FHIR CI-Build

This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions

Example SpecimenDefinition/7 (Narrative)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: No defined compartments

This is the narrative for the resource. See also the XML, JSON or Turtle format. This example conforms to the profile SpecimenDefinition.


Generated Narrative: SpecimenDefinition 7

StructureDefinition Work Group: oo

url: http://example-lab.com/specdef/123455

identifier: 123455

title: Venous blood specimen

status: active

experimental: true

publisher: HL7 International / Orders and Observations

contact: http://www.hl7.org/Special/committees/orders

typeCollected: Venous blood specimen (specimen)

patientPreparation: no strict fasting

typeTested

isDerived: true

type: Serum specimen (specimen)

preference: preferred

Containers

-MaterialTypeCapMinimumVolume[x]
* glass Evacuated blood collection tube with thrombin and clot activator and gel separator yellow cap 2 ml (Details: UCUM codemL = 'mL')

handling

temperatureQualifier: room temperature

temperatureRange: 15-25 °C

MaxDurations

-ValueSystemCode
* 12 http://unitsofmeasure.org h

 

 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.