CodeX Radiation Therapy, published by HL7 International / Cross-Group Projects. This guide is not an authorized publication; it is the continuous build for version 2.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/codex-radiation-therapy/ and changes regularly. See the Directory of published versions
| Official URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope | Version: 2.0.0 | |||
| Standards status: Trial-use Active as of 2026-01-27 | Computable Name: RadiotherapyEnergyOrIsotope | |||
| Other Identifiers: OID:2.16.840.1.113883.4.642.40.14.42.13 | ||||
The radiation energy used for radiotherapy. The energy spectrum is characterized by the maximum energy, the maximum acceleration voltage, or the used isotope.
Context of Use
This extension may be used on the following element(s)
Procedure
ServiceRequest
ActivityDefinition
Device
Usage info
Usages:
You can also check for usages in the FHIR IG Statistics
Description Differentials, Snapshots, and other representations.
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | Extension | Radiotherapy Energy or Isotope | |
![]() ![]() |
0..0 | Extension | ||
![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope" | |
![]() ![]() |
1..1 | Value of extension Slice: Unordered, Open by type:$this | ||
![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() |
Quantity(SimpleQuantity) | |||
![]() ![]() ![]() |
0..1 | SimpleQuantity | The spectrum of radiation energy characterized by a maximum value.
For electrons, the maximum energy is given in MeV. For photons, the maximum acceleration voltage is given in MV or kV, although those are not units of energy. Binding: Radiotherapy Energy Unit Value Set (required) | |
![]() ![]() ![]() ![]() |
1..1 | decimal | Numerical value (with implicit precision) | |
![]() ![]() ![]() ![]() |
1..1 | uri | System that defines coded unit form | |
![]() ![]() ![]() ![]() |
1..1 | code | Coded form of the unit | |
![]() ![]() ![]() |
0..1 | CodeableConcept | The isotope used for radiotherapy. Binding: Radiotherapy Isotope Value Set (extensible) | |
Documentation for this format | ||||
| Path | Status | Usage | ValueSet | Version | Source |
| Extension.value[x]:valueQuantity | Base | required | Radiotherapy Energy Unit Value Set | 📦2.0.0 | This IG |
| Extension.value[x]:valueCodeableConcept | Base | extensible | Radiotherapy Isotope Value Set | 📦2.0.0 | This IG |
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | Extension | Radiotherapy Energy or Isotope | |
![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||
![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope" | |
![]() ![]() |
1..1 | Value of extension Slice: Unordered, Closed by type:$this | ||
![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() |
Quantity(SimpleQuantity) | |||
![]() ![]() ![]() |
0..1 | SimpleQuantity | The spectrum of radiation energy characterized by a maximum value.
For electrons, the maximum energy is given in MeV. For photons, the maximum acceleration voltage is given in MV or kV, although those are not units of energy. Binding: Radiotherapy Energy Unit Value Set (required) | |
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
![]() ![]() ![]() ![]() |
Σ | 1..1 | decimal | Numerical value (with implicit precision) |
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Unit representation |
![]() ![]() ![]() ![]() |
ΣC | 1..1 | uri | System that defines coded unit form |
![]() ![]() ![]() ![]() |
Σ | 1..1 | code | Coded form of the unit |
![]() ![]() ![]() |
0..1 | CodeableConcept | The isotope used for radiotherapy. Binding: Radiotherapy Isotope Value Set (extensible) | |
Documentation for this format | ||||
| Path | Status | Usage | ValueSet | Version | Source |
| Extension.value[x]:valueQuantity | Base | required | Radiotherapy Energy Unit Value Set | 📦2.0.0 | This IG |
| Extension.value[x]:valueCodeableConcept | Base | extensible | Radiotherapy Isotope Value Set | 📦2.0.0 | This IG |
| Id | Grade | Path(s) | Description | Expression |
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
Differential ViewDifferential View
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | Extension | Radiotherapy Energy or Isotope | |
![]() ![]() |
0..0 | Extension | ||
![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope" | |
![]() ![]() |
1..1 | Value of extension Slice: Unordered, Open by type:$this | ||
![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() |
Quantity(SimpleQuantity) | |||
![]() ![]() ![]() |
0..1 | SimpleQuantity | The spectrum of radiation energy characterized by a maximum value.
For electrons, the maximum energy is given in MeV. For photons, the maximum acceleration voltage is given in MV or kV, although those are not units of energy. Binding: Radiotherapy Energy Unit Value Set (required) | |
![]() ![]() ![]() ![]() |
1..1 | decimal | Numerical value (with implicit precision) | |
![]() ![]() ![]() ![]() |
1..1 | uri | System that defines coded unit form | |
![]() ![]() ![]() ![]() |
1..1 | code | Coded form of the unit | |
![]() ![]() ![]() |
0..1 | CodeableConcept | The isotope used for radiotherapy. Binding: Radiotherapy Isotope Value Set (extensible) | |
Documentation for this format | ||||
| Path | Status | Usage | ValueSet | Version | Source |
| Extension.value[x]:valueQuantity | Base | required | Radiotherapy Energy Unit Value Set | 📦2.0.0 | This IG |
| Extension.value[x]:valueCodeableConcept | Base | extensible | Radiotherapy Isotope Value Set | 📦2.0.0 | This IG |
Snapshot View
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | Extension | Radiotherapy Energy or Isotope | |
![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||
![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope" | |
![]() ![]() |
1..1 | Value of extension Slice: Unordered, Closed by type:$this | ||
![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() |
Quantity(SimpleQuantity) | |||
![]() ![]() ![]() |
0..1 | SimpleQuantity | The spectrum of radiation energy characterized by a maximum value.
For electrons, the maximum energy is given in MeV. For photons, the maximum acceleration voltage is given in MV or kV, although those are not units of energy. Binding: Radiotherapy Energy Unit Value Set (required) | |
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
![]() ![]() ![]() ![]() |
Σ | 1..1 | decimal | Numerical value (with implicit precision) |
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Unit representation |
![]() ![]() ![]() ![]() |
ΣC | 1..1 | uri | System that defines coded unit form |
![]() ![]() ![]() ![]() |
Σ | 1..1 | code | Coded form of the unit |
![]() ![]() ![]() |
0..1 | CodeableConcept | The isotope used for radiotherapy. Binding: Radiotherapy Isotope Value Set (extensible) | |
Documentation for this format | ||||
| Path | Status | Usage | ValueSet | Version | Source |
| Extension.value[x]:valueQuantity | Base | required | Radiotherapy Energy Unit Value Set | 📦2.0.0 | This IG |
| Extension.value[x]:valueCodeableConcept | Base | extensible | Radiotherapy Isotope Value Set | 📦2.0.0 | This IG |
| Id | Grade | Path(s) | Description | Expression |
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
Other representations of profile: CSV, Excel, Schematron