDoseRateElectronic, TechniquesForRadioPharmaceutical, ModalityTextRequiredForOther, TechniqueTextRequiredForOther |
![]() ![]() ![]() ![]() |
1..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() ![]() ![]() |
S | 1..1 | (Complex) | Radiotherapy Modality Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality |
![]() ![]() ![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality" | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Value of extension Binding: Radiotherapy Modality Value Set (required) | |
![]() ![]() ![]() ![]() ![]() |
S | 0..* | (Complex) | Radiotherapy Technique Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique |
![]() ![]() ![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique" | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Value of extension Binding: Radiotherapy Technique Value Set (required) | |
![]() ![]() ![]() ![]() ![]() |
S | 0..* | SimpleQuantity | Radiotherapy Energy or Isotope URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope Binding: Radiotherapy Energy Unit Value Set (required) |
![]() ![]() ![]() ![]() ![]() |
S | 0..* | CodeableConcept | Radiotherapy Treatment Applicator Type URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-treatment-applicator-type Binding: Brachytherapy Applicator Type Value Set (extensible) |
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality-and-technique" | |
![]() ![]() ![]() |
SC | 0..* | (Complex) | Image Guided Radiotherapy Modality URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-image-guided-radiotherapy-modality Constraints: IGRTEnergyAllowed |
![]() ![]() ![]() |
S | 0..1 | unsignedInt | Number of Fractions Delivered URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-fractions-delivered |
![]() ![]() ![]() |
S | 0..* | (Complex) | Radiotherapy Dose Delivered To Volume Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-dose-delivered-to-volume |
![]() ![]() ![]() ![]() |
1..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() ![]() ![]() |
S | 1..1 | Extension | Volume in the body where radiation was delivered |
![]() ![]() ![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | "volume" | |
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | Extension | Extension |
![]() ![]() ![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | "totalDoseDelivered" | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | Quantity | Value of extension Required Pattern: At least the following | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | decimal | Numerical value (with implicit precision) | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | code | < | <= | >= | > - how to understand the value | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unit representation | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Coded form of the unit Fixed Value: cGy | |
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | boolean | Point Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-point-dose |
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | boolean | Primary Plan Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-primary-plan-dose |
![]() ![]() ![]() ![]() ![]() |
S | 0..* | Quantity | Radiotherapy Biologically Effective Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiobiologic-metric |
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-dose-delivered-to-volume" | |
![]() ![]() ![]() |
S | 0..* | CodeableConcept | Reason for Revision or Adaptation URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-reason-for-revision-or-adaptation Binding: Radiotherapy Reason for Revision or Adaptation Value Set (extensible) |
![]() ![]() ![]() |
S | 0..* | CodeableConcept | Respiratory Motion Management URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management Binding: Radiotherapy Respiratory Motion Management Value Set (required) |
![]() ![]() ![]() |
S | 0..* | CodeableConcept | Free-Breathing Motion Management Technique URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique Binding: Radiotherapy Free-Breathing Motion Management Technique Value Set (extensible) |
![]() ![]() ![]() |
SC | 0..* | (Complex) | Intrafraction Verification URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-intrafraction-verification Constraints: IntrafractionVerificationQualifierAllowed |
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() |
SΣ | 2..* | Identifier | External Identifiers for this procedure Slice: Unordered, Open by value:use |
![]() ![]() ![]() |
SΣ | 1..1 | Identifier | The name that is displayed to the user. |
![]() ![]() ![]() ![]() |
?!Σ | 1..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Required Pattern: usual |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | The value that is unique Example General: 123456 |
![]() ![]() ![]() |
SΣ | 1..* | Identifier | A business identifier for the request or procedure, which is independent of its FHIR representation, such as a GUID or DICOM UID. |
![]() ![]() ![]() ![]() |
?!Σ | 1..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Required Pattern: official |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | The value that is unique Example General: 123456 |
![]() ![]() |
Σ | 0..* | Reference(US Core CarePlan Profile | US Core ServiceRequest Profile) | (USCDI) A request for this procedure Slice: Unordered, Open by profile:$this.resolve() |
![]() ![]() ![]() |
SΣ | 0..1 | Reference(Radiotherapy Planned Phase) | Radiotherapy Planned Phase that planned the treatment summarized in this Radiotherapy Treated Phase. |
![]() ![]() ![]() |
SΣ | 0..1 | Reference(Radiotherapy Phase Prescription) | Radiotherapy Phase Prescription that prescribed the treatment summarized in this Radiotherapy Treated Phase. |
![]() ![]() |
Σ | 0..* | Reference(Procedure | Observation | MedicationAdministration) | Part of referenced event Slice: Unordered, Open by profile:$this.resolve() |
![]() ![]() ![]() |
SΣ | 0..1 | Reference(Radiotherapy Course Summary) | Radiotherapy Course Summary that summarizes the course of which this Radiotherapy Treated Phase is a part. |
![]() ![]() |
?!SΣC | 1..1 | code | (USCDI) preparation | in-progress | not-done | on-hold | stopped | completed | entered-in-error | unknown Binding: EventStatus (required) |
![]() ![]() |
Σ | 1..1 | CodeableConcept | Classification of the procedure Binding: Radiotherapy Category Code Max Value Set (required) |
![]() ![]() |
SΣ | 1..1 | CodeableConcept | (USCDI) Identification of the procedure Binding: US Core Procedure Codes (extensible): Codes describing the type of Procedure Required Pattern: At least the following |
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |
![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |
![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 1222565005 | |
![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Radiotherapy treatment phase (regime/therapy) | |
![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |
![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |
![]() ![]() |
SΣ | 1..1 | Reference(Cancer Patient Profile) | (USCDI) Who the procedure was performed on |
![]() ![]() |
SΣC | 0..1 | Period | (USCDI) When the procedure was performed |
![]() ![]() ![]() |
SΣC | 0..1 | dateTime | The date and time when the first therapeutic radiation was delivered. |
![]() ![]() ![]() |
SΣC | 0..1 | dateTime | An end date is expected if the status is 'stopped' or 'completed' |
![]() ![]() |
SΣ | 0..* | BackboneElement | The people who performed the procedure Slice: Unordered, Open by profile:actor.resolve() |
![]() ![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
Σ | 1..1 | Reference(Practitioner | PractitionerRole | Organization | Patient | RelatedPerson | Device) | The reference to the practitioner |
![]() ![]() ![]() |
SΣ | 0..* | BackboneElement | The people who performed the procedure |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
Σ | 1..1 | Reference(US Core Organization Profile) | Organization that provided the radiotherapy treatment. |
![]() ![]() |
SΣ | 0..1 | Reference(US Core Location Profile) | Location where the radiotherapy treatment was performed. |
![]() ![]() |
SΣ | 0..* | CodeableConcept | Coded reason procedure performed Binding: Cancer Disorder Value Set (extensible) |
![]() ![]() |
SΣ | 0..* | Reference(Condition | Observation | Procedure | DiagnosticReport | DocumentReference) | The justification that the procedure was performed |
![]() ![]() |
SΣ | 0..* | CodeableConcept | All body structure(s) treated with this procedure. Binding: Radiotherapy Treatment Location Value Set (extensible) |
![]() ![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | General location qualifier (excluding laterality) for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-body-location-qualifier Binding: Body Location Qualifier Value Set (required) | |
![]() ![]() ![]() ![]() |
0..1 | CodeableConcept | Laterality qualifier for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-laterality-qualifier Binding: Laterality Qualifier Value Set (required) | |
![]() ![]() |
0..* | BackboneElement | Manipulated, implanted, or removed device Slice: Unordered, Open by profile:manipulated.resolve() | |
![]() ![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
1..1 | Reference(Device) | Device that was changed | |
![]() ![]() ![]() |
S | 0..* | BackboneElement | Radiotherapy Seed Device used as part of therapy. |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
1..1 | Reference(Radiotherapy Seed Device) | Device that was changed | |
![]() ![]() |
S | 0..* | Reference(Device | Medication | Substance) | Items used during procedure Slice: Unordered, Open by profile:$this.resolve() |
![]() ![]() ![]() |
S | 0..* | Reference(Radiotherapy Treatment Device) | Radiotherapy Treatment Device used as part of therapy. |
Documentation for this format | ||||
| Id | Grade | Path(s) | Description | Expression |
| CategoryPreferred | warning | Procedure | This code 108290001 is inactive and should be used only for backward compatibility. |
category.exists() and
category.coding.exists(
code = '108290001'
).not()
|
| IGRTEnergyAllowed | error | Procedure.extension:imageGuidedRadiotherapyModality | Energy is only allowed for X-Ray, Fluorograph, or CT Modalities. |
extension.where(url = 'energy').exists() implies
(extension.where(url = 'modality').exists() and
extension.where(url = 'modality').value.exists() and
extension.where(url = 'modality').value.coding.all(
(system = 'http://snomed.info/sct') and
(code = '168537006' or code = '44491008' or code = '77477000' or code = '717193008')
)
)
|
| IntrafractionVerificationQualifierAllowed | error | Procedure.extension:intrafractionVerification | Qualifier is only allowed for X-Ray procedure. |
extension.where(url = 'qualifier').exists() implies
(extension.where(url = 'procedure').exists() and
extension.where(url = 'procedure').value.exists() and
extension.where(url = 'procedure').value.coding.all(
(system = 'http://snomed.info/sct') and
(code = '168537006')
)
)
|
| ModalityTextRequiredForOther | error | Procedure.extension:modalityAndTechnique | Require a text literal for code other |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://terminology.hl7.org/CodeSystem/v3-NullFlavor' and code = 'UNC')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.text.exists()
|
| TechniqueTextRequiredForOther | error | Procedure.extension:modalityAndTechnique | Require a text literal for code other |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(system = 'http://terminology.hl7.org/CodeSystem/v3-NullFlavor' and code = 'UNC')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.text.exists()
|
| TechniquesForCarbonIonBeamModality | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Carbon Ion Beam Modality |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '1156505006')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '1156529004' or code = '1156528007' or code='1204242009')
|
| TechniquesForElectronBeamModality | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Electron Beam Modality |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '45643008')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '1162782007' or code = '1156526006' or code = '168524008' or code = '1163157007')
|
| TechniquesForHighDoseRate | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for High Dose Rate |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '394902000')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '384692006' or code = '1156382005' or code = '113120007' or code = ' 1156383000' or code = '384691004' or code = '168524008' or code = '14473006')
|
| TechniquesForHighDoseRateElectronic | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for High Dose Rate Electronic |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '438629002')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '384692006' or code = '1156382005' or code = '113120007' or code = '384691004' or code = '168524008' or code = '14473006')
|
| TechniquesForInternalRadiotherapyPermanentSeeds | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Internal Radiotherapy - Permanent Seeds |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '169359004')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '113120007')
|
| TechniquesForLowDoseRateUsingTempRadSource | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Low Dose Rate Using Temp Radiation Source |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '1156708005')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '384692006' or code = '113120007' or code = '14473006')
|
| TechniquesForNeutronBeamModality | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Neutron Beam Modality |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '80347004')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '169317000' or code = '1162782007')
|
| TechniquesForPhotonBeamModality | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Photon Beam Modality |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '1156506007')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '441799006' or code = '1156530009' or code = '1162782007' or code = '1156526006' or code = '168524008' or code = '1156530009' or code = '1163157007')
|
| TechniquesForProtonBeamModality | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Proton Beam Modality |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '10611004')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '1156529004' or code = '1156528007' or code = '1204242009' or code = '1163157007')
|
| TechniquesForPulsedDoseRate | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Pulsed Dose Rate |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '1156384006')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '384692006' or code = '113120007')
|
| TechniquesForRadioPharmaceutical | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Radiopharmaceutical |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '440252007')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '16560241000119104' or code = '1156383000' or code = '384692006' or code = '113120007')
|
| codexrt-free-breathing-technique | error | Procedure | The extension for the technique of free-breathing motion management is only allowed if motion management is free-breathing. SNOMEDCT code 721071000124104 is "External beam radiotherapy with free breathing (procedure)" |
extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique') implies extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management' and value.exists(coding.exists(code = '721071000124104' and system = 'http://snomed.info/sct')))
|
| codexrt-motion-management-none | error | Procedure | If the respiratory motion management is 'none', then no other respiratory motion management extensions are allowed. They would also be 'none' or contradict the 'none'. SNOMEDCT code 721031000124102 is "External beam radiotherapy without respiratory motion management (procedure)" |
extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management' and value.exists(coding.exists(code = '721031000124102' and system = 'http://snomed.info/sct'))) implies extension.where(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management').count() = 1
|
| codexrt-procedure-status | error | Procedure | Only the following status values are supported: in-progress | not-done | on-hold | stopped | completed |
status = 'in-progress' or status = 'not-done' or status = 'on-hold' or status = 'stopped' or status = 'completed'
|
| dom-2 | error | Procedure | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Procedure | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Procedure | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Procedure | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Procedure | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
| us-core-7 | error | Procedure | Performed SHALL be present if the status is 'completed' or 'in-progress' |
(status='completed' or status='in-progress') implies performed.exists()
|
| Path | Status | Usage | ValueSet | Version | Source |
| Procedure.category | Base | required | Radiotherapy Category Code Max Value Set | 📦2.0.0 | This IG |
| Procedure.reasonCode | Base | extensible | Cancer Disorder Value Set | 📦4.0.0 | minimal Common Oncology Data Elements v4.0 |
| Procedure.bodySite | Base | extensible | Radiotherapy Treatment Location Value Set | 📦4.0.0 | minimal Common Oncology Data Elements v4.0 |
| Id | Grade | Path(s) | Description | Expression |
| CategoryPreferred | warning | Procedure | This code 108290001 is inactive and should be used only for backward compatibility. |
category.exists() and
category.coding.exists(
code = '108290001'
).not()
|
| codexrt-free-breathing-technique | error | Procedure | The extension for the technique of free-breathing motion management is only allowed if motion management is free-breathing. SNOMEDCT code 721071000124104 is "External beam radiotherapy with free breathing (procedure)" |
extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique') implies extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management' and value.exists(coding.exists(code = '721071000124104' and system = 'http://snomed.info/sct')))
|
| codexrt-motion-management-none | error | Procedure | If the respiratory motion management is 'none', then no other respiratory motion management extensions are allowed. They would also be 'none' or contradict the 'none'. SNOMEDCT code 721031000124102 is "External beam radiotherapy without respiratory motion management (procedure)" |
extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management' and value.exists(coding.exists(code = '721031000124102' and system = 'http://snomed.info/sct'))) implies extension.where(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management').count() = 1
|
| codexrt-procedure-status | error | Procedure | Only the following status values are supported: in-progress | not-done | on-hold | stopped | completed |
status = 'in-progress' or status = 'not-done' or status = 'on-hold' or status = 'stopped' or status = 'completed'
|
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||
|---|---|---|---|---|---|---|---|---|
![]() |
C | 0..* | USCoreProcedureProfile | An action that is being or was performed on a patient Constraints: us-core-7, codexrt-procedure-status, codexrt-motion-management-none, codexrt-free-breathing-technique, CategoryPreferred | ||||
![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation This profile does not constrain the narrative in regard to content, language, or traceability to data elements | |||||
![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
SC | 0..1 | (Complex) | Radiotherapy Modality And Technique Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality-and-technique Constraints: TechniquesForNeutronBeamModality, TechniquesForPhotonBeamModality, TechniquesForElectronBeamModality, TechniquesForCarbonIonBeamModality, TechniquesForProtonBeamModality, TechniquesForInternalRadiotherapyPermanentSeeds, TechniquesForLowDoseRateUsingTempRadSource, TechniquesForPulsedDoseRate, TechniquesForHighDoseRate, TechniquesForHighDoseRateElectronic, TechniquesForRadioPharmaceutical, ModalityTextRequiredForOther, TechniqueTextRequiredForOther | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
1..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
S | 1..1 | (Complex) | Radiotherapy Modality Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality" | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Value of extension Binding: Radiotherapy Modality Value Set (required) | |||||
![]() ![]() ![]() ![]() ![]() |
S | 0..* | (Complex) | Radiotherapy Technique Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique" | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Value of extension Binding: Radiotherapy Technique Value Set (required) | |||||
![]() ![]() ![]() ![]() ![]() |
S | 0..* | SimpleQuantity | Radiotherapy Energy or Isotope URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope Binding: Radiotherapy Energy Unit Value Set (required) | ||||
![]() ![]() ![]() ![]() ![]() |
S | 0..* | CodeableConcept | Radiotherapy Treatment Applicator Type URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-treatment-applicator-type Binding: Brachytherapy Applicator Type Value Set (extensible) | ||||
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality-and-technique" | |||||
![]() ![]() ![]() |
SC | 0..* | (Complex) | Image Guided Radiotherapy Modality URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-image-guided-radiotherapy-modality Constraints: IGRTEnergyAllowed | ||||
![]() ![]() ![]() |
S | 0..1 | unsignedInt | Number of Fractions Delivered URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-fractions-delivered | ||||
![]() ![]() ![]() |
S | 0..* | (Complex) | Radiotherapy Dose Delivered To Volume Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-dose-delivered-to-volume | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
1..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
S | 1..1 | Extension | Volume in the body where radiation was delivered | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | "volume" | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | Reference(Radiotherapy Volume Profile) | Value of extension | |||||
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | Extension | Extension | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | "totalDoseDelivered" | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | Quantity | Value of extension Required Pattern: At least the following | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | decimal | Numerical value (with implicit precision) | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | code | < | <= | >= | > - how to understand the value | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unit representation | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Coded form of the unit Fixed Value: cGy | |||||
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | boolean | Point Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-point-dose | ||||
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | boolean | Primary Plan Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-primary-plan-dose | ||||
![]() ![]() ![]() ![]() ![]() |
S | 0..* | Quantity | Radiotherapy Biologically Effective Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiobiologic-metric | ||||
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-dose-delivered-to-volume" | |||||
![]() ![]() ![]() |
S | 0..* | CodeableConcept | Reason for Revision or Adaptation URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-reason-for-revision-or-adaptation Binding: Radiotherapy Reason for Revision or Adaptation Value Set (extensible) | ||||
![]() ![]() ![]() |
S | 0..* | CodeableConcept | Respiratory Motion Management URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management Binding: Radiotherapy Respiratory Motion Management Value Set (required) | ||||
![]() ![]() ![]() |
S | 0..* | CodeableConcept | Free-Breathing Motion Management Technique URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique Binding: Radiotherapy Free-Breathing Motion Management Technique Value Set (extensible) | ||||
![]() ![]() ![]() |
SC | 0..* | (Complex) | Intrafraction Verification URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-intrafraction-verification Constraints: IntrafractionVerificationQualifierAllowed | ||||
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() |
SΣ | 2..* | Identifier | External Identifiers for this procedure Slice: Unordered, Open by value:use | ||||
![]() ![]() ![]() |
SΣ | 1..1 | Identifier | The name that is displayed to the user. | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
?!Σ | 1..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Required Pattern: usual | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() ![]() |
SΣ | 1..* | Identifier | A business identifier for the request or procedure, which is independent of its FHIR representation, such as a GUID or DICOM UID. | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
?!Σ | 1..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Required Pattern: official | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() |
Σ | 0..* | canonical(PlanDefinition | ActivityDefinition | Measure | OperationDefinition | Questionnaire) | Instantiates FHIR protocol or definition | ||||
![]() ![]() |
Σ | 0..* | uri | Instantiates external protocol or definition | ||||
![]() ![]() |
Σ | 0..* | Reference(US Core CarePlan Profile | US Core ServiceRequest Profile) | (USCDI) A request for this procedure Slice: Unordered, Open by profile:$this.resolve() | ||||
![]() ![]() ![]() |
SΣ | 0..1 | Reference(Radiotherapy Planned Phase) | Radiotherapy Planned Phase that planned the treatment summarized in this Radiotherapy Treated Phase. | ||||
![]() ![]() ![]() |
SΣ | 0..1 | Reference(Radiotherapy Phase Prescription) | Radiotherapy Phase Prescription that prescribed the treatment summarized in this Radiotherapy Treated Phase. | ||||
![]() ![]() |
Σ | 0..* | Reference(Procedure | Observation | MedicationAdministration) | Part of referenced event Slice: Unordered, Open by profile:$this.resolve() | ||||
![]() ![]() ![]() |
SΣ | 0..1 | Reference(Radiotherapy Course Summary) | Radiotherapy Course Summary that summarizes the course of which this Radiotherapy Treated Phase is a part. | ||||
![]() ![]() |
?!SΣC | 1..1 | code | (USCDI) preparation | in-progress | not-done | on-hold | stopped | completed | entered-in-error | unknown Binding: EventStatus (required) | ||||
![]() ![]() |
Σ | 0..1 | CodeableConcept | Reason for current status Binding: ProcedureNotPerformedReason(SNOMED-CT) (example): A code that identifies the reason a procedure was not performed. | ||||
![]() ![]() |
Σ | 1..1 | CodeableConcept | Classification of the procedure Binding: Radiotherapy Category Code Max Value Set (required) | ||||
![]() ![]() |
SΣ | 1..1 | CodeableConcept | (USCDI) Identification of the procedure Binding: US Core Procedure Codes (extensible): Codes describing the type of Procedure Required Pattern: At least the following | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 1222565005 | |||||
![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Radiotherapy treatment phase (regime/therapy) | |||||
![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() |
SΣ | 1..1 | Reference(Cancer Patient Profile) | (USCDI) Who the procedure was performed on | ||||
![]() ![]() |
Σ | 0..1 | Reference(Encounter) | Encounter created as part of | ||||
![]() ![]() |
SΣC | 0..1 | Period | (USCDI) When the procedure was performed | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
SΣC | 0..1 | dateTime | The date and time when the first therapeutic radiation was delivered. | ||||
![]() ![]() ![]() |
SΣC | 0..1 | dateTime | An end date is expected if the status is 'stopped' or 'completed' | ||||
![]() ![]() |
Σ | 0..1 | Reference(Patient | RelatedPerson | Practitioner | PractitionerRole) | Who recorded the procedure | ||||
![]() ![]() |
Σ | 0..1 | Reference(Patient | RelatedPerson | Practitioner | PractitionerRole) | Person who asserts this procedure | ||||
![]() ![]() |
SΣ | 0..* | BackboneElement | The people who performed the procedure Slice: Unordered, Open by profile:actor.resolve() | ||||
![]() ![]() ![]() |
Content/Rules for all slices | |||||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | CodeableConcept | Type of performance Binding: ProcedurePerformerRoleCodes (example): A code that identifies the role of a performer of the procedure. | ||||
![]() ![]() ![]() ![]() |
Σ | 1..1 | Reference(Practitioner | PractitionerRole | Organization | Patient | RelatedPerson | Device) | The reference to the practitioner | ||||
![]() ![]() ![]() ![]() |
0..1 | Reference(Organization) | Organization the device or practitioner was acting for | |||||
![]() ![]() ![]() |
SΣ | 0..* | BackboneElement | The people who performed the procedure | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | CodeableConcept | Type of performance Binding: ProcedurePerformerRoleCodes (example): A code that identifies the role of a performer of the procedure. | ||||
![]() ![]() ![]() ![]() |
Σ | 1..1 | Reference(US Core Organization Profile) | Organization that provided the radiotherapy treatment. | ||||
![]() ![]() ![]() ![]() |
0..1 | Reference(Organization) | Organization the device or practitioner was acting for | |||||
![]() ![]() |
SΣ | 0..1 | Reference(US Core Location Profile) | Location where the radiotherapy treatment was performed. | ||||
![]() ![]() |
SΣ | 0..* | CodeableConcept | Coded reason procedure performed Binding: Cancer Disorder Value Set (extensible) | ||||
![]() ![]() |
SΣ | 0..* | Reference(Condition | Observation | Procedure | DiagnosticReport | DocumentReference) | The justification that the procedure was performed | ||||
![]() ![]() |
SΣ | 0..* | CodeableConcept | All body structure(s) treated with this procedure. Binding: Radiotherapy Treatment Location Value Set (extensible) | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | General location qualifier (excluding laterality) for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-body-location-qualifier Binding: Body Location Qualifier Value Set (required) | |||||
![]() ![]() ![]() ![]() |
0..1 | CodeableConcept | Laterality qualifier for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-laterality-qualifier Binding: Laterality Qualifier Value Set (required) | |||||
![]() ![]() ![]() |
Σ | 0..* | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() |
Σ | 0..1 | CodeableConcept | The result of procedure Binding: ProcedureOutcomeCodes(SNOMEDCT) (example): An outcome of a procedure - whether it was resolved or otherwise. | ||||
![]() ![]() |
0..* | Reference(DiagnosticReport | DocumentReference | Composition) | Any report resulting from the procedure | |||||
![]() ![]() |
0..* | CodeableConcept | Complication following the procedure Binding: Condition/Problem/DiagnosisCodes (example): Codes describing complications that resulted from a procedure. | |||||
![]() ![]() |
0..* | Reference(Condition) | A condition that is a result of the procedure | |||||
![]() ![]() |
0..* | CodeableConcept | Instructions for follow up Binding: ProcedureFollowUpCodes(SNOMEDCT) (example): Specific follow up required for a procedure e.g. removal of sutures. | |||||
![]() ![]() |
0..* | Annotation | Additional information about the procedure | |||||
![]() ![]() |
0..* | BackboneElement | Manipulated, implanted, or removed device Slice: Unordered, Open by profile:manipulated.resolve() | |||||
![]() ![]() ![]() |
Content/Rules for all slices | |||||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
0..1 | CodeableConcept | Kind of change to device Binding: ProcedureDeviceActionCodes (preferred): A kind of change that happened to the device during the procedure. | |||||
![]() ![]() ![]() ![]() |
1..1 | Reference(Device) | Device that was changed | |||||
![]() ![]() ![]() |
S | 0..* | BackboneElement | Radiotherapy Seed Device used as part of therapy. | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
0..1 | CodeableConcept | Kind of change to device Binding: ProcedureDeviceActionCodes (preferred): A kind of change that happened to the device during the procedure. | |||||
![]() ![]() ![]() ![]() |
1..1 | Reference(Radiotherapy Seed Device) | Device that was changed | |||||
![]() ![]() |
S | 0..* | Reference(Device | Medication | Substance) | Items used during procedure Slice: Unordered, Open by profile:$this.resolve() | ||||
![]() ![]() ![]() |
S | 0..* | Reference(Radiotherapy Treatment Device) | Radiotherapy Treatment Device used as part of therapy. | ||||
![]() ![]() |
0..* | CodeableConcept | Coded items used during the procedure Binding: FHIRDeviceTypes (example): Codes describing items used during a procedure. | |||||
Documentation for this format | ||||||||
| Id | Grade | Path(s) | Description | Expression |
| CategoryPreferred | warning | Procedure | This code 108290001 is inactive and should be used only for backward compatibility. |
category.exists() and
category.coding.exists(
code = '108290001'
).not()
|
| IGRTEnergyAllowed | error | Procedure.extension:imageGuidedRadiotherapyModality | Energy is only allowed for X-Ray, Fluorograph, or CT Modalities. |
extension.where(url = 'energy').exists() implies
(extension.where(url = 'modality').exists() and
extension.where(url = 'modality').value.exists() and
extension.where(url = 'modality').value.coding.all(
(system = 'http://snomed.info/sct') and
(code = '168537006' or code = '44491008' or code = '77477000' or code = '717193008')
)
)
|
| IntrafractionVerificationQualifierAllowed | error | Procedure.extension:intrafractionVerification | Qualifier is only allowed for X-Ray procedure. |
extension.where(url = 'qualifier').exists() implies
(extension.where(url = 'procedure').exists() and
extension.where(url = 'procedure').value.exists() and
extension.where(url = 'procedure').value.coding.all(
(system = 'http://snomed.info/sct') and
(code = '168537006')
)
)
|
| ModalityTextRequiredForOther | error | Procedure.extension:modalityAndTechnique | Require a text literal for code other |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://terminology.hl7.org/CodeSystem/v3-NullFlavor' and code = 'UNC')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.text.exists()
|
| TechniqueTextRequiredForOther | error | Procedure.extension:modalityAndTechnique | Require a text literal for code other |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(system = 'http://terminology.hl7.org/CodeSystem/v3-NullFlavor' and code = 'UNC')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.text.exists()
|
| TechniquesForCarbonIonBeamModality | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Carbon Ion Beam Modality |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '1156505006')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '1156529004' or code = '1156528007' or code='1204242009')
|
| TechniquesForElectronBeamModality | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Electron Beam Modality |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '45643008')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '1162782007' or code = '1156526006' or code = '168524008' or code = '1163157007')
|
| TechniquesForHighDoseRate | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for High Dose Rate |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '394902000')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '384692006' or code = '1156382005' or code = '113120007' or code = ' 1156383000' or code = '384691004' or code = '168524008' or code = '14473006')
|
| TechniquesForHighDoseRateElectronic | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for High Dose Rate Electronic |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '438629002')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '384692006' or code = '1156382005' or code = '113120007' or code = '384691004' or code = '168524008' or code = '14473006')
|
| TechniquesForInternalRadiotherapyPermanentSeeds | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Internal Radiotherapy - Permanent Seeds |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '169359004')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '113120007')
|
| TechniquesForLowDoseRateUsingTempRadSource | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Low Dose Rate Using Temp Radiation Source |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '1156708005')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '384692006' or code = '113120007' or code = '14473006')
|
| TechniquesForNeutronBeamModality | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Neutron Beam Modality |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '80347004')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '169317000' or code = '1162782007')
|
| TechniquesForPhotonBeamModality | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Photon Beam Modality |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '1156506007')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '441799006' or code = '1156530009' or code = '1162782007' or code = '1156526006' or code = '168524008' or code = '1156530009' or code = '1163157007')
|
| TechniquesForProtonBeamModality | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Proton Beam Modality |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '10611004')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '1156529004' or code = '1156528007' or code = '1204242009' or code = '1163157007')
|
| TechniquesForPulsedDoseRate | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Pulsed Dose Rate |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '1156384006')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '384692006' or code = '113120007')
|
| TechniquesForRadioPharmaceutical | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Radiopharmaceutical |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '440252007')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '16560241000119104' or code = '1156383000' or code = '384692006' or code = '113120007')
|
| codexrt-free-breathing-technique | error | Procedure | The extension for the technique of free-breathing motion management is only allowed if motion management is free-breathing. SNOMEDCT code 721071000124104 is "External beam radiotherapy with free breathing (procedure)" |
extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique') implies extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management' and value.exists(coding.exists(code = '721071000124104' and system = 'http://snomed.info/sct')))
|
| codexrt-motion-management-none | error | Procedure | If the respiratory motion management is 'none', then no other respiratory motion management extensions are allowed. They would also be 'none' or contradict the 'none'. SNOMEDCT code 721031000124102 is "External beam radiotherapy without respiratory motion management (procedure)" |
extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management' and value.exists(coding.exists(code = '721031000124102' and system = 'http://snomed.info/sct'))) implies extension.where(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management').count() = 1
|
| codexrt-procedure-status | error | Procedure | Only the following status values are supported: in-progress | not-done | on-hold | stopped | completed |
status = 'in-progress' or status = 'not-done' or status = 'on-hold' or status = 'stopped' or status = 'completed'
|
| dom-2 | error | Procedure | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Procedure | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Procedure | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Procedure | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Procedure | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
| us-core-7 | error | Procedure | Performed SHALL be present if the status is 'completed' or 'in-progress' |
(status='completed' or status='in-progress') implies performed.exists()
|
Summary
Mandatory: 9 elements
Must-Support: 34 elements
Prohibited: 1 element
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
Slices
This structure defines the following Slices:
Key Elements View
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
C | 0..* | USCoreProcedureProfile | An action that is being or was performed on a patient Constraints: us-core-7, codexrt-procedure-status, codexrt-motion-management-none, codexrt-free-breathing-technique, CategoryPreferred |
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() |
SC | 0..1 | (Complex) | Radiotherapy Modality And Technique Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality-and-technique Constraints: TechniquesForNeutronBeamModality, TechniquesForPhotonBeamModality, TechniquesForElectronBeamModality, TechniquesForCarbonIonBeamModality, TechniquesForProtonBeamModality, TechniquesForInternalRadiotherapyPermanentSeeds, TechniquesForLowDoseRateUsingTempRadSource, TechniquesForPulsedDoseRate, TechniquesForHighDoseRate, TechniquesForHighDoseRateElectronic, TechniquesForRadioPharmaceutical, ModalityTextRequiredForOther, TechniqueTextRequiredForOther |
![]() ![]() ![]() ![]() |
1..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() ![]() ![]() |
S | 1..1 | (Complex) | Radiotherapy Modality Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality |
![]() ![]() ![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality" | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Value of extension Binding: Radiotherapy Modality Value Set (required) | |
![]() ![]() ![]() ![]() ![]() |
S | 0..* | (Complex) | Radiotherapy Technique Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique |
![]() ![]() ![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique" | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Value of extension Binding: Radiotherapy Technique Value Set (required) | |
![]() ![]() ![]() ![]() ![]() |
S | 0..* | SimpleQuantity | Radiotherapy Energy or Isotope URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope Binding: Radiotherapy Energy Unit Value Set (required) |
![]() ![]() ![]() ![]() ![]() |
S | 0..* | CodeableConcept | Radiotherapy Treatment Applicator Type URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-treatment-applicator-type Binding: Brachytherapy Applicator Type Value Set (extensible) |
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality-and-technique" | |
![]() ![]() ![]() |
SC | 0..* | (Complex) | Image Guided Radiotherapy Modality URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-image-guided-radiotherapy-modality Constraints: IGRTEnergyAllowed |
![]() ![]() ![]() |
S | 0..1 | unsignedInt | Number of Fractions Delivered URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-fractions-delivered |
![]() ![]() ![]() |
S | 0..* | (Complex) | Radiotherapy Dose Delivered To Volume Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-dose-delivered-to-volume |
![]() ![]() ![]() ![]() |
1..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() ![]() ![]() |
S | 1..1 | Extension | Volume in the body where radiation was delivered |
![]() ![]() ![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | "volume" | |
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | Extension | Extension |
![]() ![]() ![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | "totalDoseDelivered" | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | Quantity | Value of extension Required Pattern: At least the following | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | decimal | Numerical value (with implicit precision) | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | code | < | <= | >= | > - how to understand the value | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unit representation | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Coded form of the unit Fixed Value: cGy | |
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | boolean | Point Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-point-dose |
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | boolean | Primary Plan Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-primary-plan-dose |
![]() ![]() ![]() ![]() ![]() |
S | 0..* | Quantity | Radiotherapy Biologically Effective Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiobiologic-metric |
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-dose-delivered-to-volume" | |
![]() ![]() ![]() |
S | 0..* | CodeableConcept | Reason for Revision or Adaptation URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-reason-for-revision-or-adaptation Binding: Radiotherapy Reason for Revision or Adaptation Value Set (extensible) |
![]() ![]() ![]() |
S | 0..* | CodeableConcept | Respiratory Motion Management URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management Binding: Radiotherapy Respiratory Motion Management Value Set (required) |
![]() ![]() ![]() |
S | 0..* | CodeableConcept | Free-Breathing Motion Management Technique URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique Binding: Radiotherapy Free-Breathing Motion Management Technique Value Set (extensible) |
![]() ![]() ![]() |
SC | 0..* | (Complex) | Intrafraction Verification URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-intrafraction-verification Constraints: IntrafractionVerificationQualifierAllowed |
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() |
SΣ | 2..* | Identifier | External Identifiers for this procedure Slice: Unordered, Open by value:use |
![]() ![]() ![]() |
SΣ | 1..1 | Identifier | The name that is displayed to the user. |
![]() ![]() ![]() ![]() |
?!Σ | 1..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Required Pattern: usual |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | The value that is unique Example General: 123456 |
![]() ![]() ![]() |
SΣ | 1..* | Identifier | A business identifier for the request or procedure, which is independent of its FHIR representation, such as a GUID or DICOM UID. |
![]() ![]() ![]() ![]() |
?!Σ | 1..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Required Pattern: official |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | The value that is unique Example General: 123456 |
![]() ![]() |
Σ | 0..* | Reference(US Core CarePlan Profile | US Core ServiceRequest Profile) | (USCDI) A request for this procedure Slice: Unordered, Open by profile:$this.resolve() |
![]() ![]() ![]() |
SΣ | 0..1 | Reference(Radiotherapy Planned Phase) | Radiotherapy Planned Phase that planned the treatment summarized in this Radiotherapy Treated Phase. |
![]() ![]() ![]() |
SΣ | 0..1 | Reference(Radiotherapy Phase Prescription) | Radiotherapy Phase Prescription that prescribed the treatment summarized in this Radiotherapy Treated Phase. |
![]() ![]() |
Σ | 0..* | Reference(Procedure | Observation | MedicationAdministration) | Part of referenced event Slice: Unordered, Open by profile:$this.resolve() |
![]() ![]() ![]() |
SΣ | 0..1 | Reference(Radiotherapy Course Summary) | Radiotherapy Course Summary that summarizes the course of which this Radiotherapy Treated Phase is a part. |
![]() ![]() |
?!SΣC | 1..1 | code | (USCDI) preparation | in-progress | not-done | on-hold | stopped | completed | entered-in-error | unknown Binding: EventStatus (required) |
![]() ![]() |
Σ | 1..1 | CodeableConcept | Classification of the procedure Binding: Radiotherapy Category Code Max Value Set (required) |
![]() ![]() |
SΣ | 1..1 | CodeableConcept | (USCDI) Identification of the procedure Binding: US Core Procedure Codes (extensible): Codes describing the type of Procedure Required Pattern: At least the following |
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |
![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |
![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 1222565005 | |
![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Radiotherapy treatment phase (regime/therapy) | |
![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |
![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |
![]() ![]() |
SΣ | 1..1 | Reference(Cancer Patient Profile) | (USCDI) Who the procedure was performed on |
![]() ![]() |
SΣC | 0..1 | Period | (USCDI) When the procedure was performed |
![]() ![]() ![]() |
SΣC | 0..1 | dateTime | The date and time when the first therapeutic radiation was delivered. |
![]() ![]() ![]() |
SΣC | 0..1 | dateTime | An end date is expected if the status is 'stopped' or 'completed' |
![]() ![]() |
SΣ | 0..* | BackboneElement | The people who performed the procedure Slice: Unordered, Open by profile:actor.resolve() |
![]() ![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
Σ | 1..1 | Reference(Practitioner | PractitionerRole | Organization | Patient | RelatedPerson | Device) | The reference to the practitioner |
![]() ![]() ![]() |
SΣ | 0..* | BackboneElement | The people who performed the procedure |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
Σ | 1..1 | Reference(US Core Organization Profile) | Organization that provided the radiotherapy treatment. |
![]() ![]() |
SΣ | 0..1 | Reference(US Core Location Profile) | Location where the radiotherapy treatment was performed. |
![]() ![]() |
SΣ | 0..* | CodeableConcept | Coded reason procedure performed Binding: Cancer Disorder Value Set (extensible) |
![]() ![]() |
SΣ | 0..* | Reference(Condition | Observation | Procedure | DiagnosticReport | DocumentReference) | The justification that the procedure was performed |
![]() ![]() |
SΣ | 0..* | CodeableConcept | All body structure(s) treated with this procedure. Binding: Radiotherapy Treatment Location Value Set (extensible) |
![]() ![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | General location qualifier (excluding laterality) for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-body-location-qualifier Binding: Body Location Qualifier Value Set (required) | |
![]() ![]() ![]() ![]() |
0..1 | CodeableConcept | Laterality qualifier for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-laterality-qualifier Binding: Laterality Qualifier Value Set (required) | |
![]() ![]() |
0..* | BackboneElement | Manipulated, implanted, or removed device Slice: Unordered, Open by profile:manipulated.resolve() | |
![]() ![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
1..1 | Reference(Device) | Device that was changed | |
![]() ![]() ![]() |
S | 0..* | BackboneElement | Radiotherapy Seed Device used as part of therapy. |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
1..1 | Reference(Radiotherapy Seed Device) | Device that was changed | |
![]() ![]() |
S | 0..* | Reference(Device | Medication | Substance) | Items used during procedure Slice: Unordered, Open by profile:$this.resolve() |
![]() ![]() ![]() |
S | 0..* | Reference(Radiotherapy Treatment Device) | Radiotherapy Treatment Device used as part of therapy. |
Documentation for this format | ||||
| Id | Grade | Path(s) | Description | Expression |
| CategoryPreferred | warning | Procedure | This code 108290001 is inactive and should be used only for backward compatibility. |
category.exists() and
category.coding.exists(
code = '108290001'
).not()
|
| IGRTEnergyAllowed | error | Procedure.extension:imageGuidedRadiotherapyModality | Energy is only allowed for X-Ray, Fluorograph, or CT Modalities. |
extension.where(url = 'energy').exists() implies
(extension.where(url = 'modality').exists() and
extension.where(url = 'modality').value.exists() and
extension.where(url = 'modality').value.coding.all(
(system = 'http://snomed.info/sct') and
(code = '168537006' or code = '44491008' or code = '77477000' or code = '717193008')
)
)
|
| IntrafractionVerificationQualifierAllowed | error | Procedure.extension:intrafractionVerification | Qualifier is only allowed for X-Ray procedure. |
extension.where(url = 'qualifier').exists() implies
(extension.where(url = 'procedure').exists() and
extension.where(url = 'procedure').value.exists() and
extension.where(url = 'procedure').value.coding.all(
(system = 'http://snomed.info/sct') and
(code = '168537006')
)
)
|
| ModalityTextRequiredForOther | error | Procedure.extension:modalityAndTechnique | Require a text literal for code other |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://terminology.hl7.org/CodeSystem/v3-NullFlavor' and code = 'UNC')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.text.exists()
|
| TechniqueTextRequiredForOther | error | Procedure.extension:modalityAndTechnique | Require a text literal for code other |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(system = 'http://terminology.hl7.org/CodeSystem/v3-NullFlavor' and code = 'UNC')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.text.exists()
|
| TechniquesForCarbonIonBeamModality | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Carbon Ion Beam Modality |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '1156505006')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '1156529004' or code = '1156528007' or code='1204242009')
|
| TechniquesForElectronBeamModality | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Electron Beam Modality |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '45643008')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '1162782007' or code = '1156526006' or code = '168524008' or code = '1163157007')
|
| TechniquesForHighDoseRate | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for High Dose Rate |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '394902000')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '384692006' or code = '1156382005' or code = '113120007' or code = ' 1156383000' or code = '384691004' or code = '168524008' or code = '14473006')
|
| TechniquesForHighDoseRateElectronic | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for High Dose Rate Electronic |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '438629002')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '384692006' or code = '1156382005' or code = '113120007' or code = '384691004' or code = '168524008' or code = '14473006')
|
| TechniquesForInternalRadiotherapyPermanentSeeds | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Internal Radiotherapy - Permanent Seeds |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '169359004')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '113120007')
|
| TechniquesForLowDoseRateUsingTempRadSource | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Low Dose Rate Using Temp Radiation Source |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '1156708005')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '384692006' or code = '113120007' or code = '14473006')
|
| TechniquesForNeutronBeamModality | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Neutron Beam Modality |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '80347004')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '169317000' or code = '1162782007')
|
| TechniquesForPhotonBeamModality | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Photon Beam Modality |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '1156506007')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '441799006' or code = '1156530009' or code = '1162782007' or code = '1156526006' or code = '168524008' or code = '1156530009' or code = '1163157007')
|
| TechniquesForProtonBeamModality | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Proton Beam Modality |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '10611004')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '1156529004' or code = '1156528007' or code = '1204242009' or code = '1163157007')
|
| TechniquesForPulsedDoseRate | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Pulsed Dose Rate |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '1156384006')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '384692006' or code = '113120007')
|
| TechniquesForRadioPharmaceutical | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Radiopharmaceutical |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '440252007')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '16560241000119104' or code = '1156383000' or code = '384692006' or code = '113120007')
|
| codexrt-free-breathing-technique | error | Procedure | The extension for the technique of free-breathing motion management is only allowed if motion management is free-breathing. SNOMEDCT code 721071000124104 is "External beam radiotherapy with free breathing (procedure)" |
extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique') implies extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management' and value.exists(coding.exists(code = '721071000124104' and system = 'http://snomed.info/sct')))
|
| codexrt-motion-management-none | error | Procedure | If the respiratory motion management is 'none', then no other respiratory motion management extensions are allowed. They would also be 'none' or contradict the 'none'. SNOMEDCT code 721031000124102 is "External beam radiotherapy without respiratory motion management (procedure)" |
extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management' and value.exists(coding.exists(code = '721031000124102' and system = 'http://snomed.info/sct'))) implies extension.where(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management').count() = 1
|
| codexrt-procedure-status | error | Procedure | Only the following status values are supported: in-progress | not-done | on-hold | stopped | completed |
status = 'in-progress' or status = 'not-done' or status = 'on-hold' or status = 'stopped' or status = 'completed'
|
| dom-2 | error | Procedure | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Procedure | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Procedure | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Procedure | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Procedure | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
| us-core-7 | error | Procedure | Performed SHALL be present if the status is 'completed' or 'in-progress' |
(status='completed' or status='in-progress') implies performed.exists()
|
Differential View
| Path | Status | Usage | ValueSet | Version | Source |
| Procedure.category | Base | required | Radiotherapy Category Code Max Value Set | 📦2.0.0 | This IG |
| Procedure.reasonCode | Base | extensible | Cancer Disorder Value Set | 📦4.0.0 | minimal Common Oncology Data Elements v4.0 |
| Procedure.bodySite | Base | extensible | Radiotherapy Treatment Location Value Set | 📦4.0.0 | minimal Common Oncology Data Elements v4.0 |
| Id | Grade | Path(s) | Description | Expression |
| CategoryPreferred | warning | Procedure | This code 108290001 is inactive and should be used only for backward compatibility. |
category.exists() and
category.coding.exists(
code = '108290001'
).not()
|
| codexrt-free-breathing-technique | error | Procedure | The extension for the technique of free-breathing motion management is only allowed if motion management is free-breathing. SNOMEDCT code 721071000124104 is "External beam radiotherapy with free breathing (procedure)" |
extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique') implies extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management' and value.exists(coding.exists(code = '721071000124104' and system = 'http://snomed.info/sct')))
|
| codexrt-motion-management-none | error | Procedure | If the respiratory motion management is 'none', then no other respiratory motion management extensions are allowed. They would also be 'none' or contradict the 'none'. SNOMEDCT code 721031000124102 is "External beam radiotherapy without respiratory motion management (procedure)" |
extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management' and value.exists(coding.exists(code = '721031000124102' and system = 'http://snomed.info/sct'))) implies extension.where(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management').count() = 1
|
| codexrt-procedure-status | error | Procedure | Only the following status values are supported: in-progress | not-done | on-hold | stopped | completed |
status = 'in-progress' or status = 'not-done' or status = 'on-hold' or status = 'stopped' or status = 'completed'
|
Snapshot ViewView
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||
|---|---|---|---|---|---|---|---|---|
![]() |
C | 0..* | USCoreProcedureProfile | An action that is being or was performed on a patient Constraints: us-core-7, codexrt-procedure-status, codexrt-motion-management-none, codexrt-free-breathing-technique, CategoryPreferred | ||||
![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation This profile does not constrain the narrative in regard to content, language, or traceability to data elements | |||||
![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
SC | 0..1 | (Complex) | Radiotherapy Modality And Technique Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality-and-technique Constraints: TechniquesForNeutronBeamModality, TechniquesForPhotonBeamModality, TechniquesForElectronBeamModality, TechniquesForCarbonIonBeamModality, TechniquesForProtonBeamModality, TechniquesForInternalRadiotherapyPermanentSeeds, TechniquesForLowDoseRateUsingTempRadSource, TechniquesForPulsedDoseRate, TechniquesForHighDoseRate, TechniquesForHighDoseRateElectronic, TechniquesForRadioPharmaceutical, ModalityTextRequiredForOther, TechniqueTextRequiredForOther | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
1..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
S | 1..1 | (Complex) | Radiotherapy Modality Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality" | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Value of extension Binding: Radiotherapy Modality Value Set (required) | |||||
![]() ![]() ![]() ![]() ![]() |
S | 0..* | (Complex) | Radiotherapy Technique Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique" | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Value of extension Binding: Radiotherapy Technique Value Set (required) | |||||
![]() ![]() ![]() ![]() ![]() |
S | 0..* | SimpleQuantity | Radiotherapy Energy or Isotope URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope Binding: Radiotherapy Energy Unit Value Set (required) | ||||
![]() ![]() ![]() ![]() ![]() |
S | 0..* | CodeableConcept | Radiotherapy Treatment Applicator Type URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-treatment-applicator-type Binding: Brachytherapy Applicator Type Value Set (extensible) | ||||
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality-and-technique" | |||||
![]() ![]() ![]() |
SC | 0..* | (Complex) | Image Guided Radiotherapy Modality URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-image-guided-radiotherapy-modality Constraints: IGRTEnergyAllowed | ||||
![]() ![]() ![]() |
S | 0..1 | unsignedInt | Number of Fractions Delivered URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-fractions-delivered | ||||
![]() ![]() ![]() |
S | 0..* | (Complex) | Radiotherapy Dose Delivered To Volume Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-dose-delivered-to-volume | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
1..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
S | 1..1 | Extension | Volume in the body where radiation was delivered | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | "volume" | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | Reference(Radiotherapy Volume Profile) | Value of extension | |||||
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | Extension | Extension | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | "totalDoseDelivered" | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | Quantity | Value of extension Required Pattern: At least the following | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | decimal | Numerical value (with implicit precision) | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | code | < | <= | >= | > - how to understand the value | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unit representation | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Coded form of the unit Fixed Value: cGy | |||||
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | boolean | Point Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-point-dose | ||||
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | boolean | Primary Plan Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-primary-plan-dose | ||||
![]() ![]() ![]() ![]() ![]() |
S | 0..* | Quantity | Radiotherapy Biologically Effective Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiobiologic-metric | ||||
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-dose-delivered-to-volume" | |||||
![]() ![]() ![]() |
S | 0..* | CodeableConcept | Reason for Revision or Adaptation URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-reason-for-revision-or-adaptation Binding: Radiotherapy Reason for Revision or Adaptation Value Set (extensible) | ||||
![]() ![]() ![]() |
S | 0..* | CodeableConcept | Respiratory Motion Management URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management Binding: Radiotherapy Respiratory Motion Management Value Set (required) | ||||
![]() ![]() ![]() |
S | 0..* | CodeableConcept | Free-Breathing Motion Management Technique URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique Binding: Radiotherapy Free-Breathing Motion Management Technique Value Set (extensible) | ||||
![]() ![]() ![]() |
SC | 0..* | (Complex) | Intrafraction Verification URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-intrafraction-verification Constraints: IntrafractionVerificationQualifierAllowed | ||||
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() |
SΣ | 2..* | Identifier | External Identifiers for this procedure Slice: Unordered, Open by value:use | ||||
![]() ![]() ![]() |
SΣ | 1..1 | Identifier | The name that is displayed to the user. | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
?!Σ | 1..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Required Pattern: usual | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() ![]() |
SΣ | 1..* | Identifier | A business identifier for the request or procedure, which is independent of its FHIR representation, such as a GUID or DICOM UID. | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
?!Σ | 1..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Required Pattern: official | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() |
Σ | 0..* | canonical(PlanDefinition | ActivityDefinition | Measure | OperationDefinition | Questionnaire) | Instantiates FHIR protocol or definition | ||||
![]() ![]() |
Σ | 0..* | uri | Instantiates external protocol or definition | ||||
![]() ![]() |
Σ | 0..* | Reference(US Core CarePlan Profile | US Core ServiceRequest Profile) | (USCDI) A request for this procedure Slice: Unordered, Open by profile:$this.resolve() | ||||
![]() ![]() ![]() |
SΣ | 0..1 | Reference(Radiotherapy Planned Phase) | Radiotherapy Planned Phase that planned the treatment summarized in this Radiotherapy Treated Phase. | ||||
![]() ![]() ![]() |
SΣ | 0..1 | Reference(Radiotherapy Phase Prescription) | Radiotherapy Phase Prescription that prescribed the treatment summarized in this Radiotherapy Treated Phase. | ||||
![]() ![]() |
Σ | 0..* | Reference(Procedure | Observation | MedicationAdministration) | Part of referenced event Slice: Unordered, Open by profile:$this.resolve() | ||||
![]() ![]() ![]() |
SΣ | 0..1 | Reference(Radiotherapy Course Summary) | Radiotherapy Course Summary that summarizes the course of which this Radiotherapy Treated Phase is a part. | ||||
![]() ![]() |
?!SΣC | 1..1 | code | (USCDI) preparation | in-progress | not-done | on-hold | stopped | completed | entered-in-error | unknown Binding: EventStatus (required) | ||||
![]() ![]() |
Σ | 0..1 | CodeableConcept | Reason for current status Binding: ProcedureNotPerformedReason(SNOMED-CT) (example): A code that identifies the reason a procedure was not performed. | ||||
![]() ![]() |
Σ | 1..1 | CodeableConcept | Classification of the procedure Binding: Radiotherapy Category Code Max Value Set (required) | ||||
![]() ![]() |
SΣ | 1..1 | CodeableConcept | (USCDI) Identification of the procedure Binding: US Core Procedure Codes (extensible): Codes describing the type of Procedure Required Pattern: At least the following | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 1222565005 | |||||
![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Radiotherapy treatment phase (regime/therapy) | |||||
![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() |
SΣ | 1..1 | Reference(Cancer Patient Profile) | (USCDI) Who the procedure was performed on | ||||
![]() ![]() |
Σ | 0..1 | Reference(Encounter) | Encounter created as part of | ||||
![]() ![]() |
SΣC | 0..1 | Period | (USCDI) When the procedure was performed | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
SΣC | 0..1 | dateTime | The date and time when the first therapeutic radiation was delivered. | ||||
![]() ![]() ![]() |
SΣC | 0..1 | dateTime | An end date is expected if the status is 'stopped' or 'completed' | ||||
![]() ![]() |
Σ | 0..1 | Reference(Patient | RelatedPerson | Practitioner | PractitionerRole) | Who recorded the procedure | ||||
![]() ![]() |
Σ | 0..1 | Reference(Patient | RelatedPerson | Practitioner | PractitionerRole) | Person who asserts this procedure | ||||
![]() ![]() |
SΣ | 0..* | BackboneElement | The people who performed the procedure Slice: Unordered, Open by profile:actor.resolve() | ||||
![]() ![]() ![]() |
Content/Rules for all slices | |||||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | CodeableConcept | Type of performance Binding: ProcedurePerformerRoleCodes (example): A code that identifies the role of a performer of the procedure. | ||||
![]() ![]() ![]() ![]() |
Σ | 1..1 | Reference(Practitioner | PractitionerRole | Organization | Patient | RelatedPerson | Device) | The reference to the practitioner | ||||
![]() ![]() ![]() ![]() |
0..1 | Reference(Organization) | Organization the device or practitioner was acting for | |||||
![]() ![]() ![]() |
SΣ | 0..* | BackboneElement | The people who performed the procedure | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | CodeableConcept | Type of performance Binding: ProcedurePerformerRoleCodes (example): A code that identifies the role of a performer of the procedure. | ||||
![]() ![]() ![]() ![]() |
Σ | 1..1 | Reference(US Core Organization Profile) | Organization that provided the radiotherapy treatment. | ||||
![]() ![]() ![]() ![]() |
0..1 | Reference(Organization) | Organization the device or practitioner was acting for | |||||
![]() ![]() |
SΣ | 0..1 | Reference(US Core Location Profile) | Location where the radiotherapy treatment was performed. | ||||
![]() ![]() |
SΣ | 0..* | CodeableConcept | Coded reason procedure performed Binding: Cancer Disorder Value Set (extensible) | ||||
![]() ![]() |
SΣ | 0..* | Reference(Condition | Observation | Procedure | DiagnosticReport | DocumentReference) | The justification that the procedure was performed | ||||
![]() ![]() |
SΣ | 0..* | CodeableConcept | All body structure(s) treated with this procedure. Binding: Radiotherapy Treatment Location Value Set (extensible) | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | General location qualifier (excluding laterality) for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-body-location-qualifier Binding: Body Location Qualifier Value Set (required) | |||||
![]() ![]() ![]() ![]() |
0..1 | CodeableConcept | Laterality qualifier for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-laterality-qualifier Binding: Laterality Qualifier Value Set (required) | |||||
![]() ![]() ![]() |
Σ | 0..* | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() |
Σ | 0..1 | CodeableConcept | The result of procedure Binding: ProcedureOutcomeCodes(SNOMEDCT) (example): An outcome of a procedure - whether it was resolved or otherwise. | ||||
![]() ![]() |
0..* | Reference(DiagnosticReport | DocumentReference | Composition) | Any report resulting from the procedure | |||||
![]() ![]() |
0..* | CodeableConcept | Complication following the procedure Binding: Condition/Problem/DiagnosisCodes (example): Codes describing complications that resulted from a procedure. | |||||
![]() ![]() |
0..* | Reference(Condition) | A condition that is a result of the procedure | |||||
![]() ![]() |
0..* | CodeableConcept | Instructions for follow up Binding: ProcedureFollowUpCodes(SNOMEDCT) (example): Specific follow up required for a procedure e.g. removal of sutures. | |||||
![]() ![]() |
0..* | Annotation | Additional information about the procedure | |||||
![]() ![]() |
0..* | BackboneElement | Manipulated, implanted, or removed device Slice: Unordered, Open by profile:manipulated.resolve() | |||||
![]() ![]() ![]() |
Content/Rules for all slices | |||||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
0..1 | CodeableConcept | Kind of change to device Binding: ProcedureDeviceActionCodes (preferred): A kind of change that happened to the device during the procedure. | |||||
![]() ![]() ![]() ![]() |
1..1 | Reference(Device) | Device that was changed | |||||
![]() ![]() ![]() |
S | 0..* | BackboneElement | Radiotherapy Seed Device used as part of therapy. | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
0..1 | CodeableConcept | Kind of change to device Binding: ProcedureDeviceActionCodes (preferred): A kind of change that happened to the device during the procedure. | |||||
![]() ![]() ![]() ![]() |
1..1 | Reference(Radiotherapy Seed Device) | Device that was changed | |||||
![]() ![]() |
S | 0..* | Reference(Device | Medication | Substance) | Items used during procedure Slice: Unordered, Open by profile:$this.resolve() | ||||
![]() ![]() ![]() |
S | 0..* | Reference(Radiotherapy Treatment Device) | Radiotherapy Treatment Device used as part of therapy. | ||||
![]() ![]() |
0..* | CodeableConcept | Coded items used during the procedure Binding: FHIRDeviceTypes (example): Codes describing items used during a procedure. | |||||
Documentation for this format | ||||||||
| Id | Grade | Path(s) | Description | Expression |
| CategoryPreferred | warning | Procedure | This code 108290001 is inactive and should be used only for backward compatibility. |
category.exists() and
category.coding.exists(
code = '108290001'
).not()
|
| IGRTEnergyAllowed | error | Procedure.extension:imageGuidedRadiotherapyModality | Energy is only allowed for X-Ray, Fluorograph, or CT Modalities. |
extension.where(url = 'energy').exists() implies
(extension.where(url = 'modality').exists() and
extension.where(url = 'modality').value.exists() and
extension.where(url = 'modality').value.coding.all(
(system = 'http://snomed.info/sct') and
(code = '168537006' or code = '44491008' or code = '77477000' or code = '717193008')
)
)
|
| IntrafractionVerificationQualifierAllowed | error | Procedure.extension:intrafractionVerification | Qualifier is only allowed for X-Ray procedure. |
extension.where(url = 'qualifier').exists() implies
(extension.where(url = 'procedure').exists() and
extension.where(url = 'procedure').value.exists() and
extension.where(url = 'procedure').value.coding.all(
(system = 'http://snomed.info/sct') and
(code = '168537006')
)
)
|
| ModalityTextRequiredForOther | error | Procedure.extension:modalityAndTechnique | Require a text literal for code other |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://terminology.hl7.org/CodeSystem/v3-NullFlavor' and code = 'UNC')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.text.exists()
|
| TechniqueTextRequiredForOther | error | Procedure.extension:modalityAndTechnique | Require a text literal for code other |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(system = 'http://terminology.hl7.org/CodeSystem/v3-NullFlavor' and code = 'UNC')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.text.exists()
|
| TechniquesForCarbonIonBeamModality | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Carbon Ion Beam Modality |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '1156505006')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '1156529004' or code = '1156528007' or code='1204242009')
|
| TechniquesForElectronBeamModality | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Electron Beam Modality |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '45643008')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '1162782007' or code = '1156526006' or code = '168524008' or code = '1163157007')
|
| TechniquesForHighDoseRate | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for High Dose Rate |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '394902000')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '384692006' or code = '1156382005' or code = '113120007' or code = ' 1156383000' or code = '384691004' or code = '168524008' or code = '14473006')
|
| TechniquesForHighDoseRateElectronic | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for High Dose Rate Electronic |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '438629002')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '384692006' or code = '1156382005' or code = '113120007' or code = '384691004' or code = '168524008' or code = '14473006')
|
| TechniquesForInternalRadiotherapyPermanentSeeds | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Internal Radiotherapy - Permanent Seeds |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '169359004')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '113120007')
|
| TechniquesForLowDoseRateUsingTempRadSource | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Low Dose Rate Using Temp Radiation Source |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '1156708005')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '384692006' or code = '113120007' or code = '14473006')
|
| TechniquesForNeutronBeamModality | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Neutron Beam Modality |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '80347004')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '169317000' or code = '1162782007')
|
| TechniquesForPhotonBeamModality | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Photon Beam Modality |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '1156506007')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '441799006' or code = '1156530009' or code = '1162782007' or code = '1156526006' or code = '168524008' or code = '1156530009' or code = '1163157007')
|
| TechniquesForProtonBeamModality | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Proton Beam Modality |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '10611004')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '1156529004' or code = '1156528007' or code = '1204242009' or code = '1163157007')
|
| TechniquesForPulsedDoseRate | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Pulsed Dose Rate |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '1156384006')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '384692006' or code = '113120007')
|
| TechniquesForRadioPharmaceutical | error | Procedure.extension:modalityAndTechnique | Allowed Techniques for Radiopharmaceutical |
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality').value.coding.exists(system = 'http://snomed.info/sct' and code = '440252007')
implies
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.exists() and
extension.where(url = 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique').value.coding.exists(code = 'UNC' or code = '16560241000119104' or code = '1156383000' or code = '384692006' or code = '113120007')
|
| codexrt-free-breathing-technique | error | Procedure | The extension for the technique of free-breathing motion management is only allowed if motion management is free-breathing. SNOMEDCT code 721071000124104 is "External beam radiotherapy with free breathing (procedure)" |
extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique') implies extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management' and value.exists(coding.exists(code = '721071000124104' and system = 'http://snomed.info/sct')))
|
| codexrt-motion-management-none | error | Procedure | If the respiratory motion management is 'none', then no other respiratory motion management extensions are allowed. They would also be 'none' or contradict the 'none'. SNOMEDCT code 721031000124102 is "External beam radiotherapy without respiratory motion management (procedure)" |
extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management' and value.exists(coding.exists(code = '721031000124102' and system = 'http://snomed.info/sct'))) implies extension.where(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management').count() = 1
|
| codexrt-procedure-status | error | Procedure | Only the following status values are supported: in-progress | not-done | on-hold | stopped | completed |
status = 'in-progress' or status = 'not-done' or status = 'on-hold' or status = 'stopped' or status = 'completed'
|
| dom-2 | error | Procedure | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Procedure | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Procedure | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Procedure | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Procedure | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
| us-core-7 | error | Procedure | Performed SHALL be present if the status is 'completed' or 'in-progress' |
(status='completed' or status='in-progress') implies performed.exists()
|
Summary
Mandatory: 9 elements
Must-Support: 34 elements
Prohibited: 1 element
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
Slices
This structure defines the following Slices:
Other representations of profile: CSV, Excel, Schematron